- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT07897331
Early Heart Rate Variability and Sleep and Quality of Recovery After Cesarean Delivery (Otonom-CS)
Association of Early Postoperative Heart Rate Variability and Sleep Parameters With Quality of Recovery After Cesarean Delivery: A Prospective Observational Cohort Study
This prospective single-center observational cohort study investigates whether objectively measured early postoperative heart rate variability (HRV) and sleep parameters are associated with patient-reported quality of recovery after cesarean delivery. Women who deliver by cesarean section wear a consumer wrist device (Garmin Vívosmart 5) on the non-dominant wrist during the in-hospital period (first 48 hours). HRV metrics (e.g., RMSSD), continuous heart rate, and sleep are derived from raw beat-to-beat intervals via the Fitrockr platform. Quality of recovery is measured with the validated Turkish Obstetric Quality-of-Recovery score (ObsQoR-11T) at 24 and 48 hours, and subjective sleep with the Richards-Campbell Sleep Questionnaire (RCSQ). The primary hypothesis is that higher early HRV (particularly RMSSD) and better sleep are associated with higher ObsQoR-11T at postoperative day 1 (24 hours). The wearable is used for research purposes only and does not inform any clinical decision; routine care proceeds independently of the study.
Studienübersicht
Status
Intervention / Behandlung
Detaillierte Beschreibung
Background: Cesarean section is among the most common surgical procedures, and objective assessment of postpartum recovery may help improve quality of care. Wearable-derived autonomic (HRV) and sleep measures are candidate objective correlates of recovery but have not been characterized in the early in-hospital cesarean period.
Objectives / Hypotheses:
- H1: Higher early HRV (e.g., RMSSD, HF power) is associated with better ObsQoR-11T score.
- H2: Shorter / more fragmented sleep (sleep duration, efficiency, number of awakenings) is associated with lower ObsQoR-11T score.
Procedures: Consenting women receive a Garmin Vívosmart 5 on the non-dominant wrist immediately postoperatively; the device remains in hospital only (~48 hours) and is disinfected/recharged between patients. Raw beat-to-beat intervals and computed HRV metrics (RMSSD, SDNN, pNN50, LF, HF, LF/HF, SD1/SD2), continuous heart rate, sleep, and minute-level device-derived stress scores and Body Battery are obtained from the Fitrockr platform. Patient-reported outcomes (ObsQoR-11T, RCSQ, numeric rating scale [NRS] pain) and clinical/demographic data are collected via a case report form at 24 and 48 hours.
HRV analysis windows and signal-quality criteria: nocturnal 5-minute stable segments at fixed hours; beats deviating >20% from neighboring intervals are corrected/removed; a segment is analyzable if the corrected/removed beat proportion is ≤5%; the primary window (first 24 hours) requires at least one valid nocturnal segment and ≥80% device wear time within the window.
Statistics: The primary analysis is the association between early (first 24 hours) ln RMSSD and ObsQoR-11T at 24 hours, using Pearson or Spearman correlation according to distribution, with adjustment for age, body mass index, and anesthesia type. The single pre-specified primary test is reported without multiplicity correction; secondary/exploratory analyses apply Benjamini-Hochberg false discovery rate control (q<0.05). Missing data: complete-case for the primary analysis, with multiple-imputation sensitivity analysis. Device-derived stress and Body Battery outcomes are secondary, exploratory measures; because both are derived from heart rate variability, they are not independent of the primary exposure (ln RMSSD) and will be reported descriptively and in exploratory correlation analyses. The proportion of valid minutes will be reported for each participant.
Studientyp
Einschreibung (Geschätzt)
Kontakte und Standorte
Studienkontakt
- Name: Egehan Bilen, MD
- Telefonnummer: +90 539 342 28 46
- E-Mail: egehanbilen@gmail.com
Studienorte
-
-
-
Izmir, Türkei (türkiye), 35390
- Rekrutierung
- Buca Seyfi Demirsoy Training and Research Hospital, Department of Obstetrics and Gynecology
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Probenahmeverfahren
Studienpopulation
Adult women delivering by cesarean section at a single tertiary obstetrics and gynecology clinic.
Beschreibung
Inclusion Criteria:
- Women aged 18 years or older who delivered by cesarean section
- Provided written informed consent
- Clinically able to wear the wrist device throughout the first 48 postoperative hours
Exclusion Criteria:
- Known significant cardiac arrhythmia (e.g., atrial fibrillation) or a permanent pacemaker (invalidates HRV analysis)
- Severe maternal complication requiring intensive care
- Skin or limb condition precluding device placement
- Inability to provide informed consent or to communicate
(Conditions or medications that may substantially affect HRV are recorded and relevant cases excluded as needed.)
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Beobachtungsmodelle: COHORT
- Zeitperspektiven: PROSPECTIVE
Kohorten und Interventionen
Gruppe / Kohorte |
Intervention / Behandlung |
|---|---|
|
Women after cesarean delivery
Adult women who delivered by cesarean section, monitored with a wrist-worn wearable (Garmin Vívosmart 5) for the first 48 postoperative hours. |
Objective HRV, heart rate and sleep metrics derived from a consumer wrist wearable (Garmin Vivosmart 5) via the Fitrockr platform during the first 48 postoperative hours. Measurement only; no clinical intervention is assigned and device data do not inform clinical care. |
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Correlation between early heart rate variability (ln RMSSD) and quality of recovery (ObsQoR-11T)
Zeitfenster: First 24 hours postpartum
|
Correlation (Pearson or Spearman, per distribution) between early postoperative HRV (natural log of RMSSD over the first 24 hours) and the ObsQoR-11T total score (range 0-110; higher = better recovery) at 24 hours postpartum. |
First 24 hours postpartum
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
ObsQoR-11T total score
Zeitfenster: 24 and 48 hours postpartum
|
Obstetric Quality of Recovery score, validated Turkish version (ObsQoR-11T); 11 items, total range 0-110 (higher = better recovery). |
24 and 48 hours postpartum
|
|
Subjective sleep quality (Richards-Campbell Sleep Questionnaire, RCSQ)
Zeitfenster: 24 and 48 hours postpartum
|
RCSQ total score, calculated as the mean of the first 5 items (range 0-100; higher = better sleep). |
24 and 48 hours postpartum
|
|
Standard deviation of NN intervals (SDNN)
Zeitfenster: First 48 hours after cesarean delivery
|
Time-domain heart rate variability computed from raw beat-to-beat intervals recorded by a wrist-worn wearable (Garmin Vivosmart 5) and processed on the Fitrockr platform. Reported in milliseconds from analyzable nocturnal 5-minute segments. |
First 48 hours after cesarean delivery
|
|
Proportion of successive NN intervals differing by more than 50 ms (pNN50)
Zeitfenster: First 48 hours after cesarean delivery
|
Time-domain heart rate variability computed from raw beat-to-beat intervals recorded by a wrist-worn wearable (Garmin Vivosmart 5) and processed on the Fitrockr platform. Reported as a percentage of successive interval pairs from analyzable nocturnal 5-minute segments. |
First 48 hours after cesarean delivery
|
|
Low-frequency power of heart rate variability (LF)
Zeitfenster: First 48 hours after cesarean delivery
|
Frequency-domain heart rate variability (0.04-0.15 Hz) computed from raw beat-to-beat intervals recorded by a wrist-worn wearable (Garmin Vivosmart 5) and processed on the Fitrockr platform. Reported as absolute power in squared milliseconds from analyzable nocturnal 5-minute segments. |
First 48 hours after cesarean delivery
|
|
High-frequency power of heart rate variability (HF)
Zeitfenster: First 48 hours after cesarean delivery
|
Frequency-domain heart rate variability (0.15-0.40 Hz) computed from raw beat-to-beat intervals recorded by a wrist-worn wearable (Garmin Vivosmart 5) and processed on the Fitrockr platform. Reported as absolute power in squared milliseconds from analyzable nocturnal 5-minute segments. |
First 48 hours after cesarean delivery
|
|
Ratio of low-frequency to high-frequency power (LF/HF)
Zeitfenster: First 48 hours after cesarean delivery
|
Ratio of absolute low-frequency to high-frequency heart rate variability power, computed from raw beat-to-beat intervals recorded by a wrist-worn wearable (Garmin Vivosmart 5) and processed on the Fitrockr platform. Reported as a unitless ratio from analyzable nocturnal 5-minute segments. |
First 48 hours after cesarean delivery
|
|
Ratio of Poincare plot descriptors SD1 to SD2
Zeitfenster: First 48 hours after cesarean delivery
|
Non-linear heart rate variability index computed from raw beat-to-beat intervals recorded by a wrist-worn wearable (Garmin Vivosmart 5) and processed on the Fitrockr platform. Reported as a unitless ratio from analyzable nocturnal 5-minute segments. |
First 48 hours after cesarean delivery
|
|
Natural log of RMSSD at fixed postoperative time windows
Zeitfenster: 12, 24, 36 and 48 hours after cesarean delivery
|
Natural logarithm of the root mean square of successive beat-to-beat interval differences, computed from raw beat-to-beat intervals recorded by a wrist-worn wearable (Garmin Vivosmart 5) and processed on the Fitrockr platform, at fixed postoperative windows. Reported as ln(ms). |
12, 24, 36 and 48 hours after cesarean delivery
|
|
Mean heart rate at fixed postoperative time windows
Zeitfenster: 12, 24, 36 and 48 hours after cesarean delivery
|
Mean heart rate derived from the wrist-worn wearable (Garmin Vivosmart 5) via the Fitrockr platform at fixed postoperative windows, reported in beats per minute. |
12, 24, 36 and 48 hours after cesarean delivery
|
|
Total sleep time measured by the wearable device
Zeitfenster: First 48 hours after cesarean delivery
|
Total sleep time derived from the wrist-worn wearable (Garmin Vivosmart 5) via the Fitrockr platform, reported in minutes. |
First 48 hours after cesarean delivery
|
|
Sleep efficiency measured by the wearable device
Zeitfenster: First 48 hours after cesarean delivery
|
Total sleep time divided by time in bed, derived from the wrist-worn wearable (Garmin Vivosmart 5) via the Fitrockr platform and reported as a percentage. |
First 48 hours after cesarean delivery
|
|
Number of awakenings measured by the wearable device
Zeitfenster: First 48 hours after cesarean delivery
|
Count of awakenings during the sleep period, derived from the wrist-worn wearable (Garmin Vivosmart 5) via the Fitrockr platform. |
First 48 hours after cesarean delivery
|
|
Agreement between objective (device) and subjective (RCSQ) sleep
Zeitfenster: First 48 hours postpartum
|
Correlation/agreement between wearable-derived sleep parameters and the RCSQ score. |
First 48 hours postpartum
|
|
Pain at rest on a numeric rating scale
Zeitfenster: 24 and 48 hours after cesarean delivery
|
Patient-reported pain intensity at rest on a numeric rating scale from 0 to 10, where 0 is no pain and 10 is the worst imaginable pain. |
24 and 48 hours after cesarean delivery
|
|
Pain on movement on a numeric rating scale
Zeitfenster: 24 and 48 hours after cesarean delivery
|
Patient-reported pain intensity on movement on a numeric rating scale from 0 to 10, where 0 is no pain and 10 is the worst imaginable pain. |
24 and 48 hours after cesarean delivery
|
|
Total opioid consumption in oral morphine milligram equivalents
Zeitfenster: First 48 hours after cesarean delivery
|
Cumulative opioid dose administered after cesarean delivery, converted to oral morphine milligram equivalents and recorded from the medication chart. |
First 48 hours after cesarean delivery
|
|
Change in ObsQoR-11T from 24 to 48 hours
Zeitfenster: 24 to 48 hours postpartum
|
Difference in ObsQoR-11T total score (range 0-110; higher = better recovery) between 24 and 48 hours postpartum, and its association with early HRV and sleep. |
24 to 48 hours postpartum
|
|
Mean device-derived stress score
Zeitfenster: First 48 hours after cesarean delivery
|
Mean of minute-level stress scores recorded by the wrist-worn wearable (Garmin Vivosmart 5; proprietary 0-100 scale derived from heart rate variability, higher values indicate greater physiological stress) and exported via the Fitrockr platform, averaged over all valid minutes. Reported as score units on a 0-100 scale. |
First 48 hours after cesarean delivery
|
|
Proportion of valid wear time in the rest stress state
Zeitfenster: First 48 hours after cesarean delivery
|
Percentage of valid minutes in which the wrist-worn wearable (Garmin Vivosmart 5) recorded a stress score of 0-25 (rest state on the device's proprietary 0-100 scale), exported via the Fitrockr platform. |
First 48 hours after cesarean delivery
|
|
Number of stress episodes per 24 hours
Zeitfenster: First 48 hours after cesarean delivery
|
Number of episodes of at least 3 consecutive minutes with a device-derived stress score above 50 (medium or high stress on the Garmin Vivosmart 5 proprietary 0-100 scale), exported via the Fitrockr platform and normalized to episodes per 24 hours of valid wear time. |
First 48 hours after cesarean delivery
|
|
Median stress recovery time after stress episodes
Zeitfenster: First 48 hours after cesarean delivery
|
Median time in minutes from the end of each stress episode (at least 3 consecutive minutes with a device-derived stress score above 50) to the first subsequent minute with a stress score of 25 or below (rest state), computed from minute-level Garmin Vivosmart 5 stress scores exported via the Fitrockr platform. |
First 48 hours after cesarean delivery
|
|
Overnight Body Battery charge
Zeitfenster: First and second postoperative nights (within 48 hours after cesarean delivery)
|
Change in the device-derived Body Battery energy score (Garmin Vivosmart 5; proprietary 0-100 scale estimated from heart rate variability, stress, sleep and activity) from the start to the end of the main nocturnal sleep period detected by the device, exported via the Fitrockr platform. Reported as score units on a 0-100 scale; positive values indicate recharge. |
First and second postoperative nights (within 48 hours after cesarean delivery)
|
Mitarbeiter und Ermittler
Publikationen und hilfreiche Links
Allgemeine Veröffentlichungen
- Ciechanowicz S, Setty T, Robson E, Sathasivam C, Chazapis M, Dick J, Carvalho B, Sultan P. Development and evaluation of an obstetric quality-of-recovery score (ObsQoR-11) after elective Caesarean delivery. Br J Anaesth. 2019 Jan;122(1):69-78. doi: 10.1016/j.bja.2018.06.011. Epub 2018 Jul 31.
- Richards KC, O'Sullivan PS, Phillips RL. Measurement of sleep in critically ill patients. J Nurs Meas. 2000 Fall-Winter;8(2):131-44.
- Miller DJ, Sargent C, Roach GD. A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults. Sensors (Basel). 2022 Aug 22;22(16):6317. doi: 10.3390/s22166317.
- Ozkan G, Kara U, Ince ME, Ozdemir O, Ulubay M, Senkal S. Validation of the Turkish version of the Obstetric Quality-of-Recovery score 11 (ObsQoR-11T) after cesarean delivery. Health Qual Life Outcomes. 2022 Nov 28;20(1):155. doi: 10.1186/s12955-022-02073-y.
- Karaman Ozlu Z, Ozer N. Richard-Campbell Sleep Questionnaire validity and reliability study [Richard-Campbell Uyku Olcegi Gecerlilik ve Guvenilirlik Calismasi]. J Turk Sleep Med. 2015;2(2):29-32. doi:10.4274/jtsm.02.008
- Georgiou K, Larentzakis AV, Khamis NN, Alsuhaibani GI, Alaska YA, Giallafos EJ. Can Wearable Devices Accurately Measure Heart Rate Variability? A Systematic Review. Folia Med (Plovdiv). 2018 Mar 1;60(1):7-20. doi: 10.2478/folmed-2018-0012.
- Dial MB, Hollander ME, Vatne EA, Emerson AM, Edwards NA, Hagen JA. Validation of nocturnal resting heart rate and heart rate variability in consumer wearables. Physiol Rep. 2025 Aug;13(16):e70527. doi: 10.14814/phy2.70527.
- Schyvens AM, Peters B, Van Oost NC, Aerts JM, Masci F, Neven A, Dirix H, Wets G, Ross V, Verbraecken J. A performance validation of six commercial wrist-worn wearable sleep-tracking devices for sleep stage scoring compared to polysomnography. Sleep Adv. 2025 Mar 22;6(2):zpaf021. doi: 10.1093/sleepadvances/zpaf021. eCollection 2025 Apr.
- Gielen J, Van Oost CN, Debard G, Sels R, De Witte NAJ, Colman T, Bonroy B, Aerts JM. Accuracy of Optical Heart Rate Measurements for 10 Commercial Wearables in Different Climate Conditions and Activities: Instrument Validation Study. JMIR Form Res. 2026 Feb 17;10:e85186. doi: 10.2196/85186.
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Geschätzt)
Studienabschluss (Geschätzt)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- Otonom-CS
- 2026/09-130 (Andere Kennung: Buca Seyfi Demirsoy Training and Research Hospital Non-Interventional Research Ethics Committee)
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Beschreibung des IPD-Plans
De-identified individual participant data (heart rate variability, sleep and outcome variables) underlying the reported results may be made available from the corresponding author on reasonable request.
IPD-Sharing-Zeitrahmen
Beginning 6 months and ending 5 years after publication of the main results.
IPD-Sharing-Zugriffskriterien
Requests from qualified researchers with a methodologically sound proposal, submitted to the corresponding author. A data access agreement is required, and sharing is subject to approval by the principal investigator and compliance with applicable data protection law.
Art der unterstützenden IPD-Freigabeinformationen
- STUDIENPROTOKOLL
- SAFT
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .