- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT07634913
Development of a Mobile Terminal-Based Intelligent Detection System for Multiple Anterior Segment Diseases of the Eye (LENS)
This is a multi-center, cross-sectional study evaluating a smartphone-based artificial intelligence (AI) system for anterior segment eye disease screening. The system is designed to identify 16 clinically important anterior segment conditions from images captured using a standard Android smartphone. A core design feature of the system is that all image analysis is performed entirely on the smartphone itself, without requiring internet connectivity or cloud-based server infrastructure.
The study is motivated by a structural challenge in the deployment of medical AI: systems that depend on cloud infrastructure for inference are non-functional in settings without reliable internet access, which disproportionately excludes populations in low-resource regions where the burden of preventable eye disease is highest. This study evaluates whether an on-device AI system, designed with operational constraints as a primary engineering objective, can deliver clinically acceptable diagnostic performance while remaining operable under real-world connectivity limitations.
The study comprises five evaluation components. First, the diagnostic performance of the AI system is benchmarked against board-certified ophthalmologists of varying seniority on a standardized set of smartphone-captured anterior segment images. Second, the usability of the system is evaluated among non-medical users who perform self-administered screening with minimal instruction, with per-screening time recorded across consecutive attempts to characterize the learning curve. Third, a head-to-head field trial directly compares the on-device AI system against a functionally equivalent cloud-based deployment of the same model architecture across key operational dimensions including screening duration, diagnostic performance, and user acceptability. Fourth, population-level screening is conducted among consecutively enrolled community residents at two low-resource sites, with per-disease sensitivity and specificity calculated against reference-standard slit-lamp examinations. Fifth, pre-specified health-economic and environmental analyses compare the two deployment modalities in terms of per-person screening cost, cost-effectiveness, per-inference electricity consumption, and projected carbon emissions at scale.
The reference standard for all diagnostic comparisons is slit-lamp biomicroscopic examination performed by board-certified ophthalmologists. The study is designed and reported in accordance with the DECIDE-AI reporting guideline for early-stage clinical evaluation of AI-driven decision-support systems.
Study Overview
Status
Conditions
Study Type
Enrollment (Estimated)
Contacts and Locations
Study Contact
- Name: Haotian Lin
- Phone Number: +86 13802793086
- Email: haot.lin@hotmail.com
Study Contact Backup
- Name: Longhui Li
Study Locations
-
-
Guangdong
-
Guangzhou, Guangdong, China, 510060
- Recruiting
- Zhongshan Ophthalmic Center, Sun Yat-sen University
-
Contact:
- Haotian Lin
- Phone Number: +86 13802793086
- Email: haot.lin@hotmail.com
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Adults aged 18 years or older;
- Willing to participate and able to provide written informed consent prior to enrollment.
Exclusion Criteria:
- Unable to cooperate with anterior segment image capture (including smartphone-based photography or slit-lamp biomicroscopy).
Study Plan
How is the study designed?
Design Details
Cohorts and Interventions
Group / Cohort |
Intervention / Treatment |
|---|---|
|
On-Device Deployment Group
Participants screened using a smartphone-based AI system that performs all image inference locally on the device without requiring internet connectivity.
The AI system analyzes smartphone-captured anterior segment images and generates diagnostic outputs entirely on the smartphone hardware, independent of cloud infrastructure or network access.
|
A structured-pruned one-stage object-detection model deployed as a standalone Android application, performing all image inference on-device without internet connectivity, designed to detect 16 anterior segment eye diseases from smartphone-captured images.
|
|
Cloud-Based Deployment Group
Participants screened using a functionally equivalent deployment of the same AI model architecture, in which smartphone-captured anterior segment images are transmitted to a remote server for inference, with diagnostic outputs returned via internet connection.
This group serves as the comparator to evaluate the operational differences attributable solely to deployment modality, as the underlying model architecture is identical between the two groups.
|
A structured-pruned one-stage object-detection model deployed as a standalone Android application, performing all image inference on-device without internet connectivity, designed to detect 16 anterior segment eye diseases from smartphone-captured images.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Case-level diagnostic accuracy of the AI system compared with board-certified ophthalmologists
Time Frame: Day 1
|
Case-level accuracy is defined as the proportion of images with fully correct diagnostic labels concordant with the reference standard.
The AI system and board-certified ophthalmologists stratified by clinical seniority (junior: fewer than 5 years of independent practice; intermediate: 5 to 15 years; senior: more than 15 years) independently evaluate the same standardized set of smartphone-captured anterior segment images, sampled to ensure balanced representation of all 16 disease categories and normal eyes.
The reference standard for each image is established by a senior ophthalmologist with more than 30 years of clinical experience who does not participate in the benchmarking exercise.
Clinicians are masked to the AI system output and to each other's assessments throughout.
|
Day 1
|
|
Diagnostic accuracy of the AI system when operated by non-medical users
Time Frame: Day 1
|
Diagnostic accuracy is defined as the proportion of images correctly classified by non-medical users operating the AI system independently.
Non-medical users, including patients and their family members attending the outpatient clinic of Zhongshan Ophthalmic Center, are instructed to install the AI application on their own smartphones, follow the in-app guidelines, and capture anterior segment images of an accompanying person to receive a screening result.
All inference is performed on-device without internet connectivity.
AI-generated diagnostic outputs are compared with reference-standard diagnoses obtained from subsequent slit-lamp examinations performed by ophthalmologists at the same clinic.
|
Day 1
|
|
Sensitivity of the on-device AI system in population-level community screening
Time Frame: Day 1
|
Sensitivity is defined as the proportion of participants with a given anterior segment disease who are correctly identified as positive by the on-device AI system (true positives divided by the sum of true positives and false negatives), calculated separately for each target disease category.
Village staff without medical training use the on-device AI system to screen consecutively enrolled local residents.
The reference standard is established through slit-lamp examinations performed by ophthalmologists.
|
Day 1
|
|
Incremental cost-effectiveness ratio of on-device versus cloud-based screening
Time Frame: Day 1
|
The incremental cost-effectiveness ratio (ICER) is defined as the difference in lifetime costs between on-device and cloud-based screening divided by the difference in quality-adjusted life-years (QALYs) between the two strategies, estimated from a pre-specified decision-analytic model comprising a decision tree with a downstream Markov state-transition structure applied to a simulated cohort of 100,000 individuals.
|
Day 1
|
|
Per-inference electricity consumption of on-device versus cloud-based deployment
Time Frame: Day 1
|
Electricity consumption in joules per inference cycle is measured over 10,000 inference cycles on both the on-device smartphone and a standardized cloud-server configuration (Intel Xeon Gold 6248 CPU, NVIDIA Tesla V100 GPU) using the Experiment Impact Tracker toolkit.
Cloud-server measurements are averaged across low-traffic and high-traffic server conditions.
Results are reported separately for the on-device and cloud-based deployment modalities and compared as a ratio.
|
Day 1
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Total image evaluation time of the AI system compared with board-certified ophthalmologists
Time Frame: Day 1
|
Total time in seconds required to complete independent evaluation of all images in the standardized benchmarking set, recorded separately for the AI system and for the board-certified ophthalmologists.
Reported as mean with standard deviation for both the AI system and the clinician group.
|
Day 1
|
|
Per-screening time learning curve among non-medical operators
Time Frame: Day 1
|
The duration of each screening attempt in seconds is recorded for analysis.
Participants repeat the screening process and self-evaluate their operating proficiency after each attempt.
The procedure is concluded once a participant deems himself or herself proficient for three consecutive attempts.
The learning curve is characterized by the change in mean per-screening duration across consecutive attempts.
|
Day 1
|
|
Screening duration comparing on-device and cloud-based deployment in resource-limited field settings
Time Frame: Day 1
|
Mean screening duration in seconds per participant, recorded for each of the two deployment modalities: on-device inference and cloud-based inference using a functionally equivalent deployment of the identical model architecture with inference performed on a remote server.
Local residents are divided into two equal groups and screened by village staff without medical training using either the on-device or the cloud-based system.
|
Day 1
|
|
User acceptability comparing on-device and cloud-based deployment in resource-limited field settings
Time Frame: Day 1
|
User acceptability is assessed using a questionnaire investigating patient satisfaction, privacy concerns, and willingness to recommend the AI system, administered to participants in both the on-device and cloud-based deployment groups.
Local residents are divided into two equal groups and screened by village staff without medical training using either the on-device or the cloud-based system.
Questionnaire responses are compared between the two deployment groups.
|
Day 1
|
|
Diagnostic accuracy of the on-device AI system in population-level community screening
Time Frame: Day 1
|
Diagnostic accuracy is defined as the proportion of participants for whom the AI system assigns a correct diagnostic label concordant with the reference standard.
Village staff without medical training use the on-device AI system to screen consecutively enrolled local residents.
The reference standard is established through slit-lamp examinations performed by ophthalmologists.
|
Day 1
|
|
Specificity of the on-device AI system in population-level community screening
Time Frame: Day 1
|
Specificity is defined as the proportion of participants without a given anterior segment disease who are correctly identified as negative by the on-device AI system (true negatives divided by the sum of true negatives and false positives), calculated separately for each target disease category.
Village staff without medical training use the on-device AI system to screen consecutively enrolled local residents.
The reference standard is established through slit-lamp examinations performed by ophthalmologists.
|
Day 1
|
Collaborators and Investigators
Investigators
- Principal Investigator: Longhui Li, Zhongshan Ophthalmic Center, Sun Yat-sen University
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
- Pathologic Processes
- Infections
- Hemorrhage
- Eye Diseases
- Bacterial Infections
- Bacterial Infections and Mycoses
- Orbital Diseases
- Lens Diseases
- Conjunctival Diseases
- Eyelid Diseases
- Eye Infections, Bacterial
- Eye Infections
- Eye Hemorrhage
- Pathological Conditions, Signs and Symptoms
- Cataract
- Conjunctivitis
- Entropion
- Blepharitis
- Pterygium
- Ectropion
- Exophthalmos
- Hordeolum
- Hyphema
Other Study ID Numbers
- 2023KYPJ274
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Exophthalmos
-
Laura ICONARUActive, not recruiting
-
argenxNot yet recruiting
-
Merida BiosciencesRecruitingGraves DiseaseUnited States
-
argenxNot yet recruitingGraves Disease | Graves' Disease
-
Shanghai Zhongshan HospitalRecruiting
-
Shanghai Zhongshan HospitalRecruiting
-
Northwell HealthRecruitingGraves Disease | Hyperthyroidism | Graves' DiseaseUnited States
-
Immunovant Sciences GmbHEnrolling by invitationGraves' DiseaseUnited States, Australia
-
Sun Yat-sen UniversityUnknownHypothyroidism | ExophthalmosChina
-
IRCCS Ospedale San RaffaeleIRCCS Azienda Ospedaliero-Universitaria di Bologna; Federico II University; Azienda... and other collaboratorsEnrolling by invitationChildren | Autoimmune HyperthyroidismItaly
Clinical Trials on Smartphone-based on-device artificial intelligence system for anterior segment eye disease screening
-
The Children's Hospital of Zhejiang University...Not yet recruiting
-
State Scientific Centre of Coloproctology, Russian...Not yet recruitingColonic Polyp | Colonic Neoplasms | DiagnosisRussian Federation