- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT03057782
Innovative Approaches to Assessment of Pain Control and Sedation in the NICU
Aperçu de l'étude
Statut
Les conditions
Description détaillée
This is a prospective, non-interventional study designed to assess noxious-specific neurophysiologic responses and clinical signs following procedural pain in infants requiring hospitalization in the neonatal intensive care unit (NICU) following elective surgery.
The main goal of the study is to develop a method that reliably quantifies the level of pain induced from clinically-required noxious procedures to infants hospitalized in the NICU. This method will use measures of neurophysiological, autonomic, and behavioral responses to non-noxious and clinically-required noxious stimuli in order to guide the pharmacological treatment of NICU patients with analgesic agents, sedatives and/or muscle relaxants.
The investigators hypothesize that resting state activity and physiological responses to noxious and non-noxious stimuli provide a more reliable assessment of the level of pain of infants hospitalized in the NICU compared to behavioral-based pain scores.
Type d'étude
Inscription (Anticipé)
Contacts et emplacements
Lieux d'étude
-
-
Massachusetts
-
Boston, Massachusetts, États-Unis, 02115
- Boston Children's Hospital
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- All patients will be admitted to the NICU, and having a post-menstrual age of >28 weeks. Participants will be divided into four groups according to the following criteria:
Group A
- Plan for major surgery anticipated to cause pain and agitation (i.e. esophageal atresia treatment);
- Patients who are anticipated to receive prolonged post-surgical neuromuscular blockade
Group B
- Plan for major surgery anticipated to cause pain and agitation (i.e. bowel surgery);
- Patients who are not anticipated to receive acute post-surgical neuromuscular blockade
Group C Plan for minor surgery anticipated to cause pain and agitation (i.e. hernia repair);
Group D No plan for surgery
Exclusion Criteria:
- Confirmed or suspected clinical seizures
- Metabolic abnormalities or inborn error of metabolism
- Skin abrasions or wounds located at the site of research sensor placement i.e. scalp, which interfere with the application of electrodes
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Modèles d'observation: Cohorte
- Perspectives temporelles: Éventuel
Cohortes et interventions
Groupe / Cohorte |
Intervention / Traitement |
|---|---|
|
Group A
The following devices will be used in this Group: Waveguard (TM) EEG cap; Micro Movement Sensor; Pico Movement Sensor; QS Piezostimulator; tactileTM sensory evaluator. These subjects will also receive EMG monitoring. Subjects in this group will also have video recordings that may be used for novel analysis such as subdermal blood flow or micro-movement. |
The device is an EEG cap - a non-invasive EEG positioning system used to quickly place a large number of surface electrodes in a quick and consistent manner on the head.
The device will measure electrophysiological signals from the scalp at the time points in the study listed in the protocol.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor breathing and movement in children; the device is not used for validation purposes.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor respiration rate and gross body movement in children.
The device will not be used for validation purposes.
This device is not FDA approved.
This device is used for research purposes by neurologists and physiologists.
It is a mechanical tactile stimulator for use in functional imaging experiments like MEG, fMRI or EEG.
The stimulation is realized by using several different pin matrices.
In this study, the device is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
This device is not FDA approved.
This device is used for clinical and research purposes by neurologists and physiologists.
It is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
|
|
Group B
The following devices will be used in this Group: Waveguard (TM) EEG cap; Micro Movement Sensor; Pico Movement Sensor; QS Piezostimulator; tactileTM sensory evaluator. Subjects in this group will also have video recordings that may be used for novel analysis such as sub-dermal blood flow or micro-movement. |
The device is an EEG cap - a non-invasive EEG positioning system used to quickly place a large number of surface electrodes in a quick and consistent manner on the head.
The device will measure electrophysiological signals from the scalp at the time points in the study listed in the protocol.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor breathing and movement in children; the device is not used for validation purposes.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor respiration rate and gross body movement in children.
The device will not be used for validation purposes.
This device is not FDA approved.
This device is used for research purposes by neurologists and physiologists.
It is a mechanical tactile stimulator for use in functional imaging experiments like MEG, fMRI or EEG.
The stimulation is realized by using several different pin matrices.
In this study, the device is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
This device is not FDA approved.
This device is used for clinical and research purposes by neurologists and physiologists.
It is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
|
|
Group C
Plan for minor surgery anticipated to cause pain and agitation (i.e. hernia repair) The following devices will be used in this Group: Waveguard (TM) EEG cap; Micro Movement Sensor; Pico Movement Sensor; QS Piezostimulator; tactileTM sensory evaluator. Subjects in this group will also have video recordings that may be used for novel analysis such as sub-dermal blood flow or micro-movement. |
The device is an EEG cap - a non-invasive EEG positioning system used to quickly place a large number of surface electrodes in a quick and consistent manner on the head.
The device will measure electrophysiological signals from the scalp at the time points in the study listed in the protocol.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor breathing and movement in children; the device is not used for validation purposes.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor respiration rate and gross body movement in children.
The device will not be used for validation purposes.
This device is not FDA approved.
This device is used for research purposes by neurologists and physiologists.
It is a mechanical tactile stimulator for use in functional imaging experiments like MEG, fMRI or EEG.
The stimulation is realized by using several different pin matrices.
In this study, the device is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
This device is not FDA approved.
This device is used for clinical and research purposes by neurologists and physiologists.
It is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
|
|
Group D
No plan for surgery The following devices will be used in this Group: Waveguard (TM) EEG cap; Micro Movement Sensor; Pico Movement Sensor; QS Piezostimulator; tactileTM sensory evaluator. Subjects in this group will also have video recordings that may be used for novel analysis such as sub-dermal blood flow or micro-movement. |
The device is an EEG cap - a non-invasive EEG positioning system used to quickly place a large number of surface electrodes in a quick and consistent manner on the head.
The device will measure electrophysiological signals from the scalp at the time points in the study listed in the protocol.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor breathing and movement in children; the device is not used for validation purposes.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor respiration rate and gross body movement in children.
The device will not be used for validation purposes.
This device is not FDA approved.
This device is used for research purposes by neurologists and physiologists.
It is a mechanical tactile stimulator for use in functional imaging experiments like MEG, fMRI or EEG.
The stimulation is realized by using several different pin matrices.
In this study, the device is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
This device is not FDA approved.
This device is used for clinical and research purposes by neurologists and physiologists.
It is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Noxious Stimuli Results
Délai: Up to 1 year
|
To assess pain-specific brain activity and autonomic responses post surgery in response to an acute noxious procedure in newborn infants admitted to the NICU. This outcome will be correlated with current behavioral and physiological based pain assessment tools as follows: Procedural-specific brain activity in infants with varying conditions with pre or post-operative pain. EEG: amplitude of noxious-event related potential evoked by a time-locked noxious stimulus. Pain-specific electro-dermal activity (EDA), electromyography (EMG) and subdermal skin flow; Pain-evoked behavioral measures including: Body movement; Eye squeeze, brow bulge and nasolabial furrow duration. Pain-evoked physiological measures including: Respiration rate; Heart rate; Blood pressure; Oxygen saturation; Observational pain scores (PIPP); EMG activity. |
Up to 1 year
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Resting State Results
Délai: Up to 1 year
|
Characterize resting state activity in post-operative or control subjects as follows: Baseline brain (EEG) activity (power spectra of baseline EEG signal) in post operative or control subjects. Baseline EDA, EMG and subdermal skin flow; Baseline behavioral measures including: Presence of body movement, eye squeeze, brow bulge and nasolabial furrow. Baseline physiological measures including: Respiration rate; Heart rate; Blood pressure; Oxygen saturation; Observational pain scores (PIPP). The relationship with resting brain activity, electrodermal activity, behavior, physiological, and observational pain scores will be evaluated. |
Up to 1 year
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Laura Cornelissen, PhD, Boston Children's Hospital
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- IRB-P00022180
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .