Tämä sivu käännettiin automaattisesti, eikä käännösten tarkkuutta voida taata. Katso englanninkielinen versio lähdetekstiä varten.

TransThoracic Ultrasound for Descending Aortic Aneurysms (THORUS)

maanantai 3. elokuuta 2026 päivittänyt: Imperial College London

Feasibility, Accuracy and Reproducibility of Ultrasound in Aneurysms of the Descending Thoracic Aorta

The goal of this observational study is to assess the applicability of non-invasive ultrasound in aneurysms of the descending thoracic aorta.

The main question it aims to answer is:

What is the feasibility of Ultrasound to visualise the Descending Thoracic Aorta, and can this imaging modality accurately measure the maximum size of aneurysms and residual sacs with acceptable reproducibility?

Participants are having their diagnosis confirmed or excluded by conventional imaging techniques (CT scans). Participants receive exactly the same standard of care regardless of their participation. The study offers an additional ultrasound scan, and the results will be compared with previous imaging.

Tutkimuksen yleiskatsaus

Yksityiskohtainen kuvaus

Aneurysms of the aortic artery are a significant public health issue. The number of newly diagnosed aneurysms of the thoracic aorta is on the rise, and aneurysm rupture is a catastrophic event associated with high mortality rates. The most proximal sections of the aorta (ascending and the aortic arch) are routinely scanned by echocardiography practitioners. The abdominal aorta is also easily visualised on transabdominal ultrasound, and there is a screening programme in the UK that is highly cost-effective and reduced the aneurysm-related number of deaths. However, the portion of the aorta in the chest (descending thoracic aorta) is not routinely assessed by ultrasound practitioners.

The diagnosis of descending thoracic aneurysms relies mostly on imaging techniques that use ionising radiation. In addition, these techniques are expensive and may not be widely available in some regions. In contrast, ultrasound is a non-invasive technique that allows visualisation of most parts of the body. Ultrasound machine suppliers have invested in better systems and transducers over the years and visualisation of the descending thoracic aorta may now be possible.

The main aims of this study are to assess the feasibility (Part 1), accuracy (Part 2) and reproducibility (Part 3) ultrasound in the diagnosis and monitoring of descending thoracic aortic aneurysms. Participants will be recruited from the vascular lab and outpatient clinics, and diameters of the descending thoracic aorta will be measured with non-invasive ultrasound. Data obtained from study measurements will be compared with computed tomography scans that patients had as part of their standard of care.

If the feasibility, accuracy and reproducibility of Ultrasound are clearly demonstrated, routine ultrasound scans of the descending thoracic aorta may be suggested.

Opintotyyppi

Havainnollistava

Ilmoittautuminen (Arvioitu)

60

Yhteystiedot ja paikat

Tässä osiossa on tutkimuksen suorittajien yhteystiedot ja tiedot siitä, missä tämä tutkimus suoritetaan.

Opiskeluyhteys

  • Nimi: Carlos Pinho, PhD Student
  • Puhelinnumero: +44 20 3312 3374
  • Sähköposti: cv1026@ic.ac.uk

Tutki yhteystietojen varmuuskopiointi

Opiskelupaikat

    • London
      • London, London, Yhdistynyt kuningaskunta, W2 1NY
        • Imperial College Healthcare NHS Trust - St Mary's Hospital
        • Ottaa yhteyttä:
          • Carlos Pinho, PhD Student
          • Puhelinnumero: +44 20 3312 3374
          • Sähköposti: cv1026@ic.ac.uk
        • Ottaa yhteyttä:
        • Päätutkija:
          • Carlos Pinho, PhD Student

Osallistumiskriteerit

Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.

Kelpoisuusvaatimukset

Opintokelpoiset iät

  • Aikuinen
  • Vanhempi Aikuinen

Hyväksyy terveitä vapaaehtoisia

Joo

Näytteenottomenetelmä

Ei-todennäköisyysnäyte

Tutkimusväestö

All Participants will receive a single Ultrasound scan as part of this study. All Patients had at least one CT scan of the thoracic aorta prior to the study as part of their standard of care. No additional radiation or invasive imaging techniques will be used in the Thorus study. The data obtained from the CT will be analysed by an independent reviewer and compared with Ultrasound measurements. Participants will be recruited prospectively from a single NHS Trust in London - Imperial College Healthcare NHS Trust.

Kuvaus

Inclusion Criteria:

  • Patients with diagnosed AAA or other vascular condition attending the vascular scanning department for routine ultrasound and confirmed healthy DTA (Control group).
  • Patients with known DTAA (including Type B dissection) or patients who had TEVAR previously (Case group).
  • Patients who have had CT as part of their standard of care.
  • Patients able to tolerate the scan (Lying in supine position).
  • Adults aged 18 or over.
  • Willing to provide consent.

Exclusion Criteria:

  • Patient under 18 years of age.
  • Previous thoracic surgery or body deformity (severe kyphosis, scoliosis, pleural effusion or chest wall trauma).
  • Patients without previous imaging of the thoracic aorta.
  • Life expectancy <2 years.
  • Pregnant Women.
  • Patients unwilling to provide consent or unable to comply with study requirements.
  • Patients too frail to travel to routine outpatient appointments.
  • Inability to attend the appointment due to time constraints or other commitments.
  • Although rare, ultrasound contraindications as described in the scanning protocol are also exclusion criteria.

Opintosuunnitelma

Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.

Miten tutkimus on suunniteltu?

Suunnittelun yksityiskohdat

Kohortit ja interventiot

Ryhmä/Kohortti
CONTROLS
Patients with healthy DTA (30 patients)
CASES
Patients with DTAA or TEVAR (30 patients)

Mitä tutkimuksessa mitataan?

Ensisijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Part 1 - Feasibility - Proportion of participants with successful ultrasound measurement of the diameter of the descending thoracic aorta
Aikaikkuna: Day 1 - At the single ultrasound study visit.
Number and percentage of participants in whom the descending thoracic aortic diameter can be obtained by transthoracic ultrasound. The units of Measure are total number and percentages.
Day 1 - At the single ultrasound study visit.
Part 1 - Feasibility - Length of the descending thoracic aorta by Ultrasound
Aikaikkuna: Day 1 - At the single ultrasound study visit.
Total length of the descending thoracic aorta from the aortic isthmus to the coeliac axis. The unit of Measure is Centimetres (cms).
Day 1 - At the single ultrasound study visit.
Part 1 - Feasibility - Ultrasound Quality Score
Aikaikkuna: Day 1 - At the single ultrasound study visit.

Number of ultrasound windows that allow visualisation of the descending thoracic aorta (0 to 3 windows) and allocation of a quality score.

The Unit of Measure is a score created for this study (0-Windows: No views; 1 window: Poor; 2 windows: Moderate; 3 windows: Good). Higher scores mean better image quality.

Day 1 - At the single ultrasound study visit.
Part 2 - Accuracy - Comparision between Transthoracic Ultrasound and CT
Aikaikkuna: Day 1 - At the single ultrasound study visit.
Calculate mean differences and limits of agreement between TUS and CT. Achieve high sensitivity and specificity.
Day 1 - At the single ultrasound study visit.
Part 3 - Reproducibility - Intraclass correlation coefficient
Aikaikkuna: Day 1 - At the single ultrasound study visit.
Calculate inter- and intra-operator variability by intraclass correlation coefficient (ICC). The study aims to achieve good or excellent reliability.
Day 1 - At the single ultrasound study visit.

Toissijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Part 1 - Feasibility - Factors limiting visualisation of the Descending Thoracic Aorta
Aikaikkuna: Day 1 - At the single ultrasound study visit.
Number and percentages of participants in whom limiting factors such as body habitus or rib shadowing are reported after the ultrasound test. The units of measure are the number of participants with raised BMI (kg/m^2) and acoustic shadowing due to bone density.
Day 1 - At the single ultrasound study visit.
Part 1 - Feasibility - Duration of Ultrasound Examination
Aikaikkuna: Day 1 - At the single ultrasound study visit.
Total time needed to complete the ultrasound scan of the descending thoracic aorta. The unit of measure is minutes.
Day 1 - At the single ultrasound study visit.
Part 1 - Feasibility - Patient Feedback Questionnaire
Aikaikkuna: Day 1 - At the single ultrasound study visit.
Scores are obtained from the patient feedback questionnaire that was created specifically for this study and consists of 5 questions relating to comfort, tolerability and overall experience of the ultrasound scan. The unit of measure is a score ranging from 1-Strongly Disagree to 5-Strongly Agree. Higher scores mean better patient satisfaction.
Day 1 - At the single ultrasound study visit.

Yhteistyökumppanit ja tutkijat

Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.

Tutkijat

  • Opintojen puheenjohtaja: Professor Colin Bicknell, Imperial College London

Opintojen ennätyspäivät

Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan ​​julkisella verkkosivustolla.

Opi tärkeimmät päivämäärät

Opiskelun aloitus (Arvioitu)

Maanantai 7. syyskuuta 2026

Ensisijainen valmistuminen (Arvioitu)

Maanantai 5. huhtikuuta 2027

Opintojen valmistuminen (Arvioitu)

Maanantai 3. huhtikuuta 2028

Opintoihin ilmoittautumispäivät

Ensimmäinen lähetetty

Tiistai 28. heinäkuuta 2026

Ensimmäinen toimitettu, joka täytti QC-kriteerit

Maanantai 3. elokuuta 2026

Ensimmäinen Lähetetty (Todellinen)

Perjantai 7. elokuuta 2026

Tutkimustietojen päivitykset

Viimeisin päivitys julkaistu (Todellinen)

Perjantai 7. elokuuta 2026

Viimeisin lähetetty päivitys, joka täytti QC-kriteerit

Maanantai 3. elokuuta 2026

Viimeksi vahvistettu

Lauantai 1. elokuuta 2026

Lisää tietoa

Tähän tutkimukseen liittyvät termit

Muut tutkimustunnusnumerot

  • 199470
  • IRAS Project ID: 365629 (Muu tunniste: NHS Health Research Authority)

Yksittäisten osallistujien tietojen suunnitelma (IPD)

Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?

EI

IPD-suunnitelman kuvaus

Sharing IPD is not required to answer the research question.

Lääke- ja laitetiedot, tutkimusasiakirjat

Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta

Ei

Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta

Ei

Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .

Tilaa