- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT00639405
Evaluation of MRI and SPECT Fusion Software to Localize Parathyroid Adenomas
Localization of Parathyroid Adenomas Using MRI and SPECT Fusion Software in Patients With Persistent or Recurrent Hyperparathyroidism
Aperçu de l'étude
Statut
Les conditions
Description détaillée
While a successful neck exploration for PHP is primarily dependent on the experience of the surgeon, there are currently several localizing studies available to increase success. Although the necessity of localizing studies pre-operatively for first time neck explorations is still under debate, there is no question of their importance for persistent or recurrent PHP that requires re-operation. Localizing studies in these patients have been clearly shown to reduce operating time, avoid unnecessary dissection, reduce morbidity, and improve success rate.
Several modalities have been employed for localization such as ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI). The sensitivity of ultrasound for the preoperative detection of parathyroid adenomas has been reported to be 65-90% (1). There are however, limitations to US. Because of the sonolucent appearance of parathyroid adenomas, it is impossible to distinguish an ectopic cervical parathyroid adenoma from a pathologic lymph node. Furthermore, mediastinal parathyroid adenomas are difficult, if not impossible to visualize due to acoustic shadowing from the sternum and clavicles (2). Also, this method is very operator-dependent. MRI has a slightly higher sensitivity of 62.5-94% while CT has a poor sensitivity of only 40-44% (1).
We are using dual-phase single photon emission tomography (SPECT) imaging with technetium 99m sestamibi and visual thyroid subtraction with technetium 99m as pertechnetate. This method can achieve sensitivities of 68-95% and specificities of 75-100% (1). SPECT imaging is dependent on the differential washout of sestamibi between normal thyroid tissue and abnormal parathyroid tissue. Theoretically, sestamibi will washout of normal thyroid tissue much more quickly than it will from abnormal parathyroid tissue. Therefore, SPECT imaging is usually performed immediately and then at 90 and 180 minutes after sestamibi injection. SPECT imaging, however, has several limitations, not the least of which is its inability to provide discrete anatomic detail.
In addition, we will use a control group of patients who have parathyroid adenomas but who have not yet had surgery to test the efficacy of our fusion software.
Our goal is to acquire MRI and SPECT imaging with fiducial markers and utilize fusion software to create a detailed anatomic map of the neck for more accurate localization of the lesion.
Type d'étude
Inscription (Réel)
Contacts et emplacements
Lieux d'étude
-
-
New York
-
Syracuse, New York, États-Unis, 13210
- SUNY Upstate Medical University
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- Subjects who are 18 years and over
- subjects who have had a failed parathyroidectomy and now presents with persistent hyperparathyroidism or recurrent hyperparathyroidism
- 6 control patients with parathyroid adenomas who have not yet had surgery will be selected to test the efficacy of the software.
Exclusion Criteria:
- Potential female subjects who are pregnant
- Any potential subject who has an implanted metallic device, stent or staples
- any subject weighing 300lb
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Modèles d'observation: Cas uniquement
- Perspectives temporelles: Éventuel
Cohortes et interventions
Groupe / Cohorte |
|---|
|
1
subjects who are diagnosed with parathyroid adenomas.
There will be 6 subjects who have not had surgery and 25 subjects who have had surgery.
|
Collaborateurs et enquêteurs
Les enquêteurs
- Chercheur principal: Michele Lisi, MD, State University of New York - Upstate Medical University
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Estimation)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- SUNYUMU 5260
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .