Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

IRM intelligente accélérée pour les douleurs abdominales pédiatriques (IA-MRI)

28 septembre 2026 mis à jour par: Yaqi Shen,MD,PhD

Étude d'application prospective de l'imagerie de résonance magnétique accélérée intelligente chez les enfants souffrant de douleurs abdominales

The goal of this observational study is to evaluate the effectiveness of an intelligent accelerated MRI technique in children with abdominal pain. The main question it aims to answer is:

Does the intelligent accelerated MRI reduce scan time while maintaining diagnostic accuracy in pediatric patients?

Participants will:

Receive an abdominal MRI scan using the accelerated protocol as part of their clinical evaluation.

Have their scan duration and image quality compared to conventional MRI standards.

Aperçu de l'étude

Statut

Inscription sur invitation

Intervention / Traitement

Description détaillée

The goal of this prospective observational study is to evaluate the effectiveness and feasibility of an intelligent accelerated MRI scanning technique in pediatric patients presenting with abdominal pain. The main questions it aims to answer are:

Can the intelligent accelerated MRI technique achieve comparable or superior image quality to conventional MRI while significantly reducing scan time?

Does the accelerated scanning protocol reduce motion artifacts and improve diagnostic accuracy in pediatric patients?

Participants will:

Undergo an intelligent accelerated MRI scan of the abdomen as part of their diagnostic workup.

Have their scan duration, image quality, and diagnostic outcomes compared to historical or conventional MRI data (if available).

Why this study? Abdominal pain is a common pediatric complaint with diverse causes. While MRI is a non-invasive, radiation-free diagnostic tool, its utility in children is limited by long scan times and motion artifacts. This study investigates a novel intelligent accelerated MRI sequence that promises faster scans without compromising quality. Validating this technology in children could transform MRI's role in diagnosing abdominal pain by improving patient comfort, reducing sedation needs, and enhancing diagnostic accuracy.

Ethical approval: Conducted at Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, with oversight by the Institutional Ethics Committee.

Key innovation: Leveraging cutting-edge AI-driven acceleration to address pediatric imaging challenges. If successful, this approach could set a new standard for rapid, child-friendly MRI diagnostics.

Type d'étude

Observationnel

Inscription (Estimé)

150

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Hubei
      • Wuhan, Hubei, Chine, 430030
        • Tongji Hospital

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

3 ans à 18 ans (Enfant, Adulte)

Accepte les volontaires sains

Oui

Sexes éligibles pour l'étude

Tout

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

The study population consists of pediatric patients aged 3-18 years presenting with abdominal pain who have undergone a prior abdominal CT examination as part of their clinical evaluation. Eligible participants must have guardians who voluntarily consent to an additional MRI scan and provide written informed consent.

La description

Inclusion Criteria:

  • Children aged 3-18 years presenting with abdominal pain who have undergone abdominal CT examination.
  • Children whose guardians voluntarily agree to MRI examination and sign written informed consent.

Exclusion Criteria:

  • Children with contraindications to MRI (e.g., metal implants, severe claustrophobia) or those unable to cooperate with the examination.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Modèles d'observation: COHORT
  • Perspectives temporelles: PROSPECTIVE

Cohortes et interventions

Groupe / Cohorte
Intervention / Traitement
1

Pediatric patients who were undergoing MRE examination for abdominal pain

All patients underwent MRI scans of the abdominal and pelvic regions on the uMR 790 scanner at Tongji Hospital's Optical Valley Campus. The scanning protocol included multiplanar ACS T2WI sequences, TACS T2WI sequences, and conventional T2WI sequences.

ACS T2WI sequence: Used for preliminary motion artifact correction. TACS T2WI sequence: Employed for advanced motion artifact correction and provided dynamic images of organ movement.

Conventional T2WI sequence: Served as the standard reference for comparison.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Scan Time Reduction with Intelligent Accelerated MRI
Délai: During MRI scan procedure (single time point).

Comparison of total scan time (minutes) for abdominal/pelvic MRI using the intelligent accelerated protocol (ACS-T2WI and TACS-T2WI sequences) versus conventional T2WI sequences, while maintaining diagnostic image quality (assessed by radiologists using a 5-point Likert scale).

During MRI scan procedure (single time point).

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Diagnostic Accuracy of Accelerated MRI
Délai: Within 24 hours post-scan.

Diagnostic concordance rate (%) between intelligent accelerated MRI and conventional MRI for identifying causes of abdominal pain (e.g., appendicitis, bowel obstruction), validated against final clinical/histopathological diagnoses.

Within 24 hours post-scan.
Motion Artifact Reduction
Délai: During MRI scan procedure (single time point).

Quantitative evaluation of motion artifacts in accelerated MRI scans (ACS-T2WI and TACS-T2WI) compared to conventional T2WI, scored by two blinded radiologists using a 4-point scale (1 = severe artifacts; 4 = minimal/no artifacts).

During MRI scan procedure (single time point).

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Publications générales

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

30 octobre 2024

Achèvement primaire (Estimé)

31 décembre 2026

Achèvement de l'étude (Estimé)

31 décembre 2027

Dates d'inscription aux études

Première soumission

2 septembre 2025

Première soumission répondant aux critères de contrôle qualité

9 septembre 2025

Première publication (Réel)

10 septembre 2025

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

29 septembre 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

28 septembre 2026

Dernière vérification

1 octobre 2025

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • TJ-IRB202410027
  • 82471969 (Autre subvention/numéro de financement: National Natural Science Foundation of China (NSFC))

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

INDÉCIS

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner