- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07793916
3D Transthoracic Echocardiographic Evaluation on Tricuspid Regurgitation Progression and Clinical Outcomes in Patients With Cardiac Implantable Electronic Device (3DECHO-TR)
The goal of this observational study is to learn about the development and worsening of tricuspid regurgitation (TR) in patients who have cardiac implantable electronic devices (CIEDs).
The main objective is to compare left bundle branch area pacing (LBBaP) and leadless pacemakers against conventional pacemakers in terms of TR exacerbation.
Participants with these devices will have their retrospective and prospective clinical data analyzed and will undergo 3D transthoracic echocardiography to identify the exact mechanical causes of TR.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
As the use of cardiac implantable electronic devices(CIED) increases, CIED-related tricuspid regurgitation (CIED-related TR) is emerging as a critical clinical issue. CIED-related TR is one of the most common causes of primary TR, with a reported incidence ranging from approximately 10% to 30%. Numerous studies have confirmed that the severity of CIED-related TR is closely associated with poor prognosis.
This condition is particularly noteworthy because, unlike secondary TR, it possesses mechanical causes that are potentially intervenable. However, most studies published to date have reported results based on 2D echocardiography, which often leads to ambiguity in identifying the exact mechanisms behind the exacerbation of tricuspid regurgitation. Furthermore, there is a significant lack of data regarding TR associated with more recently introduced procedures, such as left bundle branch area pacing (LBBaP) and leadless pacemakers. Therefore, this study aims to perform 3D transthoracic echocardiography on patients with lead-based CIEDs and leadless pacemakers to comparatively analyze LBBaP and leadless pacemaker patients against conventional pacemaker patients in terms of TR exacerbation. By combining retrospective and prospective clinical data, this research will analyze the incidence and clinical impact of these conditions.
Type d'étude
Inscription (Estimé)
Contacts et emplacements
Coordonnées de l'étude
- Nom: Juwon Kim
- Numéro de téléphone: 82+ 2-3410-3419
- E-mail: abcd186a@naver.com
Lieux d'étude
-
-
Seoul
-
Seoul, Seoul, Corée du Sud, 06351
- Recrutement
- Samsung Medical Center
-
Contact:
- Juwon Kim
- Numéro de téléphone: 82+ 2-3410-3419
- E-mail: abcd186a@naver.com
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- Aged 19 years or older.
- Patients who are at least one year post-implantation of one of the following Cardiac Implantable Electronic Devices (CIEDs):
A. Permanent Pacemaker (PPM) B. Implantable Cardioverter-Defibrillator (ICD) C. Leadless Pacemaker
- Patients who underwent the implantation procedure on or after January 2022.
- Voluntary informed consent provided by the patient or their legal representative for the review of medical records and study-related data throughout the entire study period.
Exclusion Criteria:
- Patients with lead-based CIEDs whose leads do not cross the tricuspid annulus or those with two or more leads crossing the annulus.
- Patients whose baseline degree of tricuspid regurgitation (TR) cannot be assessed due to the absence of transthoracic echocardiography (TTE) performed within three months of the procedure.
- Patients with a history of ventricular lead extraction.
- Patients who have undergone tricuspid valve replacement surgery.
- Individuals who refuse active medical treatment.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Cohortes et interventions
Groupe / Cohorte |
Intervention / Traitement |
|---|---|
|
A patient one year after receiving a cardiac implantable electronic device
Subjects aged 19 years or older who underwent de novo implantation of a leadless PPM or a cardiac implantable electronic device (PPM or ICD) at Samsung Medical Center between 2022 and 2025, and are at least one year post-implantation
|
The incidence and mechanisms of worsening tricuspid regurgitation are identified through three-dimensional echocardiography, and the resulting structural and functional changes in the heart are evaluated.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Délai |
|---|---|
|
hospitalization due to heart failure
Délai: From the date of CIED implantation until the date of the first heart failure hospitalization or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
From the date of CIED implantation until the date of the first heart failure hospitalization or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
Mesures de résultats secondaires
Mesure des résultats |
Délai |
|---|---|
|
incidence of CIED related, associated TR
Délai: Assessed at the time of the study 3D transthoracic echocardiography, performed at least 1 year after CIED implantation, up to 6 years after implantation.
|
Assessed at the time of the study 3D transthoracic echocardiography, performed at least 1 year after CIED implantation, up to 6 years after implantation.
|
|
re-admission due to any cause
Délai: From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
|
Tricuspid valve intervention
Délai: From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
|
transvenous lead extraction or reposition
Délai: From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
Collaborateurs et enquêteurs
Parrainer
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- SMC 2026-01-010
- KCT0011605 (Autre identifiant: Korea National Institute of Health)
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .