The goal of this clinical trial is to demonstrate control of digital devices through a brain implant in people with spinal cord injury. The main question it aims to answer is efficient, independent, BCI-based control over digital devices in settings of daily living of an individual with SCI. In this project an advanced generation fully implantable BCI system will be used, the Brain InterChange (BIC) from CorTec.
Participants will be implanted with an electrode grid on the surface of the brain and an amplifier/transmitter on the skull, under the skin. Participation includes visits of researchers for recording and training at home, 1-3 times per week for one year. Extension of participation after one year is possible. If successful, the participant will be able to use the BCI at home independently, without the presence of a researcher.
Přehled studie
Postavení
Podmínky
Intervence / Léčba
Detailní popis
Spinal Cord Injury (SCI) results in motor impairments in body parts innervated by the spinal cord below the site of the lesion. In addition to loss of leg movements, individuals with high cervical SCI experience significant impairments in arm and hand function (tetraplegia), impacting their access to digital devices, with obvious consequences for their ability to communicate, participate in society and the workforce, autonomously manage their life, and benefit from the entertainment options digital devices offer these days. Current assistive technologies (AT) for control over digital devices, such as voice control, eye-tracking, and head- or mouth-controlled devices, are often unintuitive, slow, limited in functionality, aesthetically unattractive, and they often interfere with regular movement or speech. An effective Brain-Computer Interface (BCI) would enable individuals with SCI to use movement-related neural signals to directly control digital devices, taking away the disadvantages of current AT. This would dramatically improve their quality of life.
The Brain InterChange from CorTec is an active implantable medical device for measurement of neuronal activity and electrical stimulation of the human nervous system, comprising an internal and an external unit. The internal unit consists of a small high-density ECoG grid with 32 contacts placed subdurally and a connected implantable amplifier/transmitter device that is placed subcutaneously. The external unit comprises a headpiece, for power transmission to the internal unit, a communication unit, that receives the data transmitted from the internal unit and controls the power transmission, and a USB cable, that connects the communication unit to the computer that has software to process and translate the brain data to a means of digital device control for SCI patients with custom in-house software developed during this study.
The BCI system also allows to provide users with somatosensory feedback about their motor attempts (in addition to the visual feedback), by delivering electrocortical stimulation (ECS) to the somatosensory regions of the brain. As such, the aim is to generate a more natural relation between intent (movement attempt of a body part) and effect (sensation in the same body part), which is expected to lead to fast training and accurate BCI performance.
Typ studie
Zápis (Odhadovaný)
Fáze
- Nelze použít
Kontakty a umístění
Studijní kontakt
- Jméno: Mariska J Vansteensel, PhD
- Telefonní číslo: +31887555121
- E-mail: neuroprothese@umcutrecht.nl
Studijní záloha kontaktů
- Jméno: Erik J Aarnoutse, PhD
- Telefonní číslo: +31887555123
- E-mail: e.j.aarnoutse@umcutrecht.nl
Studijní místa
-
-
Utrecht
-
Utrecht, Utrecht, Holandsko, 3584CX
- Nábor
- University Medical Center Utrecht
-
Kontakt:
- Mariska J Vansteensel, PhD
- Telefonní číslo: +31887555121
- E-mail: neuroprothese@umcutrecht.nl
-
Kontakt:
- Erik J Aarnoutse, PhD
- Telefonní číslo: +31887555123
- E-mail: e.j.aarnoutse@umcutrecht.nl
-
Vrchní vyšetřovatel:
- Nick F Ramsey, PhD
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dospělý
- Starší dospělý
Přijímá zdravé dobrovolníky
Popis
Inclusion Criteria:
- Clinical diagnosis of SCI at the cervical level C4 or higher (C1-C4)
- Complete or incomplete tetraplegia (quadriplegia) or tetraparesis (quadriparesis), i.e., level A or B at the American Spinal Injury Association (ASIA) Impairment Scale
- Meeting surgical safety criteria, including surgical clearance by the study physicians
- Meeting (neuro)psychological evaluation criteria
- Ability to communicate reliably, via speech or other means
- Willingness and ability to provide informed consent.
- Lives within reasonable distance from UMC Utrecht
- Participant consents to the study and still wishes to participate at the time of the study.
- Vision and hearing largely intact.
- For candidates who are not currently receiving invasive ventilation, and who have current respiratory problems (e.g., at night), there should be a clear and confirmed desire to proceed with tracheostomy ventilation whenever that would become necessary.
Exclusion Criteria:
- Having a spinal cord injury with a degenerative or progressive etiology.
- Having evident swallowing problems.
- Having a significant current or recent anxiety disorder or depression or cognitive impairment that would interfere with obtaining informed consent or fully participating in study activities.
- Medical conditions contraindicating surgery of a chronically implanted device or that could interfere with study participation (for example active infections, unexplained fever, existing scalp lesions or skin breakdown, osteomyelitis, hepatitis, any autoimmune disease/disorder, epilepsy, skin disorders causing excessive skin sloughing or poor wound healing, cranioplasty, significant cardiovascular, metabolic, or renal impairments, chronic oral or intravenous use of steroids or immunosuppressive therapy, active cancer within the past year or requires chemotherapy, uncontrolled autonomic dysreflexia within the past 3 months, hydrocephalus with or without an implanted ventricular shunt or a medical contraindication to stop anti-coagulant medications during surgery, or a catabolic state, or strong and frequent spasms)
- Presence of pre-surgical findings in anatomical, functional, and/or vascular neuroimaging that makes achieving implant locations too challenging or incompatible with desired risk levels.
- Inability to undergo MRI for pre-implantation evaluation, for example due to the presence of implanted devices that are incompatible with MRI, which may include pacemakers, cardiac defibrillators, spinal cord or vagal nerve stimulators, deep brain stimulators, and cochlear implants or devices that deliver diaphragm pacing.
- Anticipated need for MRI after implantation of the Brain InterChange system.
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Podpůrná péče
- Přidělení: N/A
- Intervenční model: Přiřazení jedné skupiny
- Maskování: Žádné (otevřený štítek)
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Experimentální: ECoG (electrocorticography) sensing
Use implantable ECoG-based Brain Computer interface to control digital devices
|
Implant electrodes and amplifier/transmitter and use, through amplifier and decoding, for control of BCI
Ostatní jména:
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Effectiveness of BCI Control: Accuracy
Časové okno: 1 year
|
Accuracy: >80% sensitivity (true positive rate) for 1-command control; 80% classification accuracy (distinguishing between multiple classes) for multi-command control; and 80% classification accuracy and the correlation between the intended and actual response for multi-command continuous control
|
1 year
|
|
Efficiency of BCI control: Speed
Časové okno: 1 year
|
number of accurate selections made per minute
|
1 year
|
|
Efficiency of BCI control: Subjective Workload - Visual Analogue Scale
Časové okno: 1 year
|
Subjective Workload: Visual Analogue Scale Continuous scale: Little to no effort (0) - Much effort (5).
Lower numbers are better.
|
1 year
|
|
Efficiency of BCI control: Subjective Workload - National Aeronautics and Space Administration-Task Load Index
Časové okno: 1 year
|
Subjective Workload: National Aeronautics and Space Administration-Task Load Index Scale: 21 point Likert-type scale.
Lower numbers are better.
|
1 year
|
|
User satisfaction Quebec User Evaluation of Satisfaction with assistive Technology (QUEST)
Časové okno: 1 year
|
User Satisfaction: Quebec User Evaluation of Satisfaction with assistive Technology version 2.0. Likert-type scale: Extremely dissatisfied - Dissatisfied - Slightly satisfied - Satisfied - Extremely satisfied. Extremely Satisfied is the best result. |
1 year
|
|
user satisfaction Psychosocial impact of assistive devices scale (PIADS)
Časové okno: 1 year
|
User Satisfaction: Psychosocial impact of assistive devices scale.
Likert-type scale -3, -2, -1, 0, 1, 2, 3. 3 is best result.
|
1 year
|
|
Stability of BCI performance: impedance
Časové okno: 1 year
|
Longitudinally follow the electrode impedance (in Ω), to assess their stability throughout the day and across the weeks and months after implantation.
|
1 year
|
|
Stability of BCI performance: signal dynamics
Časové okno: 1 year
|
Longitudinally follow the raw signal dynamics (in µV) of neural signals, to assess their stability throughout the day and across the weeks and months after implantation.
|
1 year
|
|
Stability of BCI performance: task-related modulation
Časové okno: 1 year
|
Longitudinally follow the task-related modulation in power (in µV), to assess their stability throughout the day and across the weeks and months after implantation.
|
1 year
|
|
Effects of somatosensory feedback on BCI Training and Performance: accuracy
Časové okno: 1 year
|
Compare BCI control accuracy (in %), including variability and improvement therein before and after applying somatosensory feedback through electrocortical stimulation of the somatosensory cortex
|
1 year
|
|
Effects of somatosensory feedback on BCI Training and Performance: neural signals
Časové okno: 1 year
|
Compare neural signal changes (in µV) in the sensorimotor areas before and after applying somatosensory feedback through electrocortical stimulation of the somatosensory cortex
|
1 year
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Assess device specifications for future, larger-scale, application of HD ECoG-BCIs
Časové okno: 1 year
|
qualitative description on device specifications and experimental parameters, such as the specific decoder settings, for future, larger scale, application of HD ECoG-BCIs
|
1 year
|
|
Validation of software for independent home-use of advanced BCIs
Časové okno: 1 year
|
Validation: Questionnaire to evaluate user satisfaction and ease of use of the home use software. Likert-type scale: fully disagree - disagree - neither agree or disagree - agree - fully agree - not applicable. Fully agree is the best result. |
1 year
|
Spolupracovníci a vyšetřovatelé
Sponzor
Vyšetřovatelé
- Vrchní vyšetřovatel: Nick F Ramsey, PhD, UMC Utrecht
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Odhadovaný)
Primární dokončení (Odhadovaný)
Dokončení studie (Odhadovaný)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Další relevantní podmínky MeSH
- Neurologické projevy
- Onemocnění centrálního nervového systému
- Nemoci nervového systému
- Rány a zranění
- Trauma, nervový systém
- Nemoci míchy
- Ochrnutí
- Patologické stavy, příznaky a symptomy
- Příznaky a symptomy
- Poranění míchy
- Kvadruplegie
- Diagnostické techniky a postupy
- Diagnóza
- Diagnostické techniky, neurologické
- Elektrodiagnostika
- Elektrokortikografie
Další identifikační čísla studie
- NL-009756
- METC nummer 25-211 (Jiný identifikátor: NedMec)
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Popis plánu IPD
Časový rámec sdílení IPD
Kritéria přístupu pro sdílení IPD
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .
Klinické studie na Poranění míchy
-
Assiut UniversityDokončeno
-
University of Sao PauloZatím nenabírámeOtok | Varixy; CordBrazílie
-
Qianfoshan HospitalChinese Medical AssociationNábor
-
Tel-Aviv Sourasky Medical CenterNeznámýOprava kraniosynostózy | Untethering of Cord
-
National University of MalaysiaMalaysia Automotive Robotics and Innovation of Technology InstituteDokončenoProtilátka | Vakcína | Mateřský | CordMalajsie
-
M.D. Anderson Cancer CenterNational Cancer Institute (NCI)NáborTransplantace hematopoetických kmenových buněk | Transplantace kmenových buněk z pupečníkové krve | Transplantace pupečníkové krveSpojené státy
-
University of Southern CaliforniaDokončenoDysfonie | Atrofie hlasivek | Presbylarynx | Atrofie; Hrtan | Presbylarynges | Jizva vokálních záhybů | Sulcus Vocalis z Vocal CordSpojené státy
Klinické studie na ECoG (electrocorticography) sensing
-
University Hospital, GrenobleNáborTraumatická tetraplegie s poraněním krční šňůryFrancie
-
Second Affiliated Hospital, School of Medicine,...NáborMrtvice | ALS | Afázie | Dysartrie | Mozkový nádor pro dospělé | Poruchy řeči a jazyka | lock-in syndrom | EpilepsieČína
-
Acutus MedicalZatím nenabírámeParoxysmální fibrilace síní | Přetrvávající fibrilace síní
-
Acutus MedicalStaženoParoxysmální fibrilace síní | Přetrvávající fibrilace síní
-
University College, LondonNáborIschemie mozku | Poranění mozku | NeurochirurgieSpojené království
-
Stanford UniversityAktivní, ne náborAnestézieSpojené státy
-
University of New MexicoStaženoChronický subdurální hematom
-
University Hospital, GrenobleNeznámýNádorová nebo epileptická kortektomieFrancie
-
Nader PouratianMedtronicStaženo