Correlation of Clinical Response to "Scratch Collapse Test" and Findings of Electromyoneurography
The goal of this observational study is to correlate findings of scratch collapse test (SCT) and electromyoneurography (EMNG) findings in patients with compressive neuropathies in upper extremities. The main goal is to determine and quantify the correlation between digitally measured force drop in SCT and electrophysiological abnormalities on EMNG in patients with compressive upper extremities syndromes.
Participants will be examined clinically and during that examination SCT will be performed with dynamometer and EMNG testing will be performed.
Studienübersicht
Status
Bedingungen
Intervention / Behandlung
Detaillierte Beschreibung
Main goal of this study is to determine and quantify the correlation between digitally measured force drop in SCT and electrophysiological abnormalities on EMNG in patients with compressive hand syndromes.
The "scratch collapse test" (SCT) is an innovative, rapid and non-invasive clinical test with extremely high specificity for the exact anatomical localization of the compression site.
SCT uses reflex inhibition of the motor response (cutaneous silent period) induced by gently scratching the skin above the compression site, which results in a momentary loss of resistance to shoulder external rotation.
A key drawback of the traditional SCT is the subjectivity of the examiner's manual assessment, as well as the patient's cooperation; consequently, previous studies have often shown variable results regarding the test's sensitivity and specificity, as well as its correlation with objective neurophysiological parameters provided by EMNG (motor and sensory conduction velocities, amplitudes, and latencies).
Electromyoneurography is a neurophysiological diagnostic method combining Nerve Conduction Studies (NCS) and needle Electromyography (EMG) to evaluate the functional integrity of peripheral nerves and skeletal muscles.
In upper extremity compression syndromes EMNG localizes and quantifies the lesion through specific pathophysiological markers. Localized myelin compression reduces saltatory conduction, causing a drop in conduction velocity across the entrapped segment so the EMNG detects a significant drop in signal speed across the specific site of entrapment. The time it takes for an electrical impulse to travel from the stimulation site to the recording electrode increases significantly at the compression point which manifests on the EMNG as a prolongation of the distal latency. Also, reduction of Sensory Nerve Action Potential (SNAP) and Compound Muscle Action Potential (CMAP) amplitudes indicate axonal loss or conduction block. In chronic or severe axonotmesis, target muscles exhibit abnormal spontaneous activity at rest (fibrillations, positive sharp waves) and neurogenic motor unit action potential (MUAP) remodeling on needle EMG.
The primary objective of this prospective study is to determine and quantify the correlation between a digitally measured reduction in force in SCT and electrophysiological abnormalities observed via electromyoneurography (EMNG) in patients with compressive syndromes of the upper extremities.
Participants will be examined clinically and during that examination SCT will be performed with dynamometer and EMNG testing will be performed. Collected data will be statistically analyzed to find correlation between SCT and EMNG for different compressive syndromes of upper extremities.
Studientyp
Einschreibung (Geschätzt)
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Probenahmeverfahren
Studienpopulation
The study will include 100 participants, aged 18 to 65, referred for electromyoneurography (EMNG) due to a clinical suspicion of compression syndromes of the upper extremities.
Beschreibung
Inclusion Criteria:
The study will include 100 participants, aged 18 to 65, referred for electromyoneurography (EMNG) due to a clinical suspicion of compression syndromes of the upper extremities.
Exclusion Criteria:
- neuromuscular disease accompanied by arm weakness; generalized polyneuropathy; local injuries (open wounds, burns, or infection at the stimulation site); recent trauma or surgery (within the last 6 months); cognitive impairment preventing the patient from understanding or following instructions; language barriers; shoulder-related conditions, such as rotator cuff rupture, tendinopathy, or calcific tendinitis
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Beobachtungsmodelle: COHORT
- Zeitperspektiven: PROSPECTIVE
Kohorten und Interventionen
Gruppe / Kohorte |
Intervention / Behandlung |
|---|---|
|
carpal tunnel syndrome
|
Clinical test that uses reflex inhibition of the motor response (cutaneous silent period) induced by light scratching of the skin above the compression site, which results in a momentary loss of resistance to shoulder external rotation. In this study we will use the digital dynamometer to measure force of external shoulder rotation before and after scratching the skin above the compression site. The EMNG procedure for upper extremity compression syndromes consists of a two-step neurophysiological protocol tailored to the specific nerve suspected of entrapment. Surface recording electrodes are attached to the skin over a target muscle. A ground electrode is placed nearby to reduce electrical noise. The examiner uses a handheld stimulator to deliver brief, low-voltage electrical shocks at specific anatomical points along the nerve path. Then a fine, sterile disposable pin electrode is inserted directly into selected muscles inervated by the exact nerve. The collected datas are analyzed.
Andere Namen:
Diagnostic test that uses patches and needles to measure the speed and strength of electrical signals as they travel through a nerve and electrical signals in muscles and motor neurons at rest and during active contraction. |
|
Ulnar tunnel syndrome
|
Clinical test that uses reflex inhibition of the motor response (cutaneous silent period) induced by light scratching of the skin above the compression site, which results in a momentary loss of resistance to shoulder external rotation. In this study we will use the digital dynamometer to measure force of external shoulder rotation before and after scratching the skin above the compression site. The EMNG procedure for upper extremity compression syndromes consists of a two-step neurophysiological protocol tailored to the specific nerve suspected of entrapment. Surface recording electrodes are attached to the skin over a target muscle. A ground electrode is placed nearby to reduce electrical noise. The examiner uses a handheld stimulator to deliver brief, low-voltage electrical shocks at specific anatomical points along the nerve path. Then a fine, sterile disposable pin electrode is inserted directly into selected muscles inervated by the exact nerve. The collected datas are analyzed.
Andere Namen:
Diagnostic test that uses patches and needles to measure the speed and strength of electrical signals as they travel through a nerve and electrical signals in muscles and motor neurons at rest and during active contraction. |
|
Gyon tunnel syndrome
|
Clinical test that uses reflex inhibition of the motor response (cutaneous silent period) induced by light scratching of the skin above the compression site, which results in a momentary loss of resistance to shoulder external rotation. In this study we will use the digital dynamometer to measure force of external shoulder rotation before and after scratching the skin above the compression site. The EMNG procedure for upper extremity compression syndromes consists of a two-step neurophysiological protocol tailored to the specific nerve suspected of entrapment. Surface recording electrodes are attached to the skin over a target muscle. A ground electrode is placed nearby to reduce electrical noise. The examiner uses a handheld stimulator to deliver brief, low-voltage electrical shocks at specific anatomical points along the nerve path. Then a fine, sterile disposable pin electrode is inserted directly into selected muscles inervated by the exact nerve. The collected datas are analyzed.
Andere Namen:
Diagnostic test that uses patches and needles to measure the speed and strength of electrical signals as they travel through a nerve and electrical signals in muscles and motor neurons at rest and during active contraction. |
|
Other upper extremities compressive syndromes
|
Clinical test that uses reflex inhibition of the motor response (cutaneous silent period) induced by light scratching of the skin above the compression site, which results in a momentary loss of resistance to shoulder external rotation. In this study we will use the digital dynamometer to measure force of external shoulder rotation before and after scratching the skin above the compression site. The EMNG procedure for upper extremity compression syndromes consists of a two-step neurophysiological protocol tailored to the specific nerve suspected of entrapment. Surface recording electrodes are attached to the skin over a target muscle. A ground electrode is placed nearby to reduce electrical noise. The examiner uses a handheld stimulator to deliver brief, low-voltage electrical shocks at specific anatomical points along the nerve path. Then a fine, sterile disposable pin electrode is inserted directly into selected muscles inervated by the exact nerve. The collected datas are analyzed.
Andere Namen:
Diagnostic test that uses patches and needles to measure the speed and strength of electrical signals as they travel through a nerve and electrical signals in muscles and motor neurons at rest and during active contraction. |
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Correlation between digitally measured force drop in SCT and electrophysiological abnormalities on EMNG in patients with compressive upper extremities syndromes
Zeitfenster: 12 months
|
The primary objective of this prospective study is to determine and quantify the correlation between a digitally measured reduction in force in SCT and electrophysiological abnormalities observed via EMNG in patients with compressive syndromes of the upper extremities. After the clinical examination, which will test Tinel and the Collapse Scratch test, the patient will be subjected to electrophysiological testing. In the case of peripheral compression of nerves on the upper extremities, EMNG detects a significant drop in signal speed across the specific site of entrapment as well as a prolongation of the distal latency. Also, reduction of Sensory Nerve Action Potential (SNAP) and Compound Muscle Action Potential (CMAP) amplitudes can be found in those patients. In chronic or severe axonotmesis, EMNG detects abnormal spontaneous activity at rest (fibrillations, positive sharp waves) and neurogenic motor unit action potential (MUAP) remodeling on needle stimulation. |
12 months
|
Mitarbeiter und Ermittler
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Geschätzt)
Primärer Abschluss (Geschätzt)
Studienabschluss (Geschätzt)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
- Erkrankungen des Nervensystems
- Wunden und Verletzungen
- Neuromuskuläre Erkrankungen
- Erkrankungen des peripheren Nervensystems
- Mediane Neuropathie
- Mononeuropathien
- Nervenkompressionssyndrome
- Kumulative Traumastörungen
- Verstauchungen und Zerrungen
- Ulnare Neuropathien
- Karpaltunnelsyndrom
- Kompressionssyndrome des Nervus Ulnaris
- Kubitaltunnelsyndrom
- Radiale Neuropathie
- Diagnosetechniken und Verfahren
- Diagnose
- Diagnosetechniken, neurologisch
- Elektrodiagnose
- Myographie
- Nervenleitungsstudien
- Elektromyographie
Andere Studien-ID-Nummern
- 02/2026
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .