Diagnosis And Treatment of Sleep Apnea in Patient With Heart Failure (DASAP-HF)

February 22, 2017 updated by: Luigi Padeletti

Diagnosis And Treatment of Sleep Apnea in Patient With Heart Failure DASAP-HF Study

DASAP-HF is an observational prospective single arm study. All patients will be treated according to the standard care followed by each center. The protocol requires enrollment of consecutive patients from each center, according to eligibility criteria. All patients must sign the Patient Informed Consent (PIC) before the enrollment in the study. All patients, after the enrollment phase, will be followed for 24 months. Approximately every 12 months a clinical follow-up procedure should be performed in each patient. A sleep study will be done in all patients at 1 month (or at 3 months) from the enrollment, in order to evaluate the performance of the algorithm as a diagnostic tool in this population (primary objective). During the 24 months follow-up period, all Adverse Events occurred in the study population will be collected (HF hospitalizations, all-cause deaths, ventricular arrhythmias, etc.). At the end of the 24 months follow-up, the incidence of clinical events will be evaluated as well as its association with the Respiratory Disturbance Index (RDI) values calculated by APNEA Scan algorithm (secondary objective).

Study Overview

Detailed Description

Heart Failure (HF) is a leading cause of morbidity and mortality in developed countries and a major national and global health problem involving about 2% of the overall population and 10% of the elderly.

A remarkably high proportion (around 50%) of stable optimally treated patients with HF and systolic dysfunction experience persistent, moderate-to-severe breathing disorders both during nighttime e during short-term laboratory recording.Sleep Disordered Breathing (SDB) is associated with transient hypoxia and increased sympathetic activity. Both factors could worsen Left Ventricular Ejection Function (LVEF) or increase serious arrhythmia.

Diagnosing and treating apnea may become a relevant issue in the management of HF patients . Prognostic stratification of congestive HF is an important objective in patient management. Many prognostic stratification scores have been suggested, however none has gained extensive acceptance. Variables used to generate stratification scores must be simple, clinically relevant, and readily obtainable. Furthermore, they must correlate to clinical events, such as hospitalization, Implant Cardioverter Defibrillator (ICD) intervention and mortality. ICD interventions are known to correlate with prognosis, and should thus be included among the end-points.

Cardiac resynchronization therapy (CRT) has been demonstrated to positively affect SA by reducing the apnea-hypopnea index (AHI). The recently developed implantable ventilation sensor which allows automated detection of advanced breathing disorders may provide not only the possibility to closely track the benefit of treatment but also provide further insights into the pathophysiological mechanisms linking Central Sleep Apnea (CSA) to HF. Given that the automated detection of sleep disordered breathing has been only performed in a limited cohort of patients with preserved LVEF requiring pacemaker (PM) implantation for standard bradycardia indications, one aspect requiring clarification is the assessment/validation of the performance of the automated detection in patients with HF.

The RDI is used to assess the severity of sleep apnea based on the total number of complete cessations (apnea) and partial obstructions (hypopnea) of breathing occurring per hour of sleep. These pauses in breathing must last for 10 seconds and are associated with a decrease in oxygenation of the blood. In general, the RDI can be used to classify the severity of disease (mild 5-15, moderate 15-30, and severe greater than 30). An implanted pacing device with a respiratory sensing function may provide clinically useful diagnostics and treatment for sleep-related breathing disorders.

The purpose of this study is to evaluate the performance of the APNEA Scan algorithm in patients implanted with an ICD or CRT-D device endowed with the APNEA Scan algorithm. Primary objective of this study is to evaluate the performance of RDI value calculated by APNEA Scan algorithm, as a binary discriminator of severe Sleep Apnea (SA) as detected by the gold-standard sleep study. Secondary objective of the study is to assess the incidence of clinical events after 24 months of enrollment and investigate its association with the RDI values calculated by APNEA Scan algorithm.

Study Type

Observational

Enrollment (Actual)

265

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Florence, Italy, 50134
        • Department of Heart and Vessels, University of Florence

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Sampling Method

Probability Sample

Study Population

Patients implanted with an ICD or CRT-D endowed with the APNEA Scan algorithm that meet all inclusion/exclusion criteria.will be enrolled after signing of an informed consent form and an authorization to use and disclose health information.

Description

Inclusion Criteria:

  • Patient with left ventricular systolic dysfunction, left ventricular ejection fraction ≤35%, as documented at the moment of device implant, and conventional indication to CRT-D or ICD.
  • Patient implanted with CRT-D or ICD endowed with continuous respiratory sensor designed for sleep apnea monitoring.
  • Age 18 or above, or legal age to provide informed consent according to national law.

Exclusion Criteria:

  • Patient on cardiac resynchronization therapy for a period longer than 7 days.
  • Woman pregnant or planning to become pregnant.
  • Patient is unwilling or unable to sign an authorization to use and disclose health information or an Informed Consent.
  • Patient unavailable to attend scheduled follow-up visits at the center.
  • Patient life expectancy is less than 12 months.
  • Patient is participating in another clinical study that may have an impact on the study endpoints.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Severe Sleep Apnea diagnosed with polysomnography
Time Frame: 27 months
Primary objective of this study is to evaluate the accuracy of RDI value calculated by APNEA Scan algorithm, as a binary discriminator of severe SA as detected by the gold-standard sleep study.
27 months

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Incidence of clinical events
Time Frame: 4 years
Secondary objective of the study is to assess the incidence of clinical events after 24 months of enrollment and investigate its association with the RDI values calculated by APNEA Scan algorithm.
4 years

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

March 1, 2014

Primary Completion (Actual)

September 1, 2016

Study Completion (Anticipated)

July 1, 2018

Study Registration Dates

First Submitted

December 1, 2015

First Submitted That Met QC Criteria

December 1, 2015

First Posted (Estimate)

December 3, 2015

Study Record Updates

Last Update Posted (Actual)

February 23, 2017

Last Update Submitted That Met QC Criteria

February 22, 2017

Last Verified

February 1, 2017

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Heart Failure

Clinical Trials on All market approved CRT-D or ICD systems endowed with the APNEA Scan algorithm