Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Arthroscopic Rotator Cuff Repair Trial

30 avril 2026 mis à jour par: Joseph W. Galvin

A Prospective Randomized Controlled Trial Comparing Arthroscopic Rotator Cuff Repair With and Without Biceps Tendon Autograft Patch Augmentation

This study aims to assess post-operative outcomes and healing rates following arthroscopic rotator cuff repair with and without biceps tendon autograft patch augmentation in patients with medium to large rotator cuff tears. This will be a single center, parallel arm randomized trial within the Orthopedics Shoulder Surgery Department at University of Iowa Hospitals and Clinics (UIHC). Eligible patients indicated for arthroscopic rotator cuff repair and open subpectoral biceps tenodesis will be enrolled, consented and randomized, in a 1:1 scheme, into 2 study arms. Arm 1 will consist of arthroscopic rotator cuff repair without biceps tendon autograft. Arm 2 will consist of arthroscopic rotator cuff repair with biceps tendon autograft patch augmentation. Outcomes of interest are American Shoulder and Elbow Surgeons Score (ASES), at 1 year and 2 years postoperatively. Exploratory outcomes are SANE, VAS Pain and active shoulder range of motion, and healing signs on MRI imaging studies at minimum 6-months postoperatively.

Aperçu de l'étude

Description détaillée

Rotator cuff tears are common causes of shoulder pain, and it is a highly prevalent condition among a variety of ages. Treatment options for rotator cuff tears include nonsurgical and surgical options. Surgical repair of rotator cuff tears is a widely accepted treatment option; however, re-tear rates are concerning and a frequent complication. Published studies suggest failure rates ranging from 11-94%. Different surgical techniques have been designed to address this potential complication, such as patch augmentation. Recently, patch augmentation with biceps tendon autograft has been utilized as a cost-effective approach. Therefore, the purpose of this study is to evaluate and compare post-operative outcomes and tendon healing rates after rotator cuff repairs with and without patch augmentation with biceps tendon. This study aims to assess post-operative outcomes and healing rates following arthroscopic rotator cuff repair with and without biceps tendon autograft patch augmentation in patients with medium to large rotator cuff tears. Both surgical techniques are standard of care procedures performed routinely at University of Iowa Health Care. This will be a single center, parallel arm randomized trial within the Orthopedics Shoulder Surgery Department at University of Iowa Hospitals and Clinics (UIHC). Eligible patients indicated for arthroscopic rotator cuff repair and open subpectoral biceps tenodesis will be enrolled, consented and randomized, in a 1:1 scheme, into 2 study arms. Arm 1 will consist of arthroscopic rotator cuff repair without biceps tendon autograft. Arm 2 will consist of arthroscopic rotator cuff repair with biceps tendon autograft. Outcomes of interest are American Shoulder and Elbow Surgeons Score (ASES), at 1 year and 2 years postoperatively. Exploratory outcomes are SANE, VAS Pain and active range of motion, and healing signs on imaging studies at minimum 6-months postoperatively. Participants in both arms will undergo a shoulder MRI without contrast at 6 months post-operatively. This MRI is the same type of MRI perform as diagnosis or control as standard of care practices.

Type d'étude

Interventionnel

Inscription (Estimé)

80

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Non

La description

Inclusion Criteria:

  • Patients > 18 years of age who speak English, indicated for arthroscopic rotator cuff repair and open subpectoral biceps tenodesis.
  • Supraspinatus (+/- anterior infraspinatus tendon) full thickness tears.
  • Medium (1-3cm) and large (3-5) cm tears. Classification according to anterior to posterior dimensions: small <1cm, medium 1-3 cm, large 3-5 cm, massive >5cm or 2 tendons.
  • Patte Grade 1 and 2. Patte Classification: grade 1, tear at insertion; grade 2, retracted to humeral head; grade 3, retracted to glenoid or medial to glenoid.
  • Goutallier grade 0-2 fatty infiltration on pre-operative MRI.
  • Repairable upper border subscapularis tendon tear.
  • Patients undergoing concomitant biceps tenodesis.

Exclusion Criteria:

  • Pregnant women, non-English speakers and prisoners.
  • Patients with prior surgery on the ipsilateral shoulder.
  • Worker's compensation status.
  • Adhesive capsulitis.
  • Patient with glenohumeral osteoarthritis, as graded by the modified Samilson and Prieto Classification (grades 1-3).
  • Partial thickness rotator cuff tears.
  • Any cuff tears requiring medialization of the footprint
  • Patients undergoing concomitant distal clavicle resection.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Double

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Comparateur actif: Cuff repair without patch autograft
Arthroscopic rotator cuff repair without patch augmentation
Standard of care technique. Active comparator
Expérimental: Cuff repair with patch augmentation
Arthroscopic rotator cuff repair with patch augmentation
This is a standard of care practice surgical technique. This arm will undergo arthroscopic rotator cuff repair with the use of called "Biceps Smash" technique which may provide improved tendon thickness and biology with limited morbidity and in a cost effective approach

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
ASES Score
Délai: 1 year post-operative
American Shoulder and Elbow Surgeons Score. From 0-100. Higher is better
1 year post-operative

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Rotator cuff healing
Délai: 6 months post-operative
Signs of cuff healing in MRI
6 months post-operative

Autres mesures de résultats

Mesure des résultats
Description de la mesure
Délai
SANE Score
Délai: 1 year post-operative
From 0-100, how good the shoulder feels. Higher is better
1 year post-operative
VAS Pain Score
Délai: 1 year post-operative
0-10. Higher is worse
1 year post-operative
ROM
Délai: 1 year post-operative
Range of motion
1 year post-operative

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Estimé)

1 juin 2026

Achèvement primaire (Estimé)

30 juin 2027

Achèvement de l'étude (Estimé)

30 septembre 2027

Dates d'inscription aux études

Première soumission

7 avril 2026

Première soumission répondant aux critères de contrôle qualité

30 avril 2026

Première publication (Réel)

5 mai 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

5 mai 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

30 avril 2026

Dernière vérification

1 avril 2026

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • 202512509

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner