- ICH GCP
- Registr klinických studií v USA
- Klinická studie NCT07793916
3D Transthoracic Echocardiographic Evaluation on Tricuspid Regurgitation Progression and Clinical Outcomes in Patients With Cardiac Implantable Electronic Device (3DECHO-TR)
The goal of this observational study is to learn about the development and worsening of tricuspid regurgitation (TR) in patients who have cardiac implantable electronic devices (CIEDs).
The main objective is to compare left bundle branch area pacing (LBBaP) and leadless pacemakers against conventional pacemakers in terms of TR exacerbation.
Participants with these devices will have their retrospective and prospective clinical data analyzed and will undergo 3D transthoracic echocardiography to identify the exact mechanical causes of TR.
Přehled studie
Postavení
Intervence / Léčba
Detailní popis
As the use of cardiac implantable electronic devices(CIED) increases, CIED-related tricuspid regurgitation (CIED-related TR) is emerging as a critical clinical issue. CIED-related TR is one of the most common causes of primary TR, with a reported incidence ranging from approximately 10% to 30%. Numerous studies have confirmed that the severity of CIED-related TR is closely associated with poor prognosis.
This condition is particularly noteworthy because, unlike secondary TR, it possesses mechanical causes that are potentially intervenable. However, most studies published to date have reported results based on 2D echocardiography, which often leads to ambiguity in identifying the exact mechanisms behind the exacerbation of tricuspid regurgitation. Furthermore, there is a significant lack of data regarding TR associated with more recently introduced procedures, such as left bundle branch area pacing (LBBaP) and leadless pacemakers. Therefore, this study aims to perform 3D transthoracic echocardiography on patients with lead-based CIEDs and leadless pacemakers to comparatively analyze LBBaP and leadless pacemaker patients against conventional pacemaker patients in terms of TR exacerbation. By combining retrospective and prospective clinical data, this research will analyze the incidence and clinical impact of these conditions.
Typ studie
Zápis (Odhadovaný)
Kontakty a umístění
Studijní kontakt
- Jméno: Juwon Kim
- Telefonní číslo: 82+ 2-3410-3419
- E-mail: abcd186a@naver.com
Studijní místa
-
-
Seoul
-
Seoul, Seoul, Jižní Korea, 06351
- Nábor
- Samsung Medical Center
-
Kontakt:
- Juwon Kim
- Telefonní číslo: 82+ 2-3410-3419
- E-mail: abcd186a@naver.com
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dospělý
- Starší dospělý
Přijímá zdravé dobrovolníky
Metoda odběru vzorků
Studijní populace
Popis
Inclusion Criteria:
- Aged 19 years or older.
- Patients who are at least one year post-implantation of one of the following Cardiac Implantable Electronic Devices (CIEDs):
A. Permanent Pacemaker (PPM) B. Implantable Cardioverter-Defibrillator (ICD) C. Leadless Pacemaker
- Patients who underwent the implantation procedure on or after January 2022.
- Voluntary informed consent provided by the patient or their legal representative for the review of medical records and study-related data throughout the entire study period.
Exclusion Criteria:
- Patients with lead-based CIEDs whose leads do not cross the tricuspid annulus or those with two or more leads crossing the annulus.
- Patients whose baseline degree of tricuspid regurgitation (TR) cannot be assessed due to the absence of transthoracic echocardiography (TTE) performed within three months of the procedure.
- Patients with a history of ventricular lead extraction.
- Patients who have undergone tricuspid valve replacement surgery.
- Individuals who refuse active medical treatment.
Studijní plán
Jak je studie koncipována?
Detaily designu
Kohorty a intervence
Skupina / kohorta |
Intervence / Léčba |
|---|---|
|
A patient one year after receiving a cardiac implantable electronic device
Subjects aged 19 years or older who underwent de novo implantation of a leadless PPM or a cardiac implantable electronic device (PPM or ICD) at Samsung Medical Center between 2022 and 2025, and are at least one year post-implantation
|
The incidence and mechanisms of worsening tricuspid regurgitation are identified through three-dimensional echocardiography, and the resulting structural and functional changes in the heart are evaluated.
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Časové okno |
|---|---|
|
hospitalization due to heart failure
Časové okno: From the date of CIED implantation until the date of the first heart failure hospitalization or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
From the date of CIED implantation until the date of the first heart failure hospitalization or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
Sekundární výstupní opatření
Měření výsledku |
Časové okno |
|---|---|
|
incidence of CIED related, associated TR
Časové okno: Assessed at the time of the study 3D transthoracic echocardiography, performed at least 1 year after CIED implantation, up to 6 years after implantation.
|
Assessed at the time of the study 3D transthoracic echocardiography, performed at least 1 year after CIED implantation, up to 6 years after implantation.
|
|
re-admission due to any cause
Časové okno: From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
|
Tricuspid valve intervention
Časové okno: From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
|
transvenous lead extraction or reposition
Časové okno: From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
Spolupracovníci a vyšetřovatelé
Sponzor
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Primární dokončení (Odhadovaný)
Dokončení studie (Odhadovaný)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
- SMC 2026-01-010
- KCT0011605 (Jiný identifikátor: Korea National Institute of Health)
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .