Efficacy and Safety of Simultaneous Integrated Boost Radiotherapy in HR/VHR Prostate Cancer With EPLNI (SIB-VMAT)

3. července 2026 aktualizováno: Mohamed Alhefny Almashtouly, Ain Shams University

Prospective Evaluation of Efficacy and Safety of Simultaneous Integrated Boost (SIB-VMAT) Radiotherapy in HR/VHR Prostate Cancer With EPLNI

The aim of this study is to evaluate the efficacy and safety of hypofractionated simultaneous integrated boost volumetric arc radiation therapy (SIB - VMAT) for high-risk and very high-risk localized prostate cancer in terms of:

  1. Acute and late gastrointestinal and genitourinary toxicities.
  2. Evaluate the efficacy in terms of early bPFS.
  3. Dosimetric evaluation in terms of target coverage and organs at risk sparing

Přehled studie

Detailní popis

Background:

Despite the overwhelming success of hypofractionation for prostate-only radiotherapy, a substantial gap in high-level evidence exists regarding its application to elective pelvic lymph node irradiation. The pivotal trials establishing the 60 Gy/20 fraction standard (such as CHHiP and PROFIT) largely excluded extensive whole pelvic nodal irradiation. Consequently, there remains a lack of definitive, prospective data validating the safety and efficacy of a hypofractionated Simultaneous Integrated Boost (SIB) technique that concurrently delivers 44 Gy to the pelvic lymph nodes and 60 Gy to the prostate over 20 fractions. While modern image-guided, Volumetric Modulated Arc Therapy (VMAT) provides the dosimetric conformity required to spare organs at risk (OARs) such as the bladder and bowel, clinical confirmation of acute and late toxicities in the context of wide-field pelvic irradiation remains paramount.

Therefore, this prospective, single-arm trial is designed to address this critical evidence gap. By rigorously evaluating the GI and GU toxicity profiles and early biochemical control, this study seeks to validate the 4-week SIB protocol as a safe, efficacious, and resource-efficient standard of care for high-risk prostate cancer requiring elective pelvic nodal irradiation.

Objectives:

To evaluate the safety of hypofractionated SIB - VMAT radiation therapy in terms of acute and late GI and GU toxicities, and also evaluate the efficacy in terms of early bPFS, and lastly, dosimetric evaluation in terms of target coverage and OAR sparing Study Arms Single arm Population: Histologically confirmed localized prostatic adenocarcinoma with high and very high risk groups.

Primary Endpoint: Acute and late GIT & GU toxicities (according to CTCAE & RTOG).

Secondary Endpoints:

  1. To evaluate early biochemical control (serum PSA) at 6 and 12 months.
  2. To perform a dosimetric analysis of target coverage and of organs at risk (OARs) dose contains.

Significance α = 0.05 two-sided; power = 80%; minimum detectable HR = 0.65 Duration 12 months total (from IRB approval to submission of the manuscript).

Typ studie

Intervenční

Zápis (Odhadovaný)

30

Fáze

  • Fáze 2

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní kontakt

Studijní záloha kontaktů

Studijní místa

      • Cairo, Egypt
        • Nábor
        • Faculty of Medicine, Ain Shams University
        • Kontakt:
      • Shibīn al Kawm, Egypt
        • Nábor
        • Faculty of Medicine - Menoufia University
        • Kontakt:
      • Sohag, Egypt
        • Nábor
        • Faculty of Medicine - Sohag University
        • Kontakt:

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

  • Dospělý
  • Starší dospělý

Přijímá zdravé dobrovolníky

Ne

Popis

Inclusion Criteria:

  • Histologically confirmed adenocarcinoma of the prostate.
  • Classification as High-Risk (HR) or Very High-Risk (VHR) per NCCN guidelines (e.g., T3a+, PSA > 20 ng/mL, or Gleason Score 8-10).
  • Adequate baseline urinary function (IPSS \le 20).
  • Multiparametric MRI of the prostate.
  • CT Chest, Abdomen, and Pelvis.
  • Bone scan
  • Optional: PSMA-PET/CT to definitively exclude distant metastases (M1) and provide high-fidelity nodal assessment prior to treatment planning.

Exclusion Criteria:

  • Prior pelvic radiotherapy.
  • History of Inflammatory Bowel Disease (IBD) or active severe proctitis.
  • Presence of distant metastases.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Léčba
  • Přidělení: N/A
  • Intervenční model: Přiřazení jedné skupiny
  • Maskování: Žádné (otevřený štítek)

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Experimentální: SIB-VMAT radiation therapy

Patients with histopathologically confirmed prostatic adenocarcinoma staged as high-risk / very high-risk localized disease will receive radiotherapy using Simultaneous Integrated Boost Volumetric Modulated Arc Therapy (SIB-VMAT) over a total duration of 4 weeks (20 consecutive working days).

Target volumes:

PTV-1 (PTV 44 Gy) Prostate + Pelvic Lymph Node PTV (PLNI): 44 Gy delivered in 20 fractions (2.2 Gy/fraction), including the internal iliac, external iliac, obturator, presacral nodal stations, whole prostate, and SV.

PTV-2 (PTV 60 GY): 60 Gy delivered in 20 fractions (3 Gy/fraction), including the whole prostate and the base of the SV (proximal 1 cm).

Systemic Therapy is allowed during the study when indicated. Patients will receive long-term Androgen Deprivation Therapy (ADT) for a duration of 18-24 months. ADT will be initiated as neoadjuvant therapy 2-3 months prior to the commencement of radiotherapy.

Patients with histopathologically confirmed prostatic adenocarcinoma staged as high-risk / very high-risk localized disease will receive radiotherapy using Simultaneous Integrated Boost Volumetric Modulated Arc Therapy (SIB-VMAT) over a total duration of 4 weeks (20 consecutive working days). Target volumes: PTV-1 (PTV 44 Gy) Prostate + Pelvic Lymph Node PTV (PLNI): 44 Gy delivered in 20 fractions (2.2 Gy/fraction), including the internal iliac, external iliac, obturator, presacral nodal stations, whole prostate, and SV. PTV-2 (PTV 60 GY): 60 Gy delivered in 20 fractions (3 Gy/fraction), including the whole prostate and the base of the SV (proximal 1 cm). Systemic Therapy is allowed during the study when indicated. Patients will receive long-term Androgen Deprivation Therapy (ADT) for a duration of 18-24 months. ADT will be initiated as neoadjuvant therapy 2-3 months prior to the commencement of radiotherapy.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Acute and late GIT & GU toxicity
Časové okno: Day 1, Day 7, Day 14, Day 20 from radiation therapy start, then week 4, week 8, week 12 from radiation therapy end.
The incidence and severity of acute (during the radiation treatment and up to 3 months post-treatment) and late (after 3 months from finishing radiotherapy) gastrointestinal (GI) and genitourinary (GU) toxicities associated with the SIB-VMAT approach using CTCAE v5.0 and RTOG scale.
Day 1, Day 7, Day 14, Day 20 from radiation therapy start, then week 4, week 8, week 12 from radiation therapy end.

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Early biochemical progression-free survival (bPFS)
Časové okno: Day 1, Month 3, Month 6 and Month 12, from radiation therapy end.
Early biochemical control in terms of the serial measurement of serum PSA levels.
Day 1, Month 3, Month 6 and Month 12, from radiation therapy end.
Dosimetric plan evaluation
Časové okno: Baseline (Day 1 of radiation therapy start).
  1. Dosimetric analysis of planning target volume coverage (PTV ): at least 95% of the volume must be covered with 95% of the prescribed radiation dose.
  2. Dosimetric analysis of organs at risk (OAR) dose constraints, including rectum, urinary bladder, bowel, femoral heads, and penile bulb radiation doses, according to Quantec and Chipp trial dose constraints.
Baseline (Day 1 of radiation therapy start).

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

1. srpna 2025

Primární dokončení (Odhadovaný)

1. září 2026

Dokončení studie (Odhadovaný)

1. listopadu 2026

Termíny zápisu do studia

První předloženo

28. června 2026

První předloženo, které splnilo kritéria kontroly kvality

3. července 2026

První zveřejněno (Aktuální)

9. července 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

9. července 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

3. července 2026

Naposledy ověřeno

1. června 2026

Více informací

Termíny související s touto studií

Další identifikační čísla studie

  • Soh-Med-26-6-12PD

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

NE

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

produkt vyrobený a vyvážený z USA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .