- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT00783679
The Feasibility and Accuracy of Exhaled CO2 to Measure Cardiac Output in Ventilated Patients Without Tracheal Intubation
Determining the Feasibility and Accuracy of Exhaled CO2 to Measure Cardiac Output in Ventilated Patients Without Tracheal Intubation
The purpose of this study is to test the accuracy of a new noninvasive way to measure how much blood our heart pumps per minute. This new way measures the heart's pumping activity from outside the body, instead of breaking the skin and measuring it from the inside.
Subjects will breathe normally through a mask while we record how fast and how much air they are breathing. We will have them "re-breathe" some of the air they breathed out by adjusting the ventilator. During this time, we will use the air breathed out to calculate how much blood per minute the subject's heart is pumping. We will also measure how much blood the heart is pumping at this time by injecting fluid into the catheter in the neck and then drawing about 1 teaspoon of blood from the catheters in the neck and arm. We will compare the calculated and measured values of the amount of blood pumped out of the heart for accuracy.
After we complete this procedure, we will remove the mask and allow you to rest for 10-30min. Following the rest period, we will repeat the process and collect a second set of measurements. We will draw a total of 4 teaspoons of blood for the study.
If you cannot comfortably breathe along with the ventilator, we will withdraw you from the study. If you want to stop taking part in the study at any time, let the study doctor know that you wish to withdraw. We will take off the mask, and your time in the study will end. This decision will not affect your regular medical care.
Studienübersicht
Status
Bedingungen
Intervention / Behandlung
Studientyp
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
Massachusetts
-
Boston, Massachusetts, Vereinigte Staaten, 02114
- Massachusetts General Hospital
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- Patient is already monitored with a pulmonary artery catheter and arterial line (not for the purpose of this study);
- Hemodynamic stability.
Exclusion Criteria:
- Patients with facial deformity, heavy beard or moustache which prevents good seal between the mask and the face;
- Patients who have central nervous system disorders that might be adversely affected by CO2 rebreathing, such as head trauma patients with increased intracranial pressure;
- Patients with severe tricuspid regurgitation;
- Patients with intra-cardiac shunts;
- Patients who cannot cooperate and synchronize with the ventilator;
- Patients with unstable respiratory conditions, such as acute respiratory failure;
- Patients who have claustrophobia and cannot wear the mask.
- Patients with aortic stenosis.
- Patients with left main coronary artery disease.
- Pregnancy.
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Zuteilung: N / A
- Interventionsmodell: Einzelgruppenzuweisung
- Maskierung: Keine (Offenes Etikett)
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Sonstiges: 1
Twenty adult spontaneously breathing patients without intubation and mechanical ventilation recruited from the cardiac catheterization laboratory.
All will be post-heart-transplant patients coming for yearly evaluation.
|
Measurement of cardiac output and simultaneous blood sampling. The subjects' cardiac output will be measured by NICO device and also by thermodilution method. Simultaneously blood samples will be drawn from the pulmonary artery catheter and arterial line. The calculated and measured cardiac output values will be compared for accuracy. |
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Zeitfenster |
|---|---|
|
To test the feasibility and accuracy of using NICO to measure cardiac output in ventilator assisted patients without tracheal intubation.
Zeitfenster: 1 year
|
1 year
|
Mitarbeiter und Ermittler
Sponsor
Ermittler
- Hauptermittler: Robert Kacmarek, PhD, RRT, Massachusetts General Hospital
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn
Primärer Abschluss (Tatsächlich)
Studienabschluss (Tatsächlich)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Schätzen)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Schätzen)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Andere Studien-ID-Nummern
- 2007-P-000222
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Produkt, das in den USA hergestellt und aus den USA exportiert wird
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .