Tämä sivu käännettiin automaattisesti, eikä käännösten tarkkuutta voida taata. Katso englanninkielinen versio lähdetekstiä varten.

Bracket Positioning Techniques and Quality of Orthodontic Finishing

perjantai 10. heinäkuuta 2026 päivittänyt: Hager Mansour Abdelbaseer Zoghby, Future University in Egypt

Comparison of Three Bracket Positioning Techniques (Smile Arc Protection, Smile Arc and Marginal Ridge Approach, and McLaughlin-Bennett-Trevisi) on the Quality of Orthodontic Finishing, Mini-Esthetics, and Anterior Tooth Tip and Torque: A Three-Arm Randomized Clinical Trial

This three-arm randomized clinical trial compares three orthodontic bracket positioning techniques - Smile Arc Protection (SAP), Smile Arc and Marginal Ridge Approach (SAMRA), and the McLaughlin-Bennett-Trevisi (MBT) bracket placement chart (control) - in young patients with Angle Class I malocclusion and mild-to-moderate crowding treated non-extraction. The primary aim is to determine which technique yields the highest quality of orthodontic finishing, measured with the American Board of Orthodontics Objective Grading System (ABO-OGS). Secondary aims compare anterior tooth tip and torque (assessed by CBCT) and mini-esthetic smile parameters (gingival display, incisal display, buccal corridor, and smile arc, assessed on standardized posed-smile photographs) among the three techniques.

Tutkimuksen yleiskatsaus

Yksityiskohtainen kuvaus

Bracket positioning is one of the most influential operator-dependent factors affecting the quality of orthodontic finishing and the resulting smile esthetics. Three contemporary positioning philosophies are compared in this trial.

Design. Eligible participants are randomly allocated 1:1:1 to one of three parallel arms. Allocation is generated with an online randomizer, concealed in sequentially opaque sealed envelopes held by a co-supervisor, and revealed only on the day of intervention. Outcome assessors are blinded; operator blinding is not feasible.

Intervention. All arms receive a fully digital indirect-bonding workflow (intraoral scanning, virtual bracket placement in 3Shape Ortho-Analyzer, 3D-printed casts, vacuum-formed transfer trays) using a 0.018-inch MBT prescription, and an identical arch wire sequence ending in a 0.017 in × 0.025 in stainless steel wire maintained for three months. The arms differ only in the vertical/angular bracket-positioning rule applied (SAP, SAMRA, or MBT chart).

Assessment. Records are captured before bonding (T₀) and at the end of levelling and alignment (T₁). The ABO-OGS is scored on 3D-printed casts and the panoramic radiograph; tip and torque are measured on dentoalveolar CBCT; mini-esthetic parameters are measured on standardized frontal posed-smile photographs calibrated in Adobe Photoshop.

Opintotyyppi

Interventio

Ilmoittautuminen (Todellinen)

39

Vaihe

  • Ei sovellettavissa

Yhteystiedot ja paikat

Tässä osiossa on tutkimuksen suorittajien yhteystiedot ja tiedot siitä, missä tämä tutkimus suoritetaan.

Opiskelupaikat

    • Cairo Governorate
      • New Cairo, Cairo Governorate, Egypti, 11835
        • Department of Orthodontics, Faculty of Oral and Dental Medicine, Future University in Egypt, Cairo, Egypt

Osallistumiskriteerit

Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.

Kelpoisuusvaatimukset

Opintokelpoiset iät

  • Lapsi
  • Aikuinen

Hyväksyy terveitä vapaaehtoisia

Ei

Kuvaus

Inclusion Criteria:

  1. Males and females aged 14-25 years with a full permanent dentition.
  2. Mild to moderate crowding requiring non-extraction orthodontic treatment (2-6 mm per Graber's classification).
  3. Angle Class I malocclusion.
  4. Normal skeletal vertical dimension (SN-MP angle 32° ± 5°).

Exclusion Criteria:

  • 1. Medication that may cause gingival inflammation (e.g., cyclosporine, phenytoin).

    2. Impacted, extracted, or missing permanent teeth (except third molars). 3. Periodontal disease or parafunctional habits (bruxism, tongue thrusting, mouth breathing).

    4. History of previous orthodontic treatment. 5. Craniofacial anomalies, facial asymmetry, or skeletal discrepancy.

Opintosuunnitelma

Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.

Miten tutkimus on suunniteltu?

Suunnittelun yksityiskohdat

  • Ensisijainen käyttötarkoitus: Hoito
  • Jako: Satunnaistettu
  • Inventiomalli: Rinnakkaistehtävä
  • Naamiointi: Yksittäinen

Aseet ja interventiot

Osallistujaryhmä / Arm
Interventio / Hoito
Kokeellinen: Group SAP
Bracket positioning by the Smile Arc Protection technique (anterior brackets placed relatively more gingival, referenced to canine crown height).
Bracket positioning by the Smile Arc Protection technique (anterior brackets placed relatively more gingival, referenced to canine crown height).
Kokeellinen: Group SAMRA
Bracket positioning by the Smile Arc and Marginal Ridge Approach (digital workflow referencing the marginal-ridge line and facial axis).
Bracket positioning by the Smile Arc and Marginal Ridge Approach (digital workflow referencing the marginal-ridge line and facial axis).
Active Comparator: Group MBT (Control)
Bracket positioning by the McLaughlin-Bennett-Trevisi bracket placement chart (bracket-to-incisal-edge distances from the standardized chart).
Bracket positioning by the McLaughlin-Bennett-Trevisi bracket placement chart (bracket-to-incisal-edge distances from the standardized chart).

Mitä tutkimuksessa mitataan?

Ensisijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Quality of orthodontic finishing - ABO Objective Grading System (ABO-OGS) total score
Aikaikkuna: At completion of the levelling and alignment phase (T₁), after the 0.017 in × 0.025 in stainless steel arch wire has been maintained for 3 months - approximately 7 months after bonding.
Total ABO-OGS score obtained on the Cast-Radiographic Evaluation (CRE) form. Seven parameters - alignment/rotations, marginal ridges, buccolingual inclination, occlusal contacts, occlusal relationships, overjet, and interproximal contacts - are scored on 3D-printed casts with the ABO measuring gauge; root angulation is scored on the panoramic radiograph. Point deductions are summed to give the total score (a lower total indicates better finishing).
At completion of the levelling and alignment phase (T₁), after the 0.017 in × 0.025 in stainless steel arch wire has been maintained for 3 months - approximately 7 months after bonding.

Toissijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Anterior crown angulation (tip) - CBCT
Aikaikkuna: Change from before bonding (T₀) to end of levelling and alignment (T₁), approximately 7 months after bonding
Change in mesiodistal crown angulation (tip) of the anterior teeth, measured in degrees on dentoalveolar CBCT using defined landmarks and reference planes.
Change from before bonding (T₀) to end of levelling and alignment (T₁), approximately 7 months after bonding
Anterior crown inclination (torque) - CBCT
Aikaikkuna: Change from before bonding (T₀) to end of levelling and alignment (T₁), approximately 7 months after bonding
Change in labiolingual crown inclination (torque) of the anterior teeth, measured in degrees on dentoalveolar CBCT.
Change from before bonding (T₀) to end of levelling and alignment (T₁), approximately 7 months after bonding
Maxillary gingival display
Aikaikkuna: Change from before bonding (T₀) to end of levelling and alignment (T₁), approximately 7 months after bonding
Change in maxillary gingival display - the vertical distance (mm) between the inferior border of the upper lip and the gingival zenith of each maxillary anterior tooth (central incisor, lateral incisor, canine, both sides) on standardized posed-smile frontal photographs, measured in Adobe Photoshop after calibration against a metric ruler.
Change from before bonding (T₀) to end of levelling and alignment (T₁), approximately 7 months after bonding
Maxillary incisal display
Aikaikkuna: Change from before bonding (T₀) to end of levelling and alignment (T₁), approximately 7 months after bonding
Change in maxillary incisal display - the vertical amount (mm) of maxillary incisor crown visible relative to the upper lip during a posed smile, on standardized photographs.
Change from before bonding (T₀) to end of levelling and alignment (T₁), approximately 7 months after bonding
Buccal corridor width
Aikaikkuna: Change from before bonding (T₀) to end of levelling and alignment (T₁), approximately 7 months after bonding
Change in buccal corridor (lateral negative space) - the linear distance (mm) between the most posterior visible maxillary tooth and the corner of the mouth during posed smile, measured on each side and averaged.
Change from before bonding (T₀) to end of levelling and alignment (T₁), approximately 7 months after bonding
Smile arc category
Aikaikkuna: Change from before bonding (T₀) to end of levelling and alignment (T₁), approximately 7 months after bonding
Smile arc classified as consonant, flat, or reversed based on the relationship between the curvature of the maxillary incisal/canine/premolar edges and the curvature of the lower lip during posed smile.
Change from before bonding (T₀) to end of levelling and alignment (T₁), approximately 7 months after bonding

Yhteistyökumppanit ja tutkijat

Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.

Opintojen ennätyspäivät

Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan ​​julkisella verkkosivustolla.

Opi tärkeimmät päivämäärät

Opiskelun aloitus (Todellinen)

Maanantai 1. heinäkuuta 2024

Ensisijainen valmistuminen (Todellinen)

Keskiviikko 1. heinäkuuta 2026

Opintojen valmistuminen (Todellinen)

Keskiviikko 1. heinäkuuta 2026

Opintoihin ilmoittautumispäivät

Ensimmäinen lähetetty

Tiistai 7. heinäkuuta 2026

Ensimmäinen toimitettu, joka täytti QC-kriteerit

Perjantai 10. heinäkuuta 2026

Ensimmäinen Lähetetty (Todellinen)

Torstai 16. heinäkuuta 2026

Tutkimustietojen päivitykset

Viimeisin päivitys julkaistu (Todellinen)

Torstai 16. heinäkuuta 2026

Viimeisin lähetetty päivitys, joka täytti QC-kriteerit

Perjantai 10. heinäkuuta 2026

Viimeksi vahvistettu

Keskiviikko 1. heinäkuuta 2026

Lisää tietoa

Tähän tutkimukseen liittyvät termit

Yksittäisten osallistujien tietojen suunnitelma (IPD)

Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?

PÄÄTTÄMÄTÖN

IPD-suunnitelman kuvaus

Study data are stored confidentially within the Department of Orthodontics with access restricted to the investigator and supervisors; results will be disseminated through the institutional thesis repository and peer-reviewed publication.

Lääke- ja laitetiedot, tutkimusasiakirjat

Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta

Ei

Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta

Ei

Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .

Tilaa