Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Initial Assessment of 18FDG-PET/MRIin Determining the Extent of Systemic Disease in Breast Cancer Patients

12. října 2021 aktualizováno: NYU Langone Health

Initial Assessment of 18FDG-PET/MRI in Determining the Extent of Systemic Disease in Breast Cancer Patients.

Because MRI can provide increased brain and liver lesion detection as compared with CT, the investigators hypothesize that FDG-PET/MRI will provide concordant or improved lesion detection as compared with FDG-PET/CT in breast cancer patients at a decreased radiation dose.

Přehled studie

Postavení

Dokončeno

Podmínky

Intervence / Léčba

Detailní popis

This study is an initial assessment of the ability of 18FDG-PET/MR imaging to detect systemic disease in breast cancer patients as compared with conventional 18FDG-PET/CT.

Rationale: Accurate assessment of the extent systemic disease in breast cancer patients both initially and throughout treatment and surveillance comprises the basis for clinical care including surgical planning, radiation and drug selection. Shortcomings in FDG-PET/CT, a common current method of disease detection and surveillance, include decreased sensitivity in brain, liver and bone and a relatively high radiation dose, which could cause up to 5 new cancers per 1,000 patients (young American women) per scan. Initial studies assessing whole body MRI, a technique which involves no radiation, in the staging of breast cancer patients show promise, but can suffer from decreased ability to detect nodal disease and from detection of false positive lesions. Manual fusion of PET and MRI data in bowel and breast organ systems has been shown to decrease false positive lesions as compared with MRI alone. In the past year, molecular MRI imaging machines which combine PET and MRI imaging have become available for research purposes.

Hypothesis 1: We therefore hypothesize that FDG-PET/MRI will provide concordant or improved lesion detection as compared with FDG-PET/CT in breast cancer patients at a decreased radiation dose.

Hypothesis 2: In addition, the simultaneously acquired PET and MRI data allows for analysis of local tumor characteristics including perfusion, cellularity and glucose metabolism. In the subgroup of patients with an index breast cancer, we hypothesize that these local tumor metrics correlate with number and sites of systemic lesions.

Methods: All newly diagnosed breast cancer patients who are undergoing imaging evaluation for initial extent of disease or disease surveillance at NYU Cancer Center and Bellevue hospital are candidates for study in this protocol. Patients will be invited for follow-up FDG-PET/MRI imaging at any time they are undergoing FDG-PET/CT as part of their clinical care.

Subjects are undergoing FDG-PET/CT at the Cancer Center on 34th St and Lexington Avenue as part of routine care and will be transferred directly to the 38th St. facility by car in a timely manner so that an additional dose of 18-FDG labeled glucose will be unnecessary for the experimental FDG-PET/MRI.

FDG-PET/MRI will be performed and is estimated to 45-60 minutes of scanning time. The patient will then be free to leave the department. Data will be transferred to a workstation and interpreted by two independent radiologists. Size and location of each lesion will be recorded in a confidentiality protected spreadsheet for each component of the scan and the lesion load will be defined by the union of all detected lesions from all three components (DCE-MRI, diffusion-weighted imaging (DWI), FDG-PET). Data will be compared on a per lesion, per organ system and per patient basis with the patient's routine FDG-PET/CT for presence of metastatic disease and size and number of metastatic lesions.

In the case where PET/MRI demonstrates metastatic disease not seen on routine modalities, the referring physician will be alerted. Additional dedicated radiologic studies and biopsy may be recommended and performed at the discretion of the referring physician.

Results: Results of FDG-PET/MRI and FDG-PET/CT findings will be reported in a descriptive format together with related biopsy results and histopathologic correlation. An exact 95% confidence interval will be derived for the true percentage of times the assessment of disease state lesion, per organ system and per patient from FDG-PET/MRI will be concordant with the assessments derived for the same patient using the FDG-PET/CT. In patients with an index breast cancer, Pearson and Spearman rank correlations will be used to characterize the association between local tumor metrics and metastatic burden and location.

Potential benefits: 1. Equal or improved ability to detect metastatic disease in breast cancer patients at a decreased radiation dose. 2. An improved understanding of index tumor metrics help stratify risk for metastatic disease based on the index tumor and enable individually tailored surveillance.

Typ studie

Intervenční

Zápis (Aktuální)

80

Fáze

  • Nelze použít

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

    • New York
      • New York, New York, Spojené státy, 10016
        • NYU School of Medicine

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

20 let až 80 let (Dospělý, Starší dospělý)

Přijímá zdravé dobrovolníky

Ne

Pohlaví způsobilá ke studiu

Všechno

Popis

Inclusion Criteria:

Any patient with a history or breast cancer undergoing PET/CT either for initial staging or for disease surveillance

-

Exclusion Criteria:

  • Pregnant patients and patients with known contraindications for whole body MR imaging (e.g., pacemakers, recent surgery, brain vascular clips, etc.) will be excluded from the study. Patients will be screened with a questionnaire to be sure they have no medical devices that could make the procedure unsafe. Patients with glomerular filtration rate (GFR) < 15 ml/min/1.73m2 or who are on dialysis will be excluded from the study.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Diagnostický
  • Přidělení: N/A
  • Intervenční model: Přiřazení jedné skupiny
  • Maskování: Žádné (otevřený štítek)

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Jiný: PET/MRI
PET/MRI

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Časové okno
Number of metastatic lesions seen on PET/MRI as compared with PET/CT
Časové okno: 1 year
1 year

Sekundární výstupní opatření

Měření výsledku
Časové okno
Patient stage as imaged by PET/MRI as compared with PET/CT
Časové okno: 1 year
1 year

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Vyšetřovatelé

  • Vrchní vyšetřovatel: Laura Heacock, MD, NYU School of Medicine

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

1. července 2012

Primární dokončení (Aktuální)

5. října 2021

Dokončení studie (Aktuální)

5. října 2021

Termíny zápisu do studia

První předloženo

21. srpna 2012

První předloženo, které splnilo kritéria kontroly kvality

23. srpna 2012

První zveřejněno (Odhad)

24. srpna 2012

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

14. října 2021

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

12. října 2021

Naposledy ověřeno

1. října 2021

Více informací

Termíny související s touto studií

Klíčová slova

Další identifikační čísla studie

  • 12-02243

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Předplatit