- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT00754728
"JACTAX" Trial Drug Eluting Stent Trial
February 28, 2017 updated by: Boston Scientific Corporation
Prospective, multi-center, non-randomized registry.
100 patients will be enrolled at up to 10 clinical sites in Europe.
The results of this study will be compared to the TAXUS™ ATLAS clinical trial to evaluate the safety of the product.
Study Overview
Detailed Description
The JACTAX Drug Eluting Stent has been designed to minimize the amount of polymer in contact with the vessel surface, thus potentially reducing the incidence of untoward side effects.
The Juxtaposed Ablumenal Coating Process is capable of exclusive coating on the ablumenal side of pre-mounted bare metal stents.
Juxtaposed Ablumenal Coating is a proprietary formulation containing a bioerodable polymer.
The combination of the Juxtaposed Ablumenal Coating Process and Juxtaposed Ablumenal Coating create a unique microstructure surface, and reduces the amount of required polymer.
Study Type
Interventional
Enrollment (Actual)
103
Phase
- Not Applicable
Contacts and Locations
This section provides the contact details for those conducting the study, and information on where this study is being conducted.
Study Locations
-
-
-
Bonn, Germany
- Universitatsklinikum Bonn
-
Hamburg, Germany
- Hamburg University Cardiovascular Center
-
Siegburg, Germany
- Helios Klinikum
-
Trier, Germany
- Krankehaus der Barmherzigen Bruder
-
-
-
-
-
Southampton, United Kingdom
- Southampton NHS
-
-
Participation Criteria
Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.
Eligibility Criteria
Ages Eligible for Study
18 years and older (Adult, Older Adult)
Accepts Healthy Volunteers
No
Genders Eligible for Study
All
Description
General Inclusion Criteria:
- Patient is ≥ 18 years of age
- Patient is eligible for percutaneous coronary intervention (PCI)
- Patient demonstrates LVEF of ≥ 25%
- Patient or legal guardian understands and agrees to comply with all specified study requirements and provides written informed consent to this effect
Angiographic Inclusion Criteria:
- Target lesion is de novo native coronary artery lesion (i.e., a coronary lesion not previously treated)
- Target lesion can be treated with one stent, with overlap onto the healthy tissue, as specified in visual estimate guidelines.Max lesion length is 20 mm(i.e. approximately 4mm on each side, based on visual estimate and available stent lengths)
- Reference vessel diameter is between 2.75mm and 3.5 mm
- Study lesion diameter stenosis is ≥70%
- Study lesion has been successfully pre-dilated
- Patients enrolled for treatment may demonstrate multiple lesions in target vessel. However lesions must be covered completely by one study stent
- Patient must have no more than two lesions requiring treatment. These lesions must be in different vessel distributions. For example, if the target lesion is in the LAD, then the non target lesion must be present in either the circumflex or RCA. The non-study lesion may not be in a branch vessel or distal to the target vessel location
- The non target lesion must be successfully treated prior to the treatment of the target lesion. The non target lesion must be treated with either a TAXUS paclitaxel eluting stent or a bare metal stent.
General Exclusion Criteria:
- The patient has a life expectancy of less than 24 months due to another medical condition
- Patient has a history of hypersensitivity to paclitaxel or structurally related compounds
- Patient exhibits cardiogenic shock (systolic pressure <80 mmHg and PCWP> 20mm Hg or cardiac index <1.8 liters/m or intra-aortic balloon pump or intravenous inotropes are needed to maintain a systolic pressure >80 mmHg) for any time within 24 hours prior to index procedure
- Patient demonstrates evidence of acute or chronic renal dysfunction (serum creatinine >2.0 mg/dl or 177umol/l)
- Planned cardiac surgery procedure <= 9 months post index procedure
- Patient demonstrates evidence of a myocardial infarction (elevated CK, CKMB or Troponin) within 72 hours prior to index procedure and/or CK> 2X local lab's ULN, unless CK-MB is <2X ULN
- Patient exhibits acute ST segment elevation MI (STEMI) within 72 hours prior to the index procedure
- CVA including stroke or TIA within 3 months
- Patient demonstrates evidence of leukopenia
- Patient demonstrates evidence of thrombocytopenia or thrombocytosis
- Patient is contraindicated to ASA, clopidogrel or ticlopidine
- Patient is currently on warfarin, or possibility of treatment with warfarin during the following 6 months post index procedure
- Patient has been treated with paclitaxel or other chemotherapeutic agents within 12 months prior to planned index procedure
- Anticipated treatment with paclitaxel or oral rapamycin during any period in the 9 months after the index procedure
- Patient has received a drug eluting stent within 12 months prior to planned index procedure
- Previous or planned treatment with intravascular brachytherapy in target vessel
- Known allergy to stainless steel
- Male or female with known intention to procreate within 3 months after the index procedure
- Female of childbearing potential with a positive pregnancy test within 7 days before the index procedure, or lactating or intends to become pregnant during the 12 months post index procedure
Angiographic Exclusion Criteria
- Evidence of probable or definite thrombus of the study vessel, based on angiography or IVUS
- Study lesion is totally occluded (TIMI flow <= 1) either at baseline or before pre-dilatation
- Study lesion, or the study vessel proximal to the study lesion is moderately or severely calcified by visual estimate
- Study lesion is ostial in location (within 3.0 mm of vessel origin)
- Study lesion involving arterial segments with highly tortuous anatomy or where lesion is located within or distal to a >60 degree bend in the vessel
- Study lesion involves a bifurcation with a diseased (>50% stenotic) branch vessel >2.0 mm in diameter
- Left main coronary artery disease (stenosis >50%) branch vessel > 2.0 mm in diameter
- Target lesion length >20 mm based on visual estimate by operator
- Target vessel diameter >3.5 mm based on visual estimate by operator
- Target vessel diameter <2.75 mm based on visual estimate by operator
- Pre-treatment of the target lesion (excluding predilation) with another interventional device
Study Plan
This section provides details of the study plan, including how the study is designed and what the study is measuring.
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: I
|
Drug Eluting Stent
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
MACE at 9 months
Time Frame: 9 months
|
9 months
|
Collaborators and Investigators
This is where you will find people and organizations involved with this study.
Sponsor
Collaborators
Investigators
- Principal Investigator: Eberhard Grube, Elizabeth Hospital, Essen Germany
Publications and helpful links
The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.
Study record dates
These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.
Study Major Dates
Study Start
July 1, 2007
Primary Completion (Actual)
November 1, 2008
Study Completion (Actual)
January 1, 2010
Study Registration Dates
First Submitted
September 16, 2008
First Submitted That Met QC Criteria
September 16, 2008
First Posted (Estimate)
September 18, 2008
Study Record Updates
Last Update Posted (Actual)
March 1, 2017
Last Update Submitted That Met QC Criteria
February 28, 2017
Last Verified
February 1, 2017
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- LBCT-H01-07
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
NO
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.