- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT07640711
Innovative Brain-Computer Interface for People With Spinal Cord Injury (INTENSE-BCI)
Innovative Neurotechnology For Society - Brain-Computer Interface
The goal of this clinical trial is to demonstrate control of digital devices through a brain implant in people with spinal cord injury. The main question it aims to answer is efficient, independent, BCI-based control over digital devices in settings of daily living of an individual with SCI. In this project an advanced generation fully implantable BCI system will be used, the Brain InterChange (BIC) from CorTec.
Participants will be implanted with an electrode grid on the surface of the brain and an amplifier/transmitter on the skull, under the skin. Participation includes visits of researchers for recording and training at home, 1-3 times per week for one year. Extension of participation after one year is possible. If successful, the participant will be able to use the BCI at home independently, without the presence of a researcher.
Tutkimuksen yleiskatsaus
Tila
Interventio / Hoito
Yksityiskohtainen kuvaus
Spinal Cord Injury (SCI) results in motor impairments in body parts innervated by the spinal cord below the site of the lesion. In addition to loss of leg movements, individuals with high cervical SCI experience significant impairments in arm and hand function (tetraplegia), impacting their access to digital devices, with obvious consequences for their ability to communicate, participate in society and the workforce, autonomously manage their life, and benefit from the entertainment options digital devices offer these days. Current assistive technologies (AT) for control over digital devices, such as voice control, eye-tracking, and head- or mouth-controlled devices, are often unintuitive, slow, limited in functionality, aesthetically unattractive, and they often interfere with regular movement or speech. An effective Brain-Computer Interface (BCI) would enable individuals with SCI to use movement-related neural signals to directly control digital devices, taking away the disadvantages of current AT. This would dramatically improve their quality of life.
The Brain InterChange from CorTec is an active implantable medical device for measurement of neuronal activity and electrical stimulation of the human nervous system, comprising an internal and an external unit. The internal unit consists of a small high-density ECoG grid with 32 contacts placed subdurally and a connected implantable amplifier/transmitter device that is placed subcutaneously. The external unit comprises a headpiece, for power transmission to the internal unit, a communication unit, that receives the data transmitted from the internal unit and controls the power transmission, and a USB cable, that connects the communication unit to the computer that has software to process and translate the brain data to a means of digital device control for SCI patients with custom in-house software developed during this study.
The BCI system also allows to provide users with somatosensory feedback about their motor attempts (in addition to the visual feedback), by delivering electrocortical stimulation (ECS) to the somatosensory regions of the brain. As such, the aim is to generate a more natural relation between intent (movement attempt of a body part) and effect (sensation in the same body part), which is expected to lead to fast training and accurate BCI performance.
Opintotyyppi
Ilmoittautuminen (Arvioitu)
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskeluyhteys
- Nimi: Mariska J Vansteensel, PhD
- Puhelinnumero: +31887555121
- Sähköposti: neuroprothese@umcutrecht.nl
Tutki yhteystietojen varmuuskopiointi
- Nimi: Erik J Aarnoutse, PhD
- Puhelinnumero: +31887555123
- Sähköposti: e.j.aarnoutse@umcutrecht.nl
Opiskelupaikat
-
-
Utrecht
-
Utrecht, Utrecht, Alankomaat, 3584CX
- Rekrytointi
- University Medical Center Utrecht
-
Ottaa yhteyttä:
- Mariska J Vansteensel, PhD
- Puhelinnumero: +31887555121
- Sähköposti: neuroprothese@umcutrecht.nl
-
Ottaa yhteyttä:
- Erik J Aarnoutse, PhD
- Puhelinnumero: +31887555123
- Sähköposti: e.j.aarnoutse@umcutrecht.nl
-
Päätutkija:
- Nick F Ramsey, PhD
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
- Aikuinen
- Vanhempi Aikuinen
Hyväksyy terveitä vapaaehtoisia
Kuvaus
Inclusion Criteria:
- Clinical diagnosis of SCI at the cervical level C4 or higher (C1-C4)
- Complete or incomplete tetraplegia (quadriplegia) or tetraparesis (quadriparesis), i.e., level A or B at the American Spinal Injury Association (ASIA) Impairment Scale
- Meeting surgical safety criteria, including surgical clearance by the study physicians
- Meeting (neuro)psychological evaluation criteria
- Ability to communicate reliably, via speech or other means
- Willingness and ability to provide informed consent.
- Lives within reasonable distance from UMC Utrecht
- Participant consents to the study and still wishes to participate at the time of the study.
- Vision and hearing largely intact.
- For candidates who are not currently receiving invasive ventilation, and who have current respiratory problems (e.g., at night), there should be a clear and confirmed desire to proceed with tracheostomy ventilation whenever that would become necessary.
Exclusion Criteria:
- Having a spinal cord injury with a degenerative or progressive etiology.
- Having evident swallowing problems.
- Having a significant current or recent anxiety disorder or depression or cognitive impairment that would interfere with obtaining informed consent or fully participating in study activities.
- Medical conditions contraindicating surgery of a chronically implanted device or that could interfere with study participation (for example active infections, unexplained fever, existing scalp lesions or skin breakdown, osteomyelitis, hepatitis, any autoimmune disease/disorder, epilepsy, skin disorders causing excessive skin sloughing or poor wound healing, cranioplasty, significant cardiovascular, metabolic, or renal impairments, chronic oral or intravenous use of steroids or immunosuppressive therapy, active cancer within the past year or requires chemotherapy, uncontrolled autonomic dysreflexia within the past 3 months, hydrocephalus with or without an implanted ventricular shunt or a medical contraindication to stop anti-coagulant medications during surgery, or a catabolic state, or strong and frequent spasms)
- Presence of pre-surgical findings in anatomical, functional, and/or vascular neuroimaging that makes achieving implant locations too challenging or incompatible with desired risk levels.
- Inability to undergo MRI for pre-implantation evaluation, for example due to the presence of implanted devices that are incompatible with MRI, which may include pacemakers, cardiac defibrillators, spinal cord or vagal nerve stimulators, deep brain stimulators, and cochlear implants or devices that deliver diaphragm pacing.
- Anticipated need for MRI after implantation of the Brain InterChange system.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Tukevaa hoitoa
- Jako: Ei käytössä
- Inventiomalli: Yksittäinen ryhmätehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Kokeellinen: ECoG (electrocorticography) sensing
Use implantable ECoG-based Brain Computer interface to control digital devices
|
Implant electrodes and amplifier/transmitter and use, through amplifier and decoding, for control of BCI
Muut nimet:
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Effectiveness of BCI Control: Accuracy
Aikaikkuna: 1 year
|
Accuracy: >80% sensitivity (true positive rate) for 1-command control; 80% classification accuracy (distinguishing between multiple classes) for multi-command control; and 80% classification accuracy and the correlation between the intended and actual response for multi-command continuous control
|
1 year
|
|
Efficiency of BCI control: Speed
Aikaikkuna: 1 year
|
number of accurate selections made per minute
|
1 year
|
|
Efficiency of BCI control: Subjective Workload - Visual Analogue Scale
Aikaikkuna: 1 year
|
Subjective Workload: Visual Analogue Scale Continuous scale: Little to no effort (0) - Much effort (5).
Lower numbers are better.
|
1 year
|
|
Efficiency of BCI control: Subjective Workload - National Aeronautics and Space Administration-Task Load Index
Aikaikkuna: 1 year
|
Subjective Workload: National Aeronautics and Space Administration-Task Load Index Scale: 21 point Likert-type scale.
Lower numbers are better.
|
1 year
|
|
User satisfaction Quebec User Evaluation of Satisfaction with assistive Technology (QUEST)
Aikaikkuna: 1 year
|
User Satisfaction: Quebec User Evaluation of Satisfaction with assistive Technology version 2.0. Likert-type scale: Extremely dissatisfied - Dissatisfied - Slightly satisfied - Satisfied - Extremely satisfied. Extremely Satisfied is the best result. |
1 year
|
|
user satisfaction Psychosocial impact of assistive devices scale (PIADS)
Aikaikkuna: 1 year
|
User Satisfaction: Psychosocial impact of assistive devices scale.
Likert-type scale -3, -2, -1, 0, 1, 2, 3. 3 is best result.
|
1 year
|
|
Stability of BCI performance: impedance
Aikaikkuna: 1 year
|
Longitudinally follow the electrode impedance (in Ω), to assess their stability throughout the day and across the weeks and months after implantation.
|
1 year
|
|
Stability of BCI performance: signal dynamics
Aikaikkuna: 1 year
|
Longitudinally follow the raw signal dynamics (in µV) of neural signals, to assess their stability throughout the day and across the weeks and months after implantation.
|
1 year
|
|
Stability of BCI performance: task-related modulation
Aikaikkuna: 1 year
|
Longitudinally follow the task-related modulation in power (in µV), to assess their stability throughout the day and across the weeks and months after implantation.
|
1 year
|
|
Effects of somatosensory feedback on BCI Training and Performance: accuracy
Aikaikkuna: 1 year
|
Compare BCI control accuracy (in %), including variability and improvement therein before and after applying somatosensory feedback through electrocortical stimulation of the somatosensory cortex
|
1 year
|
|
Effects of somatosensory feedback on BCI Training and Performance: neural signals
Aikaikkuna: 1 year
|
Compare neural signal changes (in µV) in the sensorimotor areas before and after applying somatosensory feedback through electrocortical stimulation of the somatosensory cortex
|
1 year
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Assess device specifications for future, larger-scale, application of HD ECoG-BCIs
Aikaikkuna: 1 year
|
qualitative description on device specifications and experimental parameters, such as the specific decoder settings, for future, larger scale, application of HD ECoG-BCIs
|
1 year
|
|
Validation of software for independent home-use of advanced BCIs
Aikaikkuna: 1 year
|
Validation: Questionnaire to evaluate user satisfaction and ease of use of the home use software. Likert-type scale: fully disagree - disagree - neither agree or disagree - agree - fully agree - not applicable. Fully agree is the best result. |
1 year
|
Yhteistyökumppanit ja tutkijat
Sponsori
Tutkijat
- Päätutkija: Nick F Ramsey, PhD, UMC Utrecht
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Arvioitu)
Ensisijainen valmistuminen (Arvioitu)
Opintojen valmistuminen (Arvioitu)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
- Neurologiset ilmenemismuodot
- Keskushermoston sairaudet
- Hermoston sairaudet
- Haavat ja vammat
- Trauma, hermosto
- Selkäydinsairaudet
- Halvaus
- Patologiset tilat, merkit ja oireet
- Merkit ja oireet
- Selkäytimen vammat
- Quadriplegia
- Diagnostiikkatekniikat ja menettelyt
- Diagnoosi
- Diagnostiikkatekniikat, neurologiset
- Elektrodiagnoosi
- Sähkökortikografia
Muut tutkimustunnusnumerot
- NL-009756
- METC nummer 25-211 (Muu tunniste: NedMec)
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
IPD-suunnitelman kuvaus
IPD-jaon aikakehys
IPD-jaon käyttöoikeuskriteerit
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .