First-in-human Clinical Trial to Assess Safety and Efficacy of the CardiaZn Bioresorbable Stent in Children With Pulmonary Artery Stenosis and Aortic Coarctation (Pediasorb)

2026年5月26日 更新者:PediaStent LLC

A Prospective Multi-Center, Single Arm, Open Label, Pivotal Clinical Study Designed to Assess the Safety, Performance, and Efficacy of the CardiaZn Stent in the Treatment of Pediatric Aortic Coarctation and Pulmonary Artery Stenosis

This study evaluates the safety and effectiveness of the CardiaZn stent, a novel bioresorbable stent designed specifically for infants and children with congenital cardiovascular conditions. Unlike permanent metal stents, the CardiaZn stent is designed to open narrowed blood vessels and then gradually dissolve, leaving nothing permanently behind. This allows the vessel to grow naturally with the child over time.

The study will enroll children under 9 years of age diagnosed with either pulmonary artery stenosis - a narrowing of the arteries that carry blood from the heart to the lungs - or aortic coarctation - a narrowing of the main artery carrying blood from the heart to the body. Both conditions currently require repeated interventions as children grow, since existing permanent stents cannot accommodate natural vessel growth.

Participants will receive the CardiaZn stent during a standard cardiac catheterization procedure and will be followed for 5 years to assess vessel patency, device performance, and long-term safety outcomes.

調査の概要

状態

まだ募集していません

詳細な説明

Background and Clinical Need Pulmonary artery stenosis (PAS) and aortic coarctation (CoA) are among the most common congenital cardiovascular conditions requiring catheter-based intervention in infants and children. Current standard of care involves balloon dilation and implantation of permanent metallic stents. While effective in the short term, permanent stents present a significant limitation in pediatric patients: they cannot accommodate somatic growth, necessitating repeated balloon dilations and re-interventions throughout childhood. Furthermore, permanent metallic implants preclude normal vessel remodeling, restrict MRI imaging quality, and complicate future surgical access.

The unmet clinical need is substantial. A bioresorbable stent that provides acute vessel support, maintains patency through the critical healing phase, and then completely resorbs - leaving no permanent implant - would represent a paradigm shift in the management of pediatric congenital cardiovascular stenoses.

Device Description The CardiaZn stent is a bioresorbable endovascular stent fabricated from a zinc-silver (ZnAg) alloy. Zinc is an essential trace element with well-characterized metabolic pathways, and its corrosion byproducts are biocompatible and cleared through normal physiological mechanisms. The addition of silver enhances mechanical properties including radial strength and corrosion kinetics. The device is balloon-expandable and delivered via standard cardiac catheterization technique.

The ZnAg alloy platform distinguishes CardiaZn from polymer-based bioresorbable scaffolds, which have demonstrated limitations in radial strength and degradation kinetics, and from magnesium-based platforms, which resorb too rapidly for the intended application window. The zinc-silver system is designed to provide sufficient radial support through the vessel healing phase, with a resorption timeline aligned to the biological requirements of pediatric vascular remodeling.

The device is drug-free, relying entirely on the mechanical and biological properties of the ZnAg alloy to achieve its clinical objectives. This drug-free positioning is supported by pediatric case data from magnesium-based platforms demonstrating that bioresorbable metal scaffolds can achieve clinically meaningful outcomes without pharmacological augmentation.

Study Rationale Preclinical evaluation of the CardiaZn stent has included comprehensive in vitro testing, biocompatibility assessment per ISO 10993 standards, and a GLP animal study. Results have demonstrated adequate radial strength, biocompatible corrosion byproduct profile, and vessel patency consistent with the intended clinical application. These data support proceeding to first-in-human evaluation under an FDA Investigational Device Exemption.

Prior FDA engagement through the TAP Pre-Submission program (Q-Submission U230126-A010) established alignment on study design, endpoint selection, and statistical approach prior to IDE submission.

Study Design PEDIASORB is a prospective, multicenter, single-arm, open-label, pivotal clinical study. A total of 45 eligible subjects will be enrolled at up to 11 investigational sites. The study population includes subjects aged under 9 years presenting with hemodynamically significant discrete aortic coarctation or pulmonary artery stenosis.

To ensure balanced representation of both indications, neither the pulmonary artery stenosis nor the aortic coarctation population may contribute more than 70% of total enrollment, ensuring a minimum of 14 subjects per treatment location. At least 50% of enrollments will occur at United States investigational sites.

Patients will be screened for pre-operative eligibility within 60 days prior to the index procedure. Following confirmation of intraoperative eligibility criteria via angiography, eligible subjects will undergo implantation of the CardiaZn stent via standard cardiac catheterization technique.

Follow-Up All subjects will be followed for 5 years post-procedure. Follow-up visits are scheduled at hospital discharge and at months 1, 3, 6, and 12, and annually through year 5. Each follow-up visit includes physical examination, laboratory testing, health status assessment, imaging evaluation, and review of concomitant medications and procedures. CT angiography will be performed in all subjects at 6 months post-procedure.

Adverse events will be collected from initial informed consent through study exit.

Primary Endpoints

The co-primary endpoints are:

Device success at the index procedure, defined as successful delivery and deployment of the CardiaZn stent with achievement of adequate vessel patency as assessed by angiography Freedom from pre-defined procedure- and device-related serious adverse events of interest through 6 months post-procedure

Secondary Endpoints Secondary endpoints include assessment of vessel patency, peak-to-peak pressure gradient, vessel diameter, and freedom from re-intervention through 5 years of follow-up. Long-term safety will be assessed through collection of all adverse events, serious adverse events, and device-related complications through study exit.

Statistical Considerations The study is designed as a single-arm pivotal trial with performance goal comparisons against pre-specified objective performance criteria derived from published literature and historical data for the current standard of care. The sample size of 45 subjects provides adequate statistical power to test the co-primary endpoints at the pre-specified significance level. A formal statistical analysis plan has been developed and is included as an attachment to the IDE submission.

Data Safety Monitoring An independent Data Safety Monitoring Board (DSMB) will provide ongoing oversight of subject safety throughout the trial. A Clinical Events Committee (CEC) will provide independent adjudication of all adverse events and endpoints. Interim analyses will be conducted per the DSMB charter.

Regulatory Background The CardiaZn stent is an investigational device. This study is being conducted under FDA IDE number U230126. Prior FDA engagement was conducted through the TAP Pre-Submission program. The study is sponsored by PediaStent and conducted in accordance with applicable FDA regulations, Good Clinical Practice guidelines, and the principles of the Declaration of Helsinki.

研究の種類

介入

入学 (推定)

45

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

  • 名前:Timothy Moran President
  • 電話番号:8886916161
  • メールtrm242@gmail.com

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

健康ボランティアの受け入れ

いいえ

説明

Inclusion Criteria:

  • Subject is aged less than 9 years at the time of the index procedure
  • Subject presents with hemodynamically significant discrete aortic coarctation or pulmonary artery stenosis requiring catheter-based intervention
  • Subject meets angiographic eligibility criteria at the time of the index procedure as assessed by the interventional cardiologist
  • Subject's legally authorized representative has provided written informed consent prior to any study-related procedures
  • Subject's physician has determined that catheter-based intervention is clinically indicated
  • Target vessel anatomy is suitable for stent implantation as assessed by the operator

Exclusion Criteria:

  • Subject has complex aortic arch hypoplasia or long segment coarctation not amenable to stent therapy
  • Subject has a known allergy or hypersensitivity to zinc or silver
  • Subject has active systemic infection at the time of the index procedure
  • Subject has a contraindication to cardiac catheterization or general anesthesia
  • Subject has previously received a stent at the target vessel segment
  • Subject has a comorbid condition that in the opinion of the investigator would preclude safe participation in the study or confound study results
  • Subject is currently enrolled in another investigational device or drug study that has not completed its primary endpoint
  • Subject has a life expectancy of less than 12 months in the opinion of the investigator

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:なし
  • 介入モデル:単一グループの割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:CardiaZn Bioresorbable Stent
All enrolled subjects will receive the CardiaZn bioresorbable zinc-silver alloy stent, delivered via standard cardiac catheterization technique for the treatment of hemodynamically significant aortic coarctation or pulmonary artery stenosis in subjects aged under 9 years.
The CardiaZn stent is a balloon-expandable bioresorbable endovascular stent fabricated from a zinc-silver (ZnAg) alloy. Zinc is an essential trace element with well-characterized metabolic pathways and biocompatible corrosion byproduct profile. The addition of silver enhances radial strength and optimizes corrosion kinetics for the intended resorption timeline. The device is delivered via standard cardiac catheterization technique under fluoroscopic guidance and is designed to provide acute mechanical support of the stenotic vessel segment following balloon dilation, then gradually resorb completely over time leaving no permanent implant. The device is drug-free.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Device Success at Index Procedure
時間枠:At index procedure (Day 0)
Successful delivery and deployment of the CardiaZn stent with achievement of adequate vessel patency defined as less than 30% residual diameter stenosis as assessed by quantitative angiography
At index procedure (Day 0)
Freedom from Device- and Procedure-Related Serious Adverse Events
時間枠:6 months post-procedure
Freedom from pre-defined procedure- and device-related serious adverse events of interest including vessel perforation, stent thrombosis, stent embolization, stent fracture, and target vessel reintervention
6 months post-procedure

二次結果の測定

結果測定
メジャーの説明
時間枠
Peak-to-Peak Pressure Gradient
時間枠:Baseline, 6 months, 12 months, annually through 5 years
Change in peak-to-peak pressure gradient across the treated vessel segment as measured by cardiac catheterization
Baseline, 6 months, 12 months, annually through 5 years
Minimum Lumen Diameter
時間枠:Baseline, 6 months, 12 months, annually through 5 years
Minimum lumen diameter of the treated vessel segment as assessed by quantitative angiography or CT angiography
Baseline, 6 months, 12 months, annually through 5 years
Freedom from Target Vessel Reintervention
時間枠:6 months, 12 months, annually through 5 years
Freedom from any reintervention at the target vessel segment including repeat balloon dilation, repeat stenting, or surgical intervention
6 months, 12 months, annually through 5 years
Freedom from Device- and Procedure-Related Serious Adverse Events
時間枠:12 months, annually through 5 years
Freedom from pre-defined procedure- and device-related serious adverse events of interest
12 months, annually through 5 years
Stent Patency
時間枠:6 months, 12 months, annually through 5 years
Binary assessment of stent patency defined as absence of significant in-stent restenosis greater than 50% diameter stenosis as assessed by CT angiography or cardiac catheterization
6 months, 12 months, annually through 5 years
Somatic Growth Accommodation
時間枠:12 months, annually through 5 years
Assessment of vessel diameter growth relative to somatic growth parameters including height and weight over the follow-up period
12 months, annually through 5 years
All-Cause Mortality
時間枠:30 days, 6 months, 12 months, annually through 5 years
Death from any cause
30 days, 6 months, 12 months, annually through 5 years
Device-Related Adverse Events
時間枠:From index procedure through 5 years
All adverse events adjudicated as device-related by the independent Clinical Events Committee
From index procedure through 5 years

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • スタディディレクター:Daniel Levi, MD、University of California, Los Angeles

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (推定)

2026年10月1日

一次修了 (推定)

2031年10月1日

研究の完了 (推定)

2031年12月1日

試験登録日

最初に提出

2026年5月26日

QC基準を満たした最初の提出物

2026年5月26日

最初の投稿 (実際)

2026年6月4日

学習記録の更新

投稿された最後の更新 (実際)

2026年6月4日

QC基準を満たした最後の更新が送信されました

2026年5月26日

最終確認日

2026年5月1日

詳しくは

本研究に関する用語

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

はい

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

CardiaZn Bioresorbable Stentの臨床試験

購読する