Duchenne Muscular Dystrophy Clinical Trial (DMD)
Double-blind, Randomized, Placebo-controlled Study of VECTTOR Treatment for Duchenne Muscular Dystrophy
The primary objective of this investigation is to assess the effectiveness of transcutaneous electrical nerve stimulation applied using VECTTOR to reduce the symptoms of Duchenne Muscular Dystrophy and reduce the impact of DMD upon the participants' quality of life.
The primary outcome measures will include:
- increased muscle strength,
- increased range of joint motions and
- improved sleep parameters of ASI, N3 and REM.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Muscle Strength and Joint Range of Motion Testing - All muscle and joint testing was performed at the MedCenter Therapy clinic in Houston, Texas. JTech computerized testing system was utilized including Goniometry, Grip testing, Inclinometry, Muscle Testing and Joint Range of Motion testing occurred on Day 0, 30, 60, 90, 180, and repeated at 12 months to determine muscular strength and joint Range of Motion. JTech computerized testing system was chosen on the basis of reliability and accuracy. At each of the testing intervals, the testing was administered by the same technician with the same equipment to all of the participants. Inter-and intra-tester reliability of the JTech computerized testing system has been the subject of multiple studies. Each of which found high ICCs (>0.93) for both inter- and intra-tester reliability.
All sleep studies were performed at Sleep Diagnostics of Texas in The Woodlands, Texas. Prior to the clinical trial, all of the participants spent two nights in the sleep unit and their sleep study examinations were performed. The second night was used as the Day 0 data. Sleep, breathing, arousals and limb movements were scored manually according to guidelines set forth by the American Academy of Sleep Medicine. The sleep studies were repeated at 6 months and 1 year.
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
Texas
-
Houston, Texas, États-Unis, 77004
- Alan Neuromedical
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Participants must have Duchenne Muscular Dystrophy diagnosis as confirmed by licensed physician, wheelchair bound, & age 8 - 20 years old.
Exclusion Criteria:
- Active cancer in the area of application of the treatment, infection, skin infection, pregnancy, thrombophlebitis, pacemaker, amputation of any part of feet or hands, taking steroids. In addition, the participant may not be in any other clinical trial during the time they are in this study.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: Randomisé
- Modèle interventionnel: Affectation croisée
- Masquage: Quadruple
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: VECTTOR
nerve stimulator treatment twice daily for duration of study - 365 days
|
The VT-200, or VECTTOR system, delivers electrical stimulation via electrodes on the acupuncture points of a patient's feet/legs and hands/arms to provide symptomatic relief of chronic intractable pain and/or management of post-surgical pain. Once these electrodes are placed, the machine determines the appropriate choice of stimulation by automatically measuring body temperatures through the use of thermistors placed on the fingers during a testing sequence.
Autres noms:
|
|
Comparateur placebo: Device - sham
placebo treatment - no electrical stimulation treatment twice daily for duration of study, 180 days - if VECTTOR arm experiencing improvement, subjects in Device-Sham arm will be crossed over into the VECTTOR group and followed for an additional 180 days, for a total study involvement (duration) of 365 days>
|
The VT-200, or VECTTOR system, delivers electrical stimulation via electrodes on the acupuncture points of a patient's feet/legs and hands/arms to provide symptomatic relief of chronic intractable pain and/or management of post-surgical pain. Once these electrodes are placed, the machine determines the appropriate choice of stimulation by automatically measuring body temperatures through the use of thermistors placed on the fingers during a testing sequence.
Autres noms:
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Percent Change in Range of Motion From Baseline to 180 Days
Délai: Baseline to 180 days
|
Range of Motion (ROM) testing (Wireless Tracker System) - All muscle and joint testing was performed using the JTech computerized testing system, including Goniometry, Grip Testing, Inclinometry, Muscle Testing and Joint Range of Motion.
Testing occurred at Baseline (Day 0), 30, 60, 90 and 180 days to determine changes in joint Range of Motion.
JTech computerized testing system determined the joint range of motion by radio signals from a goniometer measuring movement of the participants' joints.
44 separate tests were performed for Range of Motion for each participant at each time interval.
The results from the range of motion tests were averaged the percent change from baseline to 180 days.
Efficacy is defined as an increase in range of motion.
|
Baseline to 180 days
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Percent Change in Muscle Strength
Délai: Baseline to 180 days
|
Muscle strength testing (Wireless Tracker system) - All muscle strength testing was performed using the JTech computerized testing system, including Goniometry, Grip Testing, Inclinometry, Muscle Testing and Joint Range of Motion.
Testing occurred at Baseline (Day 0), 30, 60, 90, and 180 days to determine changes in muscle strength.
JTech computerized testing system determined the muscle strength by radio signals from a strain gauge measuring strength of the participant's muscles.
44 separate tests were performed for muscle strength for each participant at each time interval.
Efficacy is defined as an increase in the strength measurement (pounds) from Baseline to 180 days.
|
Baseline to 180 days
|
|
Percent Change in Percent Range of Motion From Baseline to 365 Days
Délai: Baseline to 365 days
|
Range of Motion (ROM) testing (Wireless Tracker System) - All muscle and joint testing was performed using the JTech computerized testing system, including Goniometry, Grip Testing, Inclinometry, Muscle Testing and Joint Range of Motion.
Testing occurred at Baseline (Day 0), 30, 60, 90, 180 and 365 days to determine changes in joint Range of Motion.
JTech computerized testing system determined the joint range of motion by radio signals from a goniometer measuring movement of the participants' joints.
44 separate tests were performed for Range of Motion for each participant at each time interval.
The results from the range of motion tests were averaged the percent change from baseline to 365 days.
Efficacy is defined as an increase in range of motion.
|
Baseline to 365 days
|
|
Percent Change in Muscle Strength
Délai: Baseline to 365 days
|
Muscle strength testing (Wireless Tracker system) - All muscle strength testing was performed using the JTech computerized testing system, including Goniometry, Grip Testing, Inclinometry, Muscle Testing and Joint Range of Motion.
Testing occurred at Baseline (Day 0), 30, 60, 90, 180 and 365 days to determine changes in muscle strength.
JTech computerized testing system determined the muscle strength by radio signals from a strain gauge measuring strength of the participant's muscles.
44 separate tests were performed for muscle strength for each participant at each time interval.
Efficacy is defined as an increase in the strength measurement (pounds) from Baseline to 365 days.
|
Baseline to 365 days
|
Autres mesures de résultats
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Percent Change in Sleep Quality Arousal Statistics Index (ASI) From Baseline to 180 Days
Délai: Baseline to 180 days
|
Sleep / Arousal Statistics Index (ASI) description: Sleep Studies were obtained twice before beginning the study.
The second sleep study data was used as baseline.
A follow up sleep study was obtained after 6 months (180 days) of Active or Placebo VECTTOR treatment.
Sleep, breathing, arousal(s), and limb movements were scored manually according to guidelines of the American Academy of Sleep Medicine.
The efficacy of the outcome measure of ASI is demonstrated by a percent improvement between Baseline and 180 days.
The ASI is measured by the number of times sleep is interrupted per hour.
|
Baseline to 180 days
|
|
Sleep Arousal Statistics Index at 365 Days
Délai: Baseline to 365 days
|
Sleep / Arousal Statistics Index (ASI) description: Sleep Studies were obtained twice before beginning the study.
The second sleep study data was used as baseline.
A follow up sleep study was obtained after 6 months (180 days) of Active or Placebo VECTTOR treatment.
Sleep, breathing, arousal(s), and limb movements were scored manually according to guidelines of the American Academy of Sleep Medicine.
The efficacy of the outcome measure of ASI is demonstrated by a decrease in the value between Baseline and 180 days.
The ASI is measured by the number of times sleep is interrupted per hour.
Lower ASI values/numbers indicate improved sleep quality.
|
Baseline to 365 days
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Charlotte Stelly-Seitz, MD, Pediatric Physical Medicine and Rehabilitation Houston, Texas
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Estimation)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- VECTTOR DMD2012
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .