- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT02280512
Intra-op Monitoring With NIRS and NICOM, and Surgical Outcome in Elderly Patients With Fractures of Lower Limbs
Intraoperative Monitoring With Noninvasive Near-infrared Spectroscopy and Noninvasive Cardiac Output Measurement, and Postoperative Outcome in Elderly Patients With Fractures of Lower Extremities
In Taiwan, about 75.92% of the elderlies above 65 years old suffered from chronic diseases or major diseases, especially in circulatory system. Thus, dramatic hemodynamic change is often observed in surgeries in this population. Due to osteoporosis and high-prevalence morbidities, trauma with fracture is quite common. These elderlies are more vulnerable to have complications, poor prognosis and decompensated organ functions.
The investigators would like to observe the perfusion of different tissue intra-operatively, and to find the correlation with surgical outcome. There are many non-invasive hemodynamic monitors nowadays. In our study, the investigators will use noninvasive cardiac output measurement(NICOM), and non-invasive transcutaneous near infrared spectroscopy(NIRS) to observe hemodynamic change and tissue perfusion. After the surgery, the duration in ICU will be recorded. A questionnaire, SF-36, will be mailed to the patients 2 months after the surgery to measure the psychometric status.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Aging is associated with progressive loss of functional reserve in all organ systems. For most people, physiologic compensation for age-related changes is adequate. However, it is easy to decompensate under stressful circumstances, such as surgery and illness. Under the specific physiologic phenomenon, geriatric anesthesia is acquired for more intensive monitoring. In Taiwan, about 75.92% of the elderlies above 65 years old suffered from chronic diseases or major diseases, especially in circulatory system. Thus, dramatic hemodynamic change is often observed in surgeries in this population. For the elderlies with fracture are more vulnerable to have complications, poor prognosis and decompensated organ functions.
In our daily practice, the surgeries for fracture in lower extremities can performed under either general anesthesia or regional anesthesia, such as spinal anesthesia epidural anesthesia, and nerve block. The anesthetic method is determined under each patient's condition. EKG, arterial catheter, pulse oximeter are usually basic for intra-operative monitoring. However, these tools are unable to inform us the real-time cardiac output and the exact status of tissue perfusion. Nowadays, there are many non-invasive instruments able to estimate more detailed hemodynamic parameters, which are very crucial during anesthesia.1 But these instruments are not widely used in our daily practices. We need more researches to support the beneficial roles of these non-invasive monitors to high-risk patients during surgery.
Due to the hemodynamic feature in elderlies, we will use conventional measurements as EKG, arterial blood pressure and pulse oximeter. To measure the perfusion of the lower extremities, we use a relative new tool, the non-invasive transcutaneous near infrared spectroscopy (NIRS).2,3 NIRS was used as the cerebral oximetry to measure the tissue perfusion of the cerebral cortex. It uses reflectance oximetry to measure the oxygen saturation of the tissue underneath the sensor.1 Recently, NIRS has been proved not only to continuously monitor tissue oxygenation saturation (StO2) continuously, but also to predict the patient's poor prognosis.3,4 To measure the cardiac output intra-operatively, we will use the non-invasive cardiac output monitor (NICOM®, Cheetah). Bioreactance technique allows the measurement of hemodynamic changes via four electrodes placed on the thorax. The electrical current crossing the thorax makes "signal phase shift", which is related to changes in the volume of the thoracic aorta. Thus, the volume change in the thoracic aorta is able to estimate stroke volume.1,5 Postoperative prognosis is adjusted with the recovery of ambulation, the duration of ICU stay, the morbidity and mortality, and the questionnaire (SF-36) about quality of life.
Type d'étude
Inscription (Anticipé)
Contacts et emplacements
Lieux d'étude
-
-
-
Taipei, Taïwan, 100
- National Taiwan University Hospital
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
La description
Inclusion criteria:
- Patients more than 65 years old accepting surgeries for lower extremities fracture
Exclusion criteria:
- Skin lesions over the sites where NIRS patches and NICOM electrodes are about to be attached.
- Patients with history of being allergic to NIRS patches or NICOM electrodes.
- Patients with pleural effusion or pericardial effusion.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Cohortes et interventions
Groupe / Cohorte |
Intervention / Traitement |
|---|---|
|
elderly with fractures
patients more than 65 years old accepting surgeries for lower extremities fracture
|
hemodynamic monitoring with NICOM and tissue perfusion monitoring with NIRS
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Psychometric status in 3 months after the surgery
Délai: 3 months
|
Evaluation via questionnaire, SF-36
|
3 months
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
ICU stay
Délai: 2 Days
|
If the patient was admitted to intensive care units(ICU) after the operation, the duration of staying in ICU is recorded.
|
2 Days
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Po-Yuan Shih, National Taiwan University
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Anticipé)
Achèvement de l'étude (Anticipé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Estimation)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- 201407114RIND
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .