The Multi-Sensor Distance Accuracy Study
15. September 2014 aktualisiert von: W Kenneth Ward MD, Oregon Health and Science University
The Accuracy Benefit of Dual vs Single Amperometric Glucose Sensors in Persons With Type 1 Diabetes: Effect of Inter-sensor Distance
The purpose of the study is to test the accuracy benefit of having two glucose sensors (over one sensor alone) when they are positioned: 2mm, 10mm, 20mm, or 30mm apart.
It is not yet known how close two sensors can be and still work correctly.
Studienübersicht
Status
Abgeschlossen
Bedingungen
Detaillierte Beschreibung
An artificial pancreas system will likely require multiple glucose sensing elements to function safely.
It is not yet known how close two glucose sensors can be placed and still work properly.
Meaning, if one is reading inaccurately,and the other is positioned adjacent to it, will it read inaccurately also, defeating the purpose of having two sensors.
Twenty adult subjects with Type 1 diabetes will wear four Medtronic REAL-Time glucose sensors during two separate 10-hour studies.
The inter-sensor distances of each pair to be tested will be: 2, 10, 20, and 30mm apart.
The sensors will be inserted the day prior to the study day to allow for signal stabilization and calibration.
During the study day, arterialized venous blood will be drawn every 15 minutes to measure blood glucose.
The sensor values and interstitial values will be recorded from each sensor receiver at each time point.
Subjects will be fed two standardized meals and given pre-meal insulin based on their typical insulin to carbohydrate ratio.
Studientyp
Beobachtungs
Einschreibung (Tatsächlich)
20
Kontakte und Standorte
Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.
Studienorte
-
-
Oregon
-
Portland, Oregon, Vereinigte Staaten, 97239
- Oregon Health & Science University
-
-
Teilnahmekriterien
Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.
Zulassungskriterien
Studienberechtigtes Alter
18 Jahre bis 65 Jahre (Erwachsene, Älterer Erwachsener)
Akzeptiert gesunde Freiwillige
Nein
Studienberechtigte Geschlechter
Alle
Probenahmeverfahren
Nicht-Wahrscheinlichkeitsprobe
Studienpopulation
clinical practice Type 1 patients
Beschreibung
Inclusion Criteria:
- Type 1 diabetes mellitus diagnosed for at least 6 months
- Current usage of multiple daily injections or subcutaneous insulin pump treatment
- Age 18-65 years
- HbA1c of 6.0 - 9.5% at screening visit
- BMI 21-35
- Willingness to follow all study procedures, including attending all clinic visits
- Willingness to sign informed consent and HIPAA documents
Exclusion Criteria: Subjects presenting with any of the following will not be included in the study.
- Pregnancy or Lactation: for women of childbearing potential there is a requirement for a negative urine pregnancy test.
- Renal insufficiency (serum creatinine of 2.0 mg/dL or greater). Serum ALT or AST equal to or greater than 3 times the upper limit of normal; hepatic synthetic insufficiency as defined as a serum albumin of less the 3.3 g/dL; or serum bilirubin of over 2.
- Hematocrit of less than or equal to 34%.
- Congestive heart failure, NYHA class III or IV.
- Visual impairment preventing reading of glucose meter values.
- Active coronary artery disease as manifested by unstable angina, or a myocardial infarction or therapeutic coronary percutaneous procedure (e.g., PTCA, stent placement) or CABG within the past 4 months.
- Active foot ulceration.
- Severe peripheral arterial disease characterized by ischemic rest pain or severe claudication.
- Cerebrovascular accident within the past 6 months.
- Active alcohol abuse, substance abuse, or severe mental illness (as judged by the principal investigator).
- Active malignancy, except basal cell or squamous cell skin cancers.
- Major surgical operation within 30 days prior to screening.
- Seizure disorder (epilepsy).
- Any concurrent illness, other than diabetes, that is not controlled by a stable therapeutic regimen.
- Currently administration of oral or parenteral corticosteroids.
- Use of an investigational drug within 30 days prior to screening.
- Bleeding disorder, treatment with warfarin, or platelet count below 50,000.
Studienplan
Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.
Wie ist die Studie aufgebaut?
Designdetails
- Beobachtungsmodelle: Nur Fall
- Zeitperspektiven: Interessent
Kohorten und Interventionen
Gruppe / Kohorte |
|---|
|
Type 1 diabetic
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Zeitfenster |
|---|---|
|
Difference between very large sensor accuracy errors (≥50% from reference glucose) with the simultaneous use of four sensors vs one sensor.
Zeitfenster: 9-hour collection period, X 2
|
9-hour collection period, X 2
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Zeitfenster |
|---|---|
|
Difference between mean absolute relative difference with the simultaneous use of four sensors vs one sensor.
Zeitfenster: 9-hour glucose level collection, X 2
|
9-hour glucose level collection, X 2
|
Mitarbeiter und Ermittler
Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.
Ermittler
- Hauptermittler: W. Kenneth Ward, MD, Oregon Health and Science University
Publikationen und hilfreiche Links
Die Bereitstellung dieser Publikationen erfolgt freiwillig durch die für die Eingabe von Informationen über die Studie verantwortliche Person. Diese können sich auf alles beziehen, was mit dem Studium zu tun hat.
Allgemeine Veröffentlichungen
- Ward WK, Casey HM, Quinn MJ, Federiuk IF, Wood MD. A fully implantable subcutaneous glucose sensor array: enhanced accuracy from multiple sensing units and a median-based algorithm. Diabetes Technol Ther. 2003;5(6):943-52. doi: 10.1089/152091503322640980.
- Schmidtke DW, Pishko MV, Quinn CP, Heller A. Statistics for critical clinical decision making based on readings of pairs of implanted sensors. Anal Chem. 1996 Sep 1;68(17):2845-9. doi: 10.1021/ac9602027.
- Castle JR, Engle JM, El Youssef J, Massoud RG, Yuen KC, Kagan R, Ward WK. Novel use of glucagon in a closed-loop system for prevention of hypoglycemia in type 1 diabetes. Diabetes Care. 2010 Jun;33(6):1282-7. doi: 10.2337/dc09-2254. Epub 2010 Mar 23.
Studienaufzeichnungsdaten
Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.
Haupttermine studieren
Studienbeginn
1. Juli 2010
Primärer Abschluss (Tatsächlich)
1. Januar 2011
Studienabschluss (Tatsächlich)
1. Januar 2011
Studienanmeldedaten
Zuerst eingereicht
6. November 2013
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
15. September 2014
Zuerst gepostet (Schätzen)
16. September 2014
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Schätzen)
16. September 2014
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
15. September 2014
Zuletzt verifiziert
1. September 2014
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- 11619 (DAIDS ES)
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .