First Arrhythmia Collection of Transvenous and Simultaneous Subcutaneous Implantable Defibrillator Data (FACTS)
Tutkimuksen yleiskatsaus
Tila
Yksityiskohtainen kuvaus
The FACTS S-ICD study is a data gathering study that takes place during the implant procedure of a standard T-ICD system. Patients undergoing a routine dual chamber, dual high voltage shocking coil T-ICD or CRT-D insertion or replacement will be connected to an external data recorder via sterile cables. Atrial and ventricular arrhythmias will be induced while multiple ECG views are simultaneously recorded from both intracardiac and surface vectors. These episodes will then be digitized to create the FACTS S-ICD arrhythmia library.
As both dedicated and integrated bipolar sensing configurations are currently utilized in the marketplace, data will be collected using both market available ICD sensing methods.
The FACTS S-ICD study will enroll a sufficient quantity of patients such that a minimum of 50 atrial and 50 ventricular arrhythmic episodes are collected via both dedicated and integrated ICD systems. S-ICD signals will be collected for all recorded episodes.
The T-ICD implant procedure will be completed as per normal hospital practice and no further patient dependent data gathering will be required past the implant surgery and point of surgery arrhythmia inductions.
INCLUSION CRITERIA
- Age 18 or above, or legal age to give consent specific to state and national law.
- Any patient undergoing a clinically indicated initial dual chamber T-ICD or CRT-D implantation. In addition, patients who require replacement of an existing dual chamber T-ICD or CRT-D system will be eligible for enrollment in the study.
- Patient will have a subcutaneous, left pectoral defibrillator implant.
EXCLUSION CRITERIA
- Patients unable or unwilling to provide informed consent.
- Any condition which precludes the subject's ability to comply with the study requirements, including completion of the study.
- Patients in chronic atrial fibrillation who have not been in sinus rhythm within the last six months.
- Enrollment in a concurrent study, without Cameron Health's written approval, that may confound the results of this study.
- Women who are pregnant or who are trying to become pregnant Note: Women of child bearing potential must have a negative pregnancy test within 7 days prior to defibrillator implant.
- Patient requires left sub-muscular or right sided defibrillator implant
Opintotyyppi
Ilmoittautuminen (Todellinen)
Yhteystiedot ja paikat
Opiskelupaikat
-
-
-
Rotterdam, Alankomaat, 3000 CA
- Erasmus Medical Centre
-
-
-
-
Illinois
-
Chicago, Illinois, Yhdysvallat, 60637
- University of Chicago
-
-
South Carolina
-
Charleston, South Carolina, Yhdysvallat, 29425
- Medical University of South Carolina
-
-
Virginia
-
Richmond, Virginia, Yhdysvallat, 23298
- Virginia Commonwealth University
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Näytteenottomenetelmä
Tutkimusväestö
Kuvaus
Inclusion Criteria:
- Age 18 or above, or legal age to give consent specific to state and national law.
- Any patient undergoing a clinically indicated initial dual chamber T-ICD or CRT-D implantation. In addition, patients who require replacement of an existing dual chamber T-ICD or CRT-D system will be eligible for enrollment in the study.
- Patient will have a subcutaneous, left pectoral defibrillator implant
Exclusion Criteria:
- Patients unable or unwilling to provide informed consent.
- Any condition which precludes the subject's ability to comply with the study requirements, including completion of the study.
- Patients in chronic atrial fibrillation who have not been in sinus rhythm within the last six months.
- Enrollment in a concurrent study, without Cameron Health's written approval, that may confound the results of this study.
- Women who are pregnant or who are trying to become pregnant Note: Women of child bearing potential must have a negative pregnancy test within 7 days prior to defibrillator implant.
- Patient requires left sub-muscular or right sided defibrillator implant
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Collection of simultaneous cardiac signals representing S-ICD and ICD sensing vectors
Aikaikkuna: 3 years
|
This study will enroll a sufficient number of patients such that a minimum of 50 atrial and 50 ventricular arrhythmic episodes are collected by dedicated and integrated ICD systems and by the simulated S-ICD system
|
3 years
|
Yhteistyökumppanit ja tutkijat
Sponsori
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus
Ensisijainen valmistuminen (Todellinen)
Opintojen valmistuminen (Todellinen)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Arvio)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- FACTS S-ICD
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .