- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT07913412
High-precision Radiosurgery Followed by Minimally Invasive Surgical Approach in Patients With High-prominence Uveal Melanoma: Modern Radiation Techniques and Outcomes (PRIME)
High-precision Radiosurgery Followed by Minimally Invasive Surgical Approach in Patients With High-prominence Uveal Melanoma: Modern Radiation Techniques and Outcomes; PRIME: P: Precision R: Radiosurgery I: Intervention M: Minimal Invasive Surgical Approach E: EYESIGHT
High-precision radiosurgery followed by minimally invasive surgical approach in patients with high-prominence uveal melanomas: modern radiation techniques and outcomes. Evaluation of outcome regarding multiparametric parameters and co-factors
Studienübersicht
Status
Detaillierte Beschreibung
The aim here is to prospectively evaluate modern technical standards. The aim of this study is to assess the influence of the updated basic diagnostics and high-resolution diagnostics for radiation planning and the new technical therapy standards (therapy options in application: volume modulated rapid arc technique (VMAT) / online arc technique (VMAT) / online onboard image-guidance (IGRT), by means of the newly established Clinic for Radiation Therapy 2019-2021) depending on known prognostic parameters for quality assurance of the long-term outcome (overall survival, local tumor control). This will lay the basis for standardizing treatment parameters as far as possible, but also to introduce improvements in the treatment of future patients.
Scientific background (state of research (with literature references) and
Derivation of the research question (rationale)):
The eye can be affected by several neoplastic processes, which can lead either primarily or secondary to systemic metastasis. The most common primary tumors of the eye include conjunctival melanoma and uveal melanoma. Metastases from systemic malignant diseases, particularly of the breast and lungs, can also affect the eye.
A combination of ophthalmologic examination, MRI and additional tests and cytologic/histopathologic evaluation leads to an accurate diagnosis.
Depending on the tumor manifestation, treatment consists of a multimodal concept. In the case of uveal melanomas and the aim of preserving the globe and and visual acuity preservation, radiotherapy is one of the most important treatment modalities that can be applied.
In the last 20 years, radiotherapy has developed rapidly away from two-dimensional modulated, three-dimensional techniques. But here too the high level of technical diversity in radiotherapy and ever newer technical innovations, there is a broad spectrum of radiotherapy. Standard therapy can be performed using modern devices, the high-precision stereotactic linear accelerators (irradiation devices), can be safely further optimized. This is to be tested in the Department of Radiotherapy.
Studientyp
Einschreibung (Geschätzt)
Kontakte und Standorte
Studienkontakt
- Name: Maja Guberina, PD MD
- Telefonnummer: 0201 723 83121
- E-Mail: maja.guberina@uk-essen.de
Studienorte
-
-
-
Essen, Deutschland
- Rekrutierung
- University Hospital Essen
-
Kontakt:
- Maja Guberina
- Telefonnummer: +4920127232321
- E-Mail: maja.guberina@uk-essen.de
-
Essen, Deutschland, 45147
- Rekrutierung
- Maja Guberina
-
Kontakt:
- Maja W Strahlentherapie
- Telefonnummer: +492017232321
- E-Mail: maja.guberina@uk-essen.de
-
-
Germany / NRW
-
Essen, Germany / NRW, Deutschland, 45147
- Rekrutierung
- Department for Radiotherapy, University Hospital Essen, National Center for Tumor Diseases (NCT) West
-
Kontakt:
- Maja Guberina, PD Dr. med. (MD), specialist
- Telefonnummer: +492017232321
- E-Mail: maja.guberina@uk-essen.de
-
Kontakt:
- Ina Grübel
-
Hauptermittler:
- Maja Guberina, PD Dr. med. (MD)
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Probenahmeverfahren
Studienpopulation
Inclusion Criteria:
- Resectability, high-prominent and high risk uveal melanoma
Exclusion Criteria:
- EOE
- lux defect (If a medical report notes a "lux defect" alongside this, it refers to a deficit in light perception (from the Latin lux for light). It means the eye's ability to sense light, darkness, or light direction is impaired)
Beschreibung
Inclusion Criteria:
- Functional Resectability,
- Technical Resectability
- high-prominent uveal melanoma
Exclusion Criteria:
- EOE
- At least in part remaining eye function that can be saved
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Beobachtungsmodelle: COHORT
- Zeitperspektiven: PROSPECTIVE
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Local control
Zeitfenster: At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
Local control |
At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
|
Function: Visual acuity:
Zeitfenster: At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
Visual function assessed separately for each eye. Visual acuity: decimal scale,range 2,0 - 0,01: decimal acuity scale |
At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
|
Quality of Life, ophthalmic cancer-specific quality of life
Zeitfenster: At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
Quality of Life, ophthalmic cancer-specific quality of life 1) EORTC QLQ-OPT30 (ophthalmic cancer-specific quality of life): Scores range from 0-100; higher scores indicate greater visual impairment, ocular symptoms, and functional difficulties. |
At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
|
Progression Free Survival
Zeitfenster: At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
Progression Free Survival |
At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
|
Overall Survival
Zeitfenster: At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
Overall Survival |
At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
|
Function: Visual acuity:
Zeitfenster: At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
Visual function assessed separately for each eye. Visual acuity: decimal scale,range 2,0 - 0,01: decimal acuity scale; furthermore, 1.Count-fingers, 2.hand-motion and 3.light-perception categories are recorded separately when acuity cannot be quantified: for each item: value yes / no |
At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
|
Function: Visual field
Zeitfenster: At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
Visual field: Automated perimetry, Visual Field Index (VFI, %): 0 % - 100%, |
At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
|
Quality of Life general quality of life
Zeitfenster: At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
EORTC QLQ-C30 (general quality of life): Scores range from 0-100; A) higher scores indicate better functioning/global quality of life B) symptom scores: indicate greater symptom burden on symptom scales. |
At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
|
Function: Retinal Nerve Fiber Layer
Zeitfenster: At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
Optical coherence tomography (OCT): Peripapillary retinal nerve fiber layer (RNFL) thickness, measured in µm and classified in percentiles (regarding normal values) |
At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
|
Cornea
Zeitfenster: At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
corneal outcome: thickness measured in µm |
At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
|
Cornea
Zeitfenster: At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
Corneal outcome modified Stocker's classification: category 0 No damage no injury category 1 corneal guttae without epithelial or stromal edema. category 2 corneal guttae with epithelial or stromal edema. category 3 corneal edema associated with scar formation. category 4 corneal opacification with neovascularization, modified Stocker's classification |
At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
|
Corneal overall outcome classification
Zeitfenster: At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
category 0 No corneal-ulcus category 1 Irregular punctate epithelial defects category 2 Non-healing epithelial defects / persistent epithelial defect (PED) category 3 Ulcer perforation |
At 3 months, every 6 months up to 24 months, and annually thereafter up to 60 -120 months.
|
Mitarbeiter und Ermittler
Sponsor
Publikationen und hilfreiche Links
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Geschätzt)
Studienabschluss (Geschätzt)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
- Neubildungen nach Standort
- Neubildungen
- Neubildungen nach histologischem Typ
- Augenkrankheiten
- Neuroektodermale Tumoren
- Neoplasmen, Keimzelle und Embryonal
- Neubildungen, Nervengewebe
- Neuroendokrine Tumoren
- Nävi und Melanome
- Neubildungen des Auges
- Aderhauterkrankungen
- Melanom
- Aderhautneoplasmen
- Uveales Melanom
Andere Studien-ID-Nummern
- 21-10377-BO
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Beschreibung des IPD-Plans
dependent on the project
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .