- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07568392
Arthroscopic Rotator Cuff Repair Trial
30 avril 2026 mis à jour par: Joseph W. Galvin
A Prospective Randomized Controlled Trial Comparing Arthroscopic Rotator Cuff Repair With and Without Biceps Tendon Autograft Patch Augmentation
This study aims to assess post-operative outcomes and healing rates following arthroscopic rotator cuff repair with and without biceps tendon autograft patch augmentation in patients with medium to large rotator cuff tears.
This will be a single center, parallel arm randomized trial within the Orthopedics Shoulder Surgery Department at University of Iowa Hospitals and Clinics (UIHC).
Eligible patients indicated for arthroscopic rotator cuff repair and open subpectoral biceps tenodesis will be enrolled, consented and randomized, in a 1:1 scheme, into 2 study arms.
Arm 1 will consist of arthroscopic rotator cuff repair without biceps tendon autograft.
Arm 2 will consist of arthroscopic rotator cuff repair with biceps tendon autograft patch augmentation.
Outcomes of interest are American Shoulder and Elbow Surgeons Score (ASES), at 1 year and 2 years postoperatively.
Exploratory outcomes are SANE, VAS Pain and active shoulder range of motion, and healing signs on MRI imaging studies at minimum 6-months postoperatively.
Aperçu de l'étude
Statut
Pas encore de recrutement
Les conditions
Description détaillée
Rotator cuff tears are common causes of shoulder pain, and it is a highly prevalent condition among a variety of ages.
Treatment options for rotator cuff tears include nonsurgical and surgical options.
Surgical repair of rotator cuff tears is a widely accepted treatment option; however, re-tear rates are concerning and a frequent complication.
Published studies suggest failure rates ranging from 11-94%.
Different surgical techniques have been designed to address this potential complication, such as patch augmentation.
Recently, patch augmentation with biceps tendon autograft has been utilized as a cost-effective approach.
Therefore, the purpose of this study is to evaluate and compare post-operative outcomes and tendon healing rates after rotator cuff repairs with and without patch augmentation with biceps tendon.
This study aims to assess post-operative outcomes and healing rates following arthroscopic rotator cuff repair with and without biceps tendon autograft patch augmentation in patients with medium to large rotator cuff tears.
Both surgical techniques are standard of care procedures performed routinely at University of Iowa Health Care.
This will be a single center, parallel arm randomized trial within the Orthopedics Shoulder Surgery Department at University of Iowa Hospitals and Clinics (UIHC).
Eligible patients indicated for arthroscopic rotator cuff repair and open subpectoral biceps tenodesis will be enrolled, consented and randomized, in a 1:1 scheme, into 2 study arms.
Arm 1 will consist of arthroscopic rotator cuff repair without biceps tendon autograft.
Arm 2 will consist of arthroscopic rotator cuff repair with biceps tendon autograft.
Outcomes of interest are American Shoulder and Elbow Surgeons Score (ASES), at 1 year and 2 years postoperatively.
Exploratory outcomes are SANE, VAS Pain and active range of motion, and healing signs on imaging studies at minimum 6-months postoperatively.
Participants in both arms will undergo a shoulder MRI without contrast at 6 months post-operatively.
This MRI is the same type of MRI perform as diagnosis or control as standard of care practices.
Type d'étude
Interventionnel
Inscription (Estimé)
80
Phase
- N'est pas applicable
Contacts et emplacements
Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.
Coordonnées de l'étude
- Nom: Joseph Galvin, Other, MD
- Numéro de téléphone: 3193848378
- E-mail: joseph-galvin@uiowa.edu
Critères de participation
Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
Non
La description
Inclusion Criteria:
- Patients > 18 years of age who speak English, indicated for arthroscopic rotator cuff repair and open subpectoral biceps tenodesis.
- Supraspinatus (+/- anterior infraspinatus tendon) full thickness tears.
- Medium (1-3cm) and large (3-5) cm tears. Classification according to anterior to posterior dimensions: small <1cm, medium 1-3 cm, large 3-5 cm, massive >5cm or 2 tendons.
- Patte Grade 1 and 2. Patte Classification: grade 1, tear at insertion; grade 2, retracted to humeral head; grade 3, retracted to glenoid or medial to glenoid.
- Goutallier grade 0-2 fatty infiltration on pre-operative MRI.
- Repairable upper border subscapularis tendon tear.
- Patients undergoing concomitant biceps tenodesis.
Exclusion Criteria:
- Pregnant women, non-English speakers and prisoners.
- Patients with prior surgery on the ipsilateral shoulder.
- Worker's compensation status.
- Adhesive capsulitis.
- Patient with glenohumeral osteoarthritis, as graded by the modified Samilson and Prieto Classification (grades 1-3).
- Partial thickness rotator cuff tears.
- Any cuff tears requiring medialization of the footprint
- Patients undergoing concomitant distal clavicle resection.
Plan d'étude
Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Double
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Comparateur actif: Cuff repair without patch autograft
Arthroscopic rotator cuff repair without patch augmentation
|
Standard of care technique.
Active comparator
|
|
Expérimental: Cuff repair with patch augmentation
Arthroscopic rotator cuff repair with patch augmentation
|
This is a standard of care practice surgical technique.
This arm will undergo arthroscopic rotator cuff repair with the use of called "Biceps Smash" technique which may provide improved tendon thickness and biology with limited morbidity and in a cost effective approach
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
ASES Score
Délai: 1 year post-operative
|
American Shoulder and Elbow Surgeons Score.
From 0-100.
Higher is better
|
1 year post-operative
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Rotator cuff healing
Délai: 6 months post-operative
|
Signs of cuff healing in MRI
|
6 months post-operative
|
Autres mesures de résultats
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
SANE Score
Délai: 1 year post-operative
|
From 0-100, how good the shoulder feels.
Higher is better
|
1 year post-operative
|
|
VAS Pain Score
Délai: 1 year post-operative
|
0-10. Higher is worse
|
1 year post-operative
|
|
ROM
Délai: 1 year post-operative
|
Range of motion
|
1 year post-operative
|
Collaborateurs et enquêteurs
C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.
Parrainer
Dates d'enregistrement des études
Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.
Dates principales de l'étude
Début de l'étude (Estimé)
1 juin 2026
Achèvement primaire (Estimé)
30 juin 2027
Achèvement de l'étude (Estimé)
30 septembre 2027
Dates d'inscription aux études
Première soumission
7 avril 2026
Première soumission répondant aux critères de contrôle qualité
30 avril 2026
Première publication (Réel)
5 mai 2026
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
5 mai 2026
Dernière mise à jour soumise répondant aux critères de contrôle qualité
30 avril 2026
Dernière vérification
1 avril 2026
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- 202512509
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Non
Étudie un produit d'appareil réglementé par la FDA américaine
Non
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .