- ICH GCP
- US Clinical Trials Registry
- Klinisk utprøving NCT07957807
3D Video to Measure Breathing and Breathing-Muscle Activity (KINEVENT)
Non-invasive Measurement of Tidal Volume and Inspiratory Muscle Recruitment Using Three-dimensional Video in Healthy Volunteers Under Incremental Inspiratory Loading: a Pilot Agreement Study
Doctors often need to know how well a patient is breathing. Two things matter: how much air a person moves with each breath, and how hard the breathing muscles are working. Today, measuring these usually requires devices placed on or inside the body, which can be uncomfortable and are not always suitable at the bedside.
This study tests a new way to measure breathing without touching the body. A set of cameras films the surface of the chest and neck and builds a three-dimensional image of how they move during breathing. A computer uses these movements to estimate the amount of air breathed and to detect when the breathing muscles are being used.
The purpose of this study is to check whether the camera-based method is accurate. To do this, the researchers compare it with standard breathing measurements in healthy adult volunteers. During a single session, volunteers breathe normally and then breathe against increasing resistance, which makes breathing a little harder, while the cameras and the standard devices record at the same time.
The study will include 10 healthy volunteers (5 women and 5 men). It does not involve any treatment, and no results are expected to directly benefit the participants. If the method proves accurate, it could later be tested in patients to help monitor breathing in intensive care.
Studieoversikt
Status
Forhold
Intervensjon / Behandling
Studietype
Registrering (Antatt)
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiekontakt
- Navn: Guillaume Dumas, MD, PhD
- Telefonnummer: +33 4 76 76 87 79
- E-post: GDumasgalant@chu-grenoble.fr
Studer Kontakt Backup
- Navn: EVA LATCHIMY
- Telefonnummer: +33 0476767109
- E-post: MELatchimy@chu-grenoble.fr
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Beskrivelse
Inclusion Criteria:
- Adult aged 18 years or older
- No known respiratory, cardiovascular, or neurological disease
- Able to understand and perform the requested breathing maneuvers
- Affiliated with a social security scheme (or beneficiary of one)
- Written informed consent signed
Exclusion Criteria:
- Respiratory, thoracic, or chest wall disease or history
- Body mass index ≥ 30 kg/m²
- Inability to perform the maneuvers (understanding, cooperation)
- Pregnant or breastfeeding woman
- Person deprived of liberty by judicial or administrative decision
- Adult under a legal protection measure
- Person unable to express consent
- Participation in an exclusion period of another study
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Grunnvitenskap
- Tildeling: N/A
- Intervensjonsmodell: Enkeltgruppeoppdrag
- Masking: Ingen (Open Label)
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Eksperimentell: Healthy volunteers - incremental inspiratory loading
Healthy adult volunteers undergo a single measurement session. Breathing is recorded simultaneously by a markerless three-dimensional multi-camera system (surface reconstruction of the torso), a calibrated spirometer (reference tidal volume), and surface electromyography of the sternocleidomastoid and of the diaphragmatic zone of apposition. After a quiet-breathing reference period, participants breathe against stepwise increasing inspiratory resistances, with a Borg dyspnea rating at each step. Video-estimated tidal volume is compared with spirometry (primary outcome: agreement), and video-derived surface deformation indices are compared with surface electromyography. No treatment is given; there is no individual benefit expected. |
A markerless multi-camera system reconstructs the three-dimensional surface of the torso without contact or skin markers. Surface deformations over the respiratory cycle are used to estimate tidal volume and to derive regional indices of respiratory muscle recruitment (cervical region and lower thoraco-abdominal region). During a single session, recordings are acquired simultaneously with a calibrated spirometer (reference tidal volume) and with surface electromyography of the sternocleidomastoid and of the diaphragmatic zone of apposition. The video system is calibrated beforehand on a bench using an artificial lung delivering known volumes. The device is used for measurement only, is non-invasive, and emits no radiation. |
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Agreement between video-estimated and spirometry-measured tidal volume (bias)
Tidsramme: During the single measurement session (approximately 2 hours)
|
Mean difference (bias, in milliliters) between tidal volume estimated by the three-dimensional video system and tidal volume measured by calibrated spirometry (reference) .The 95% limits of agreement are reported as a supporting measure. |
During the single measurement session (approximately 2 hours)
|
Sekundære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Error between video and spirometry volume-time curves
Tidsramme: During the single measurement session (approximately 2 hours)
|
Normalized root mean square error (nRMSE, dimensionless) between the continuous volume-time curve from the three-dimensional video system and calibrated spirometry (reference). |
During the single measurement session (approximately 2 hours)
|
|
Correlation between cervical-region video signal and sternocleidomastoid surface EMG
Tidsramme: During the single measurement session (approximately 2 hours)
|
Repeated-measures correlation coefficient (rmcorr, dimensionless, range -1 to 1) between the cervical-region video signal (three-dimensional video system) and the normalized surface electromyography amplitude of the sternocleidomastoid muscle (% of maximal activation). |
During the single measurement session (approximately 2 hours)
|
|
Robustness of video-spirometry agreement and of video volume measurement across inspiratory load levels
Tidsramme: During the single measurement session (approximately 2 hours)
|
Mean difference (bias, in milliliters) between video-estimated and spirometry-measured tidal volume, reported separately for each inspiratory load level. The 95% limits of agreement are reported as a supporting measure. |
During the single measurement session (approximately 2 hours)
|
Samarbeidspartnere og etterforskere
Sponsor
Samarbeidspartnere
Etterforskere
- Studieleder: Guillaume Dumas, MD, PhD, University Grenoble Alps
Studierekorddatoer
Studer hoveddatoer
Studiestart (Antatt)
Primær fullføring (Antatt)
Studiet fullført (Antatt)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Nøkkelord
Andre studie-ID-numre
- 38RC26.0329
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .