- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT07580456
AI for Gastric POCUS ( Point-of-care Ultrasound) (POCUS)
Development of an Artificial Intelligence Algorithm to Enhance the Gastric Point-of-care Ultrasound. A Proof-of-concept Study.
The goal of this observational study is to train and test an AI (Artificial Intelligence)-based program to assist anesthesiologists in the interpretation of stomach ultrasound images and differentiate a "full" from an "empty" stomach.
It is a healthy-volunteer study, where the participants will undergo ultrasound examination of their stomach at three different time points to visualize the stomach contents. These are at fasting state, after taking some solid food and after taking some water. Here, the participants will be randomized to receive one of five different types solid foods and one of five different volumes of water. The stomach ultrasound images will then be used to train and test the accuracy of the model to diagnose the type of stomach content (nothing vs. clear fluid vs. solid food)
Study Overview
Status
Conditions
Detailed Description
Gastric (stomach) Point-of-care ultrasound (POCUS) is an ultrasound examination done at bedside to assess the stomach. It is a validated non-invasive way to find out what is the content in the stomach and its volume. Gastric POCUS is increasingly used before surgery to determine the risk of gastric contents going into the lungs (possibly causing a lung infection and breathing problems) and guide anesthetic management whenever the doctors are not certain about the stomach content based on clinical information.
Gastric POCUS is a relatively new skill for anesthesiologists. While, obtaining the required images is relatively straightforward, the interpretation of such images, however, requires advanced training. Preliminary data have suggested that Artificial Intelligence (AI)-based programs and devices can help in image capturing and its interpretation for other ultrasound applications. This study will be the first to the researcher's knowledge to develop an AI algorithm to enhance anesthesiologists' ability to recognize a full stomach using gastric POCUS. The goal of this observational study is to train and test an AI (Artificial Intelligence)-based program to assist anesthesiologists in the interpretation of stomach ultrasound images and differentiate a "full" from an "empty" stomach.
This is an observational prospective cohort study that follows the CONSORT (Consolidated Standards of Reporting Trials)-AI extension reporting guidelines.
The researchers expect to enroll 30 healthy volunteers for the study.
Following a period of fasting for solids for at least 8 hours and clear fluids for at least 2 hours from the time of study visit. An anesthesiologist or sonographer with a minimum previous experience of 50 gastric ultrasound examinations will perform a standardized gastric ultrasound exam.
A baseline ultrasound examination will be conducted first with the participant lying on their back with the head elevated at 30 degrees (supine position) and then again with the participant lying on their right side (right lateral decubitus position(RLD)).
The same procedure will be repeated twice after ingestion of
- various volumes of water (100-500) determined at random
- 1 of 5 different solid or thick fluid foods also determined at random (a banana, an apple, a cup of yogurt, a croissant or a muffin).
Each one of the 30 participants will be randomized to 1 of 5 different volumes of water (100ml, 200ml, 300ml, 400ml, 500ml). Then ultrasound images will be obtained. Subsequently, each participant will also be randomized to 1 of 5 solids (a banana, an apple, a cup of yogurt, a croissant or a muffin) in a 1:1:1:1:1 ratio. A computer-generated list of random numbers for each participant will be created.
The investigators plan to collect 90 10-second clips in total, and each clip can be deconstructed into 10 frozen frames per second, for a total of 100 frozen frames per clip. The investigators expect to generate 9,000 individual images, 80% of which will be used to train the model, 10% to fine-tune and 10% to test the model accuracy. The three de-identified clips from each participant will be normalized and annotated by consultant anesthesiologists to indicate orientation (medial or lateral, cephalad or caudad) and identify relevant structures, as well as the type of content and antral CSA in the right lateral decubitus in case of fluid.
All the collected images will then be fed to an AI to generate computational data.
Study Type
Enrollment (Estimated)
Contacts and Locations
Study Contact
- Name: Jayanta Chowdhury, MBBS,MD
- Phone Number: 2016 416-603-5800
- Email: jayanta.chowdhury@uhn.ca
Study Locations
-
-
Ontario
-
Toronto, Ontario, Canada, M5T 2S8
- Toronto Western Hospital, University Health Network
-
Contact:
- Jayanta Chowdhury
- Phone Number: 4166035800
- Email: jayanta.chowdhury@uhn.ca
-
Principal Investigator:
- Anahi Perlas, MD, FRCPC
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
A. Inclusion Criteria at the level of the participants
Participants must meet all the following inclusion criteria to be eligible for the study:
- Aged ≥18 years
- Any sex
- Be healthy
B. Inclusion Criteria at the level of the input data • Transverse ultrasound images (10 sec clips) of the gastric antrum in the epigastric area that contain all these structures:
- The edge of the left lobe of the liver
- The gastric antrum
- The pancreas
- The aorta
Exclusion Criteria:
A. Exclusion Criteria at the level of the participants
Participants meeting any of the following exclusion criteria are ineligible for the study:
- Previous gastro-esophageal surgery (e.g., gastric by-pass, sleeve gastrectomy, fundoplication, partial gastrectomy)
- Allergy to any of the food that will be provided.
B. Exclusion Criteria at the level of the input data
• Ultrasound images (10 sec clips) where the gastric antrum cannot be positively identified.
Study Plan
How is the study designed?
Design Details
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
To see the overall accuracy of the AI model
Time Frame: Through study completion, an average of 2 years
|
To see the overall accuracy of the AI-enhanced ultrasound model to differentiate no content and clear fluid from solid.
|
Through study completion, an average of 2 years
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
To measure the accuracy of the AI model in differentiating a empty from a full stomach
Time Frame: Through study completion, an average of 2 years
|
To see the accuracy of the AI-enhanced ultrasound model to differentiate an "empty" (no content or clear fluid with an antral CSA (Cross-sectional Area)< 10 cm2 in the RLD) from a "full" stomach (solid content or clear fluid with an antral CSA > 10cm2 in the RLD).
|
Through study completion, an average of 2 years
|
|
To measure the balanced accuracy of the AI model
Time Frame: Through study completion, an average of 2 years
|
Balanced accuracy accounts for uneven distributions of detected objects (e.g., small vs. large anatomical structures)
|
Through study completion, an average of 2 years
|
|
To measure the precision of the AI model
Time Frame: Through study completion, an average of 2 years
|
Precision evaluates the proportion of true positives among detected objects, addressing false positives that can lead to unnecessary interventions in clinical settings.
|
Through study completion, an average of 2 years
|
|
To measure the recall of the AI model
Time Frame: Through study completion, an average of 2 years
|
(b) Recall (sensitivity) quantifies the model's ability to detect all relevant objects (true positives), critical for avoiding missed detections (false negatives) in important medical diagnoses.
|
Through study completion, an average of 2 years
|
|
To evaluate the model's classification performance across different confidence thresholds.
Time Frame: Through study completion, an average of 2 years
|
Receiver Operating Characteristic (ROC) curves and Area Under Curve (AUC) will be computed to evaluate the model's classification performance across different confidence thresholds.
|
Through study completion, an average of 2 years
|
|
To evaluate the model's performance in detecting different anatomical structures (e.g., organs, vessels).
Time Frame: Through study completion, an average of 2 years
|
Class-specific mean Average Precision (mAP) will be calculated to evaluate the model's performance in detecting different anatomical structures (e.g., organs, vessels).
mAP is the standard metric for object detection tasks, summarizing precision and recall across multiple confidence thresholds.
|
Through study completion, an average of 2 years
|
|
To measure the latency and average inference time per image
Time Frame: Through study completion, an average of 2 years
|
Given the clinical need for real-time feedback during ultrasound procedures, the average inference time per image and latency will be measured for each model.
|
Through study completion, an average of 2 years
|
Collaborators and Investigators
Investigators
- Principal Investigator: Anahi Perlas, University Health Network, Toronto
Study record dates
Study Major Dates
Study Start (Estimated)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
- 25-6148
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Point-of-care Ultrasound
-
National Taiwan University HospitalNot yet recruiting
-
National Taiwan University HospitalCompletedPoint-of-care UltrasoundTaiwan
-
Asociacion Española Primera en SaludIntensive Care Unit Pasteur HospitalCompletedPoint of Care UltrasoundUruguay
-
Aga Khan UniversityThe Hospital for Sick Children; Grand Challenges CanadaUnknownPoint of Care UltrasoundPakistan
-
Aalborg UniversityThe General Practice Foundation in Denmark (grant number A3495); The Novo Nordisk... and other collaboratorsCompleted
-
Indiana UniversityRecruitingPoint of Care Ultrasound (POCUS)United States
-
Aalborg UniversityCompleted
-
Kantonsspital BadenSpital Limmattal SchlierenNot yet recruitingUltrasound Evaluation | Ultrasound Exam in Emergency/Medical Care | Point of Care Ultrasound (POCUS)Switzerland
-
University of IoanninaRecruiting
-
Hospital for Special Surgery, New YorkCompletedGlucagon-like Peptide 1 | Gastric Ultrasound | Point of Care UltrasoundUnited States, Canada