- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT03057782
Innovative Approaches to Assessment of Pain Control and Sedation in the NICU
Przegląd badań
Status
Warunki
Szczegółowy opis
This is a prospective, non-interventional study designed to assess noxious-specific neurophysiologic responses and clinical signs following procedural pain in infants requiring hospitalization in the neonatal intensive care unit (NICU) following elective surgery.
The main goal of the study is to develop a method that reliably quantifies the level of pain induced from clinically-required noxious procedures to infants hospitalized in the NICU. This method will use measures of neurophysiological, autonomic, and behavioral responses to non-noxious and clinically-required noxious stimuli in order to guide the pharmacological treatment of NICU patients with analgesic agents, sedatives and/or muscle relaxants.
The investigators hypothesize that resting state activity and physiological responses to noxious and non-noxious stimuli provide a more reliable assessment of the level of pain of infants hospitalized in the NICU compared to behavioral-based pain scores.
Typ studiów
Zapisy (Oczekiwany)
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Massachusetts
-
Boston, Massachusetts, Stany Zjednoczone, 02115
- Boston Children's Hospital
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
- All patients will be admitted to the NICU, and having a post-menstrual age of >28 weeks. Participants will be divided into four groups according to the following criteria:
Group A
- Plan for major surgery anticipated to cause pain and agitation (i.e. esophageal atresia treatment);
- Patients who are anticipated to receive prolonged post-surgical neuromuscular blockade
Group B
- Plan for major surgery anticipated to cause pain and agitation (i.e. bowel surgery);
- Patients who are not anticipated to receive acute post-surgical neuromuscular blockade
Group C Plan for minor surgery anticipated to cause pain and agitation (i.e. hernia repair);
Group D No plan for surgery
Exclusion Criteria:
- Confirmed or suspected clinical seizures
- Metabolic abnormalities or inborn error of metabolism
- Skin abrasions or wounds located at the site of research sensor placement i.e. scalp, which interfere with the application of electrodes
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Modele obserwacyjne: Kohorta
- Perspektywy czasowe: Spodziewany
Kohorty i interwencje
Grupa / Kohorta |
Interwencja / Leczenie |
|---|---|
|
Group A
The following devices will be used in this Group: Waveguard (TM) EEG cap; Micro Movement Sensor; Pico Movement Sensor; QS Piezostimulator; tactileTM sensory evaluator. These subjects will also receive EMG monitoring. Subjects in this group will also have video recordings that may be used for novel analysis such as subdermal blood flow or micro-movement. |
The device is an EEG cap - a non-invasive EEG positioning system used to quickly place a large number of surface electrodes in a quick and consistent manner on the head.
The device will measure electrophysiological signals from the scalp at the time points in the study listed in the protocol.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor breathing and movement in children; the device is not used for validation purposes.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor respiration rate and gross body movement in children.
The device will not be used for validation purposes.
This device is not FDA approved.
This device is used for research purposes by neurologists and physiologists.
It is a mechanical tactile stimulator for use in functional imaging experiments like MEG, fMRI or EEG.
The stimulation is realized by using several different pin matrices.
In this study, the device is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
This device is not FDA approved.
This device is used for clinical and research purposes by neurologists and physiologists.
It is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
|
|
Group B
The following devices will be used in this Group: Waveguard (TM) EEG cap; Micro Movement Sensor; Pico Movement Sensor; QS Piezostimulator; tactileTM sensory evaluator. Subjects in this group will also have video recordings that may be used for novel analysis such as sub-dermal blood flow or micro-movement. |
The device is an EEG cap - a non-invasive EEG positioning system used to quickly place a large number of surface electrodes in a quick and consistent manner on the head.
The device will measure electrophysiological signals from the scalp at the time points in the study listed in the protocol.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor breathing and movement in children; the device is not used for validation purposes.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor respiration rate and gross body movement in children.
The device will not be used for validation purposes.
This device is not FDA approved.
This device is used for research purposes by neurologists and physiologists.
It is a mechanical tactile stimulator for use in functional imaging experiments like MEG, fMRI or EEG.
The stimulation is realized by using several different pin matrices.
In this study, the device is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
This device is not FDA approved.
This device is used for clinical and research purposes by neurologists and physiologists.
It is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
|
|
Group C
Plan for minor surgery anticipated to cause pain and agitation (i.e. hernia repair) The following devices will be used in this Group: Waveguard (TM) EEG cap; Micro Movement Sensor; Pico Movement Sensor; QS Piezostimulator; tactileTM sensory evaluator. Subjects in this group will also have video recordings that may be used for novel analysis such as sub-dermal blood flow or micro-movement. |
The device is an EEG cap - a non-invasive EEG positioning system used to quickly place a large number of surface electrodes in a quick and consistent manner on the head.
The device will measure electrophysiological signals from the scalp at the time points in the study listed in the protocol.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor breathing and movement in children; the device is not used for validation purposes.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor respiration rate and gross body movement in children.
The device will not be used for validation purposes.
This device is not FDA approved.
This device is used for research purposes by neurologists and physiologists.
It is a mechanical tactile stimulator for use in functional imaging experiments like MEG, fMRI or EEG.
The stimulation is realized by using several different pin matrices.
In this study, the device is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
This device is not FDA approved.
This device is used for clinical and research purposes by neurologists and physiologists.
It is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
|
|
Group D
No plan for surgery The following devices will be used in this Group: Waveguard (TM) EEG cap; Micro Movement Sensor; Pico Movement Sensor; QS Piezostimulator; tactileTM sensory evaluator. Subjects in this group will also have video recordings that may be used for novel analysis such as sub-dermal blood flow or micro-movement. |
The device is an EEG cap - a non-invasive EEG positioning system used to quickly place a large number of surface electrodes in a quick and consistent manner on the head.
The device will measure electrophysiological signals from the scalp at the time points in the study listed in the protocol.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor breathing and movement in children; the device is not used for validation purposes.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor respiration rate and gross body movement in children.
The device will not be used for validation purposes.
This device is not FDA approved.
This device is used for research purposes by neurologists and physiologists.
It is a mechanical tactile stimulator for use in functional imaging experiments like MEG, fMRI or EEG.
The stimulation is realized by using several different pin matrices.
In this study, the device is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
This device is not FDA approved.
This device is used for clinical and research purposes by neurologists and physiologists.
It is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Noxious Stimuli Results
Ramy czasowe: Up to 1 year
|
To assess pain-specific brain activity and autonomic responses post surgery in response to an acute noxious procedure in newborn infants admitted to the NICU. This outcome will be correlated with current behavioral and physiological based pain assessment tools as follows: Procedural-specific brain activity in infants with varying conditions with pre or post-operative pain. EEG: amplitude of noxious-event related potential evoked by a time-locked noxious stimulus. Pain-specific electro-dermal activity (EDA), electromyography (EMG) and subdermal skin flow; Pain-evoked behavioral measures including: Body movement; Eye squeeze, brow bulge and nasolabial furrow duration. Pain-evoked physiological measures including: Respiration rate; Heart rate; Blood pressure; Oxygen saturation; Observational pain scores (PIPP); EMG activity. |
Up to 1 year
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Resting State Results
Ramy czasowe: Up to 1 year
|
Characterize resting state activity in post-operative or control subjects as follows: Baseline brain (EEG) activity (power spectra of baseline EEG signal) in post operative or control subjects. Baseline EDA, EMG and subdermal skin flow; Baseline behavioral measures including: Presence of body movement, eye squeeze, brow bulge and nasolabial furrow. Baseline physiological measures including: Respiration rate; Heart rate; Blood pressure; Oxygen saturation; Observational pain scores (PIPP). The relationship with resting brain activity, electrodermal activity, behavior, physiological, and observational pain scores will be evaluated. |
Up to 1 year
|
Współpracownicy i badacze
Sponsor
Śledczy
- Główny śledczy: Laura Cornelissen, PhD, Boston Children's Hospital
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- IRB-P00022180
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .