Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

First-in-human Clinical Trial to Assess Safety and Efficacy of the CardiaZn Bioresorbable Stent in Children With Pulmonary Artery Stenosis and Aortic Coarctation (Pediasorb)

26. maj 2026 opdateret af: PediaStent LLC

A Prospective Multi-Center, Single Arm, Open Label, Pivotal Clinical Study Designed to Assess the Safety, Performance, and Efficacy of the CardiaZn Stent in the Treatment of Pediatric Aortic Coarctation and Pulmonary Artery Stenosis

This study evaluates the safety and effectiveness of the CardiaZn stent, a novel bioresorbable stent designed specifically for infants and children with congenital cardiovascular conditions. Unlike permanent metal stents, the CardiaZn stent is designed to open narrowed blood vessels and then gradually dissolve, leaving nothing permanently behind. This allows the vessel to grow naturally with the child over time.

The study will enroll children under 9 years of age diagnosed with either pulmonary artery stenosis - a narrowing of the arteries that carry blood from the heart to the lungs - or aortic coarctation - a narrowing of the main artery carrying blood from the heart to the body. Both conditions currently require repeated interventions as children grow, since existing permanent stents cannot accommodate natural vessel growth.

Participants will receive the CardiaZn stent during a standard cardiac catheterization procedure and will be followed for 5 years to assess vessel patency, device performance, and long-term safety outcomes.

Studieoversigt

Status

Ikke rekrutterer endnu

Intervention / Behandling

Detaljeret beskrivelse

Background and Clinical Need Pulmonary artery stenosis (PAS) and aortic coarctation (CoA) are among the most common congenital cardiovascular conditions requiring catheter-based intervention in infants and children. Current standard of care involves balloon dilation and implantation of permanent metallic stents. While effective in the short term, permanent stents present a significant limitation in pediatric patients: they cannot accommodate somatic growth, necessitating repeated balloon dilations and re-interventions throughout childhood. Furthermore, permanent metallic implants preclude normal vessel remodeling, restrict MRI imaging quality, and complicate future surgical access.

The unmet clinical need is substantial. A bioresorbable stent that provides acute vessel support, maintains patency through the critical healing phase, and then completely resorbs - leaving no permanent implant - would represent a paradigm shift in the management of pediatric congenital cardiovascular stenoses.

Device Description The CardiaZn stent is a bioresorbable endovascular stent fabricated from a zinc-silver (ZnAg) alloy. Zinc is an essential trace element with well-characterized metabolic pathways, and its corrosion byproducts are biocompatible and cleared through normal physiological mechanisms. The addition of silver enhances mechanical properties including radial strength and corrosion kinetics. The device is balloon-expandable and delivered via standard cardiac catheterization technique.

The ZnAg alloy platform distinguishes CardiaZn from polymer-based bioresorbable scaffolds, which have demonstrated limitations in radial strength and degradation kinetics, and from magnesium-based platforms, which resorb too rapidly for the intended application window. The zinc-silver system is designed to provide sufficient radial support through the vessel healing phase, with a resorption timeline aligned to the biological requirements of pediatric vascular remodeling.

The device is drug-free, relying entirely on the mechanical and biological properties of the ZnAg alloy to achieve its clinical objectives. This drug-free positioning is supported by pediatric case data from magnesium-based platforms demonstrating that bioresorbable metal scaffolds can achieve clinically meaningful outcomes without pharmacological augmentation.

Study Rationale Preclinical evaluation of the CardiaZn stent has included comprehensive in vitro testing, biocompatibility assessment per ISO 10993 standards, and a GLP animal study. Results have demonstrated adequate radial strength, biocompatible corrosion byproduct profile, and vessel patency consistent with the intended clinical application. These data support proceeding to first-in-human evaluation under an FDA Investigational Device Exemption.

Prior FDA engagement through the TAP Pre-Submission program (Q-Submission U230126-A010) established alignment on study design, endpoint selection, and statistical approach prior to IDE submission.

Study Design PEDIASORB is a prospective, multicenter, single-arm, open-label, pivotal clinical study. A total of 45 eligible subjects will be enrolled at up to 11 investigational sites. The study population includes subjects aged under 9 years presenting with hemodynamically significant discrete aortic coarctation or pulmonary artery stenosis.

To ensure balanced representation of both indications, neither the pulmonary artery stenosis nor the aortic coarctation population may contribute more than 70% of total enrollment, ensuring a minimum of 14 subjects per treatment location. At least 50% of enrollments will occur at United States investigational sites.

Patients will be screened for pre-operative eligibility within 60 days prior to the index procedure. Following confirmation of intraoperative eligibility criteria via angiography, eligible subjects will undergo implantation of the CardiaZn stent via standard cardiac catheterization technique.

Follow-Up All subjects will be followed for 5 years post-procedure. Follow-up visits are scheduled at hospital discharge and at months 1, 3, 6, and 12, and annually through year 5. Each follow-up visit includes physical examination, laboratory testing, health status assessment, imaging evaluation, and review of concomitant medications and procedures. CT angiography will be performed in all subjects at 6 months post-procedure.

Adverse events will be collected from initial informed consent through study exit.

Primary Endpoints

The co-primary endpoints are:

Device success at the index procedure, defined as successful delivery and deployment of the CardiaZn stent with achievement of adequate vessel patency as assessed by angiography Freedom from pre-defined procedure- and device-related serious adverse events of interest through 6 months post-procedure

Secondary Endpoints Secondary endpoints include assessment of vessel patency, peak-to-peak pressure gradient, vessel diameter, and freedom from re-intervention through 5 years of follow-up. Long-term safety will be assessed through collection of all adverse events, serious adverse events, and device-related complications through study exit.

Statistical Considerations The study is designed as a single-arm pivotal trial with performance goal comparisons against pre-specified objective performance criteria derived from published literature and historical data for the current standard of care. The sample size of 45 subjects provides adequate statistical power to test the co-primary endpoints at the pre-specified significance level. A formal statistical analysis plan has been developed and is included as an attachment to the IDE submission.

Data Safety Monitoring An independent Data Safety Monitoring Board (DSMB) will provide ongoing oversight of subject safety throughout the trial. A Clinical Events Committee (CEC) will provide independent adjudication of all adverse events and endpoints. Interim analyses will be conducted per the DSMB charter.

Regulatory Background The CardiaZn stent is an investigational device. This study is being conducted under FDA IDE number U230126. Prior FDA engagement was conducted through the TAP Pre-Submission program. The study is sponsored by PediaStent and conducted in accordance with applicable FDA regulations, Good Clinical Practice guidelines, and the principles of the Declaration of Helsinki.

Undersøgelsestype

Interventionel

Tilmelding (Anslået)

45

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiekontakt

  • Navn: Timothy Moran President
  • Telefonnummer: 8886916161
  • E-mail: trm242@gmail.com

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

  • Barn

Tager imod sunde frivillige

Ingen

Beskrivelse

Inclusion Criteria:

  • Subject is aged less than 9 years at the time of the index procedure
  • Subject presents with hemodynamically significant discrete aortic coarctation or pulmonary artery stenosis requiring catheter-based intervention
  • Subject meets angiographic eligibility criteria at the time of the index procedure as assessed by the interventional cardiologist
  • Subject's legally authorized representative has provided written informed consent prior to any study-related procedures
  • Subject's physician has determined that catheter-based intervention is clinically indicated
  • Target vessel anatomy is suitable for stent implantation as assessed by the operator

Exclusion Criteria:

  • Subject has complex aortic arch hypoplasia or long segment coarctation not amenable to stent therapy
  • Subject has a known allergy or hypersensitivity to zinc or silver
  • Subject has active systemic infection at the time of the index procedure
  • Subject has a contraindication to cardiac catheterization or general anesthesia
  • Subject has previously received a stent at the target vessel segment
  • Subject has a comorbid condition that in the opinion of the investigator would preclude safe participation in the study or confound study results
  • Subject is currently enrolled in another investigational device or drug study that has not completed its primary endpoint
  • Subject has a life expectancy of less than 12 months in the opinion of the investigator

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: N/A
  • Interventionel model: Enkelt gruppeopgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: CardiaZn Bioresorbable Stent
All enrolled subjects will receive the CardiaZn bioresorbable zinc-silver alloy stent, delivered via standard cardiac catheterization technique for the treatment of hemodynamically significant aortic coarctation or pulmonary artery stenosis in subjects aged under 9 years.
The CardiaZn stent is a balloon-expandable bioresorbable endovascular stent fabricated from a zinc-silver (ZnAg) alloy. Zinc is an essential trace element with well-characterized metabolic pathways and biocompatible corrosion byproduct profile. The addition of silver enhances radial strength and optimizes corrosion kinetics for the intended resorption timeline. The device is delivered via standard cardiac catheterization technique under fluoroscopic guidance and is designed to provide acute mechanical support of the stenotic vessel segment following balloon dilation, then gradually resorb completely over time leaving no permanent implant. The device is drug-free.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Device Success at Index Procedure
Tidsramme: At index procedure (Day 0)
Successful delivery and deployment of the CardiaZn stent with achievement of adequate vessel patency defined as less than 30% residual diameter stenosis as assessed by quantitative angiography
At index procedure (Day 0)
Freedom from Device- and Procedure-Related Serious Adverse Events
Tidsramme: 6 months post-procedure
Freedom from pre-defined procedure- and device-related serious adverse events of interest including vessel perforation, stent thrombosis, stent embolization, stent fracture, and target vessel reintervention
6 months post-procedure

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Peak-to-Peak Pressure Gradient
Tidsramme: Baseline, 6 months, 12 months, annually through 5 years
Change in peak-to-peak pressure gradient across the treated vessel segment as measured by cardiac catheterization
Baseline, 6 months, 12 months, annually through 5 years
Minimum Lumen Diameter
Tidsramme: Baseline, 6 months, 12 months, annually through 5 years
Minimum lumen diameter of the treated vessel segment as assessed by quantitative angiography or CT angiography
Baseline, 6 months, 12 months, annually through 5 years
Freedom from Target Vessel Reintervention
Tidsramme: 6 months, 12 months, annually through 5 years
Freedom from any reintervention at the target vessel segment including repeat balloon dilation, repeat stenting, or surgical intervention
6 months, 12 months, annually through 5 years
Freedom from Device- and Procedure-Related Serious Adverse Events
Tidsramme: 12 months, annually through 5 years
Freedom from pre-defined procedure- and device-related serious adverse events of interest
12 months, annually through 5 years
Stent Patency
Tidsramme: 6 months, 12 months, annually through 5 years
Binary assessment of stent patency defined as absence of significant in-stent restenosis greater than 50% diameter stenosis as assessed by CT angiography or cardiac catheterization
6 months, 12 months, annually through 5 years
Somatic Growth Accommodation
Tidsramme: 12 months, annually through 5 years
Assessment of vessel diameter growth relative to somatic growth parameters including height and weight over the follow-up period
12 months, annually through 5 years
All-Cause Mortality
Tidsramme: 30 days, 6 months, 12 months, annually through 5 years
Death from any cause
30 days, 6 months, 12 months, annually through 5 years
Device-Related Adverse Events
Tidsramme: From index procedure through 5 years
All adverse events adjudicated as device-related by the independent Clinical Events Committee
From index procedure through 5 years

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Sponsor

Efterforskere

  • Studieleder: Daniel Levi, MD, University of California, Los Angeles

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Anslået)

1. oktober 2026

Primær færdiggørelse (Anslået)

1. oktober 2031

Studieafslutning (Anslået)

1. december 2031

Datoer for studieregistrering

Først indsendt

26. maj 2026

Først indsendt, der opfyldte QC-kriterier

26. maj 2026

Først opslået (Faktiske)

4. juni 2026

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

4. juni 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

26. maj 2026

Sidst verificeret

1. maj 2026

Mere information

Begreber relateret til denne undersøgelse

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

INGEN

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ja

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med CardiaZn Bioresorbable Stent

Abonner