- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT02814123
Effect of Basal-Bolus Closed-Loop Co-Administration of Insulin and Pramlintide on Improving the Glycemic Control in Type 1 Diabetes
A Randomized, Three-way, Crossover Study to Assess the Efficacy of Fast-acting Insulin-plus-pramlintide Closed-loop Co-administration, Regular Insulin-plus-pramlintide Closed-loop Co-administration, and Fast-acting Insulin-alone Closed-loop Infusion in Regulating Glucose Levels Over a 24-hour Period in Adults With Type 1 Diabetes in Inpatient Settings.
The closed-loop delivery system is composed of an insulin pump, a continuous glucose sensor and a dosing algorithm that calculates the insulin dose to infuse based on sensor readings. Pramlintide is a drug and an analog of amylin, a hormone that is co-secreted with insulin in healthy individuals, and is deficient in people with type 1 diabetes. Co-injection of pramlintide with insulin at meal times improves glucose control in type 1 diabetes. Literature data suggests that regular insulin may better match the effect of pramlintide compared to rapid insulin in regulating post-prandial glucose levels.
The purpose of this study is to compare the effectiveness of 3 strategies to control your day-and-night glucose levels:
- rapid insulin-alone closed-loop delivery;
- rapid insulin-plus-pramlintide closed-loop delivery;
- regular insulin-plus-pramlintide closed-loop delivery.
The primary hypotheses are:
- During closed-loop control, the simultaneous basal-bolus infusion of pramlintide and fast-acting insulin improves glucose control compared to fast-acting insulin-alone infusion.
- During closed-loop control, the simultaneous basal-bolus infusion of pramlintide and regular insulin improves glucose control compared to fast-acting insulin-alone infusion.
Studienübersicht
Status
Bedingungen
Intervention / Behandlung
Detaillierte Beschreibung
The closed-loop delivery system is composed of an insulin pump, a continuous glucose sensor and a dosing algorithm that calculates the insulin dose to infuse based on sensor readings. Pramlintide is a drug and an analog of amylin, a hormone that is co-secreted with insulin in healthy individuals, and is deficient in people with type 1 diabetes. Co-injection of pramlintide with insulin at meal times improves glucose control in type 1 diabetes.
Literature data suggests that the pharmacodynamics of regular insulin may better match the effect of pramlintide compared to the pharmacodynamics of fast-acting insulin. Moreover, the cost of regular insulin is significantly lower than fast-acting insulin. Therefore, if a similar (or better) glucose profile can be achieved with regular insulin-plus-pramlintide compared to fast-acting insulin-plus-pramlintide, then a co-formulation employing regular insulin should be prioritized.
Therefore, in this protocol, we aim to assess the effect of the simultaneous, closed-loop, basal-bolus infusion of pramlintide with insulin at a fixed ratio in controlling glucose levels. In the first experimental arm, we propose to infuse pramlintide with fast-acting insulin. In the second experimental arm, pramlintide will be infused with regular insulin. The control arm will be fast-acting insulin-alone closed-loop system.
The aim of the study is to assess the efficacy of the simultaneous, closed-loop, basal-bolus infusion of pramlintide with fast-acting insulin at a fixed ratio and pramlintide with regular insulin at a fixed ratio in controlling glucose levels compared to fast-acting insulin-alone closed-loop infusion.
The investigators aim to conduct a randomized, three-way, crossover trial to compare the efficacy of 1) fast-acting insulin-plus-pramlintide closed-loop delivery, 2) regular insulin-plus-pramlintide closed-loop delivery, and 3) fast-acting insulin-alone closed-loop delivery in regulating glucose levels over a period of 24 hours in a study on adults in inpatient settings. Insulin (fast-acting and regular) and pramlintide are given with fixed ratio (6 µg of pramlintide for each unit of insulin).
Before each 24-hour intervention visit, the participant's insulin therapy (basal rates and insulin-to-carbohydrate ratios) will be optimized for a minimum of 10 days, with a target of 14 days.
There will be a wash-out period of 0 to 42 days between the three intervention arms (termination of 24-hr intervention and start of next optimization period).
The primary hypotheses are:
- During closed-loop control, the simultaneous basal-bolus infusion of pramlintide and fast-acting insulin improves glucose control compared to fast-acting insulin-alone infusion.
- During closed-loop control, the simultaneous basal-bolus infusion of pramlintide and regular insulin improves glucose control compared to fast-acting insulin-alone infusion.
Studientyp
Einschreibung (Tatsächlich)
Phase
- Phase 2
Kontakte und Standorte
Studienorte
-
-
Quebec
-
Montréal, Quebec, Kanada
- McGill University Health Centre
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- Males and females ≥ 18 years of age.
- Clinical diagnosis of type 1 diabetes for at least 12 months. (The diagnosis of type 1 diabetes is based on the investigator's judgment; C peptide level and antibody determinations are not needed.)
- The subject will have been on insulin pump therapy for at least 6 months.
- HbA1c ≤ 10%.
Exclusion Criteria:
- Current or ≤ 1 month use of other antihyperglycemic agents (SGLT2, GLP-1, Metformin, Acarbose, etc.…).
- Severe hypoglycemic episode within one month of screening.
- Severe diabetes keto-acidosis episode within one month of screening.
- Planned or ongoing pregnancy.
- Known or suspected allergy to the study drugs.
- Gastroparesis.
- Use of prokinetic drugs that stimulate gastric emptying (domperidone, cisapride, metoclopramide).
- Clinically significant nephropathy, neuropathy or retinopathy as judged by the investigator.
- Recent (< 6 months) acute macrovascular event e.g. acute coronary syndrome or cardiac surgery.
- Current use of glucocorticoid medication.
- Other serious medical illness likely to interfere with study participation or with the ability to complete the trial by the judgment of the investigator.
- Failure to comply with team's recommendations (e.g. not willing to eat meals/snacks, not willing to change pump parameters, etc.).
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Behandlung
- Zuteilung: Zufällig
- Interventionsmodell: Crossover-Aufgabe
- Maskierung: Keine (Offenes Etikett)
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Aktiver Komparator: Rapid Insulin-alone closed-loop delivery
Rapid Insulin will be delivered by subcutaneous infusion.
Interventions: 24-hour inpatient intervention Drug: Rapid acting Insulin (aspart, lispro, glulisine)
|
Subjects will be admitted at the research facility at 7:30.
A cannula will be inserted into an arm or a hand vein for blood sampling purposes.
Each 24-hour intervention visit includes 3 standardized meals (8:00, 12:00, and 17:00), an evening snack (21:00) and an overnight stay.
The glucose level as measured by the real time sensor will be entered manually into the computer every 10 minutes.
The insulin and pramlintide pumps' infusion rates will then be changed manually based on the computer generated recommendation, while still maintaining the ratio.
The computer generated recommendations are based on a predictive algorithm.
|
|
Experimental: Rapid Insulin-plus-pramlintide closed-loop delivery
Rapid insulin and pramlintide will be delivered by subcutaneous infusion using a fixed ratio (6 µg pramlintide/unit insulin). Interventions: 24-hour inpatient intervention Drug: Rapid acting Insulin (aspart, lispro, glulisine) Drug: Pramlintide |
Subjects will be admitted at the research facility at 7:30.
A cannula will be inserted into an arm or a hand vein for blood sampling purposes.
Each 24-hour intervention visit includes 3 standardized meals (8:00, 12:00, and 17:00), an evening snack (21:00) and an overnight stay.
The glucose level as measured by the real time sensor will be entered manually into the computer every 10 minutes.
The insulin and pramlintide pumps' infusion rates will then be changed manually based on the computer generated recommendation, while still maintaining the ratio.
The computer generated recommendations are based on a predictive algorithm.
|
|
Experimental: Regular Insulin-plus-pramlintide closed-loop delivery
Regular insulin and pramlintide will be delivered by subcutaneous infusion using a fixed ratio (6 µg pramlintide/unit insulin). Interventions: 24-hour inpatient intervention Drug: Regular Insulin (humulin R) Drug: Pramlintide |
Subjects will be admitted at the research facility at 7:30.
A cannula will be inserted into an arm or a hand vein for blood sampling purposes.
Each 24-hour intervention visit includes 3 standardized meals (8:00, 12:00, and 17:00), an evening snack (21:00) and an overnight stay.
The glucose level as measured by the real time sensor will be entered manually into the computer every 10 minutes.
The insulin and pramlintide pumps' infusion rates will then be changed manually based on the computer generated recommendation, while still maintaining the ratio.
The computer generated recommendations are based on a predictive algorithm.
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Zeitfenster |
|---|---|
|
Percentage of time of plasma glucose levels spent in target range. Target range is defined to be between 3.9 and 10.0 mmol/L of fast-acting insulin-plus-pramlintide closed-loop delivery vs. fast-acting insulin-alone closed-loop delivery.
Zeitfenster: Up to 24 hours
|
Up to 24 hours
|
|
Percentage of time of plasma glucose levels spent in target range. Target range is defined to be between 3.9 and 10.0 mmol/L of regular insulin-plus-pramlintide closed-loop delivery vs. fast-acting insulin-alone closed-loop delivery.
Zeitfenster: Up to 24 hours
|
Up to 24 hours
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Zeitfenster |
|---|---|
|
Percentage of time of plasma glucose levels spent in target range, comparing fast-acting insulin-plus-pramlintide closed-loop delivery vs. regular insulin-plus-pramlintide closed-loop delivery.
Zeitfenster: Up to 24 hours
|
Up to 24 hours
|
|
Percentage of time (8:00-8:00) of plasma glucose levels spent: a. 3.9-7.8 mmol/L; b. 3.9-10 mmol/L; c. <3.9 mmol/L; d. <3.3 mmol/L; e. <2.8 mmol/L; f. >7.8 mmol/L; g. >10 mmol/L; h. >13.9 mmol/L; i. >16.7 mmol/L
Zeitfenster: Up to 24 hours
|
Up to 24 hours
|
|
Percentage of overnight time (23:00-8:00) of plasma glucose levels: a. 3.9-7.8 mmol/L; b. 3.9-10 mmol/L; c. <3.9 mmol/L; d. <3.3 mmol/L; e. <2.8 mmol/L; f. >7.8 mmol/L; g. >10 mmol/L; h. >13.9 mmol/L; i. >16.7 mmol/L
Zeitfenster: Up to 24 hours
|
Up to 24 hours
|
|
Standard deviation of glucose levels as a measure of glucose variability.
Zeitfenster: Up to 24 hours
|
Up to 24 hours
|
|
Total insulin delivery.
Zeitfenster: Up to 24 hours
|
Up to 24 hours
|
|
Total pramlintide delivery.
Zeitfenster: Up to 24 hours
|
Up to 24 hours
|
|
Mean plasma glucose level during: a. the overall study period; b. overnight period.
Zeitfenster: Up to 24 hours
|
Up to 24 hours
|
|
Mean plasma insulin concentration.
Zeitfenster: Up to 24 hours
|
Up to 24 hours
|
|
Mean plasma glucagon concentration.
Zeitfenster: Up to 24 hours
|
Up to 24 hours
|
|
Mean plasma amylin concentration.
Zeitfenster: Up to 24 hours
|
Up to 24 hours
|
|
Number of subjects experiencing hypoglycemia requiring oral treatment during: a. the overall study period; b. the night.
Zeitfenster: Up to 24 hours
|
Up to 24 hours
|
|
Gastrointestinal symptoms during the treatment optimization (i.e., the minimum 10 days prior to the 24-hour closed-loop visits) and during the 24-hour closed-loop visits.
Zeitfenster: Up to 24 hours
|
Up to 24 hours
|
Mitarbeiter und Ermittler
Sponsor
Mitarbeiter
Ermittler
- Hauptermittler: Ahmad Haidar, McGill University
- Hauptermittler: Laurent Legault, McGill University Health Centre/Research Institute of the McGill University Health Centre
Publikationen und hilfreiche Links
Allgemeine Veröffentlichungen
- Haidar A, Tsoukas MA, Bernier-Twardy S, Yale JF, Rutkowski J, Bossy A, Pytka E, El Fathi A, Strauss N, Legault L. A Novel Dual-Hormone Insulin-and-Pramlintide Artificial Pancreas for Type 1 Diabetes: A Randomized Controlled Crossover Trial. Diabetes Care. 2020 Mar;43(3):597-606. doi: 10.2337/dc19-1922. Epub 2020 Jan 23.
- Tsoukas M, Rutkowski J, El-Fathi A, Yale JF, Bernier-Twardy S, Bossy A, Pytka E, Legault L, Haidar A. Accuracy of FreeStyle Libre in Adults with Type 1 Diabetes: The Effect of Sensor Age. Diabetes Technol Ther. 2020 Mar;22(3):203-207. doi: 10.1089/dia.2019.0262. Epub 2020 Jan 23.
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Tatsächlich)
Studienabschluss (Tatsächlich)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Schätzen)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- MAP-1
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .