First Arrhythmia Collection of Transvenous and Simultaneous Subcutaneous Implantable Defibrillator Data (FACTS)
Studieöversikt
Status
Betingelser
Detaljerad beskrivning
The FACTS S-ICD study is a data gathering study that takes place during the implant procedure of a standard T-ICD system. Patients undergoing a routine dual chamber, dual high voltage shocking coil T-ICD or CRT-D insertion or replacement will be connected to an external data recorder via sterile cables. Atrial and ventricular arrhythmias will be induced while multiple ECG views are simultaneously recorded from both intracardiac and surface vectors. These episodes will then be digitized to create the FACTS S-ICD arrhythmia library.
As both dedicated and integrated bipolar sensing configurations are currently utilized in the marketplace, data will be collected using both market available ICD sensing methods.
The FACTS S-ICD study will enroll a sufficient quantity of patients such that a minimum of 50 atrial and 50 ventricular arrhythmic episodes are collected via both dedicated and integrated ICD systems. S-ICD signals will be collected for all recorded episodes.
The T-ICD implant procedure will be completed as per normal hospital practice and no further patient dependent data gathering will be required past the implant surgery and point of surgery arrhythmia inductions.
INCLUSION CRITERIA
- Age 18 or above, or legal age to give consent specific to state and national law.
- Any patient undergoing a clinically indicated initial dual chamber T-ICD or CRT-D implantation. In addition, patients who require replacement of an existing dual chamber T-ICD or CRT-D system will be eligible for enrollment in the study.
- Patient will have a subcutaneous, left pectoral defibrillator implant.
EXCLUSION CRITERIA
- Patients unable or unwilling to provide informed consent.
- Any condition which precludes the subject's ability to comply with the study requirements, including completion of the study.
- Patients in chronic atrial fibrillation who have not been in sinus rhythm within the last six months.
- Enrollment in a concurrent study, without Cameron Health's written approval, that may confound the results of this study.
- Women who are pregnant or who are trying to become pregnant Note: Women of child bearing potential must have a negative pregnancy test within 7 days prior to defibrillator implant.
- Patient requires left sub-muscular or right sided defibrillator implant
Studietyp
Inskrivning (Faktisk)
Kontakter och platser
Studieorter
-
-
Illinois
-
Chicago, Illinois, Förenta staterna, 60637
- University of Chicago
-
-
South Carolina
-
Charleston, South Carolina, Förenta staterna, 29425
- Medical University of South Carolina
-
-
Virginia
-
Richmond, Virginia, Förenta staterna, 23298
- Virginia Commonwealth University
-
-
-
-
-
Rotterdam, Nederländerna, 3000 CA
- Erasmus Medical Centre
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
Tar emot friska volontärer
Kön som är behöriga för studier
Testmetod
Studera befolkning
Beskrivning
Inclusion Criteria:
- Age 18 or above, or legal age to give consent specific to state and national law.
- Any patient undergoing a clinically indicated initial dual chamber T-ICD or CRT-D implantation. In addition, patients who require replacement of an existing dual chamber T-ICD or CRT-D system will be eligible for enrollment in the study.
- Patient will have a subcutaneous, left pectoral defibrillator implant
Exclusion Criteria:
- Patients unable or unwilling to provide informed consent.
- Any condition which precludes the subject's ability to comply with the study requirements, including completion of the study.
- Patients in chronic atrial fibrillation who have not been in sinus rhythm within the last six months.
- Enrollment in a concurrent study, without Cameron Health's written approval, that may confound the results of this study.
- Women who are pregnant or who are trying to become pregnant Note: Women of child bearing potential must have a negative pregnancy test within 7 days prior to defibrillator implant.
- Patient requires left sub-muscular or right sided defibrillator implant
Studieplan
Hur är studien utformad?
Designdetaljer
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
Collection of simultaneous cardiac signals representing S-ICD and ICD sensing vectors
Tidsram: 3 years
|
This study will enroll a sufficient number of patients such that a minimum of 50 atrial and 50 ventricular arrhythmic episodes are collected by dedicated and integrated ICD systems and by the simulated S-ICD system
|
3 years
|
Samarbetspartners och utredare
Sponsor
Studieavstämningsdatum
Studera stora datum
Studiestart
Primärt slutförande (Faktisk)
Avslutad studie (Faktisk)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Uppskatta)
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Nyckelord
Ytterligare relevanta MeSH-villkor
Andra studie-ID-nummer
- FACTS S-ICD
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .