Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Arthroscopic Rotator Cuff Repair Trial

30 de abril de 2026 atualizado por: Joseph W. Galvin

A Prospective Randomized Controlled Trial Comparing Arthroscopic Rotator Cuff Repair With and Without Biceps Tendon Autograft Patch Augmentation

This study aims to assess post-operative outcomes and healing rates following arthroscopic rotator cuff repair with and without biceps tendon autograft patch augmentation in patients with medium to large rotator cuff tears. This will be a single center, parallel arm randomized trial within the Orthopedics Shoulder Surgery Department at University of Iowa Hospitals and Clinics (UIHC). Eligible patients indicated for arthroscopic rotator cuff repair and open subpectoral biceps tenodesis will be enrolled, consented and randomized, in a 1:1 scheme, into 2 study arms. Arm 1 will consist of arthroscopic rotator cuff repair without biceps tendon autograft. Arm 2 will consist of arthroscopic rotator cuff repair with biceps tendon autograft patch augmentation. Outcomes of interest are American Shoulder and Elbow Surgeons Score (ASES), at 1 year and 2 years postoperatively. Exploratory outcomes are SANE, VAS Pain and active shoulder range of motion, and healing signs on MRI imaging studies at minimum 6-months postoperatively.

Visão geral do estudo

Descrição detalhada

Rotator cuff tears are common causes of shoulder pain, and it is a highly prevalent condition among a variety of ages. Treatment options for rotator cuff tears include nonsurgical and surgical options. Surgical repair of rotator cuff tears is a widely accepted treatment option; however, re-tear rates are concerning and a frequent complication. Published studies suggest failure rates ranging from 11-94%. Different surgical techniques have been designed to address this potential complication, such as patch augmentation. Recently, patch augmentation with biceps tendon autograft has been utilized as a cost-effective approach. Therefore, the purpose of this study is to evaluate and compare post-operative outcomes and tendon healing rates after rotator cuff repairs with and without patch augmentation with biceps tendon. This study aims to assess post-operative outcomes and healing rates following arthroscopic rotator cuff repair with and without biceps tendon autograft patch augmentation in patients with medium to large rotator cuff tears. Both surgical techniques are standard of care procedures performed routinely at University of Iowa Health Care. This will be a single center, parallel arm randomized trial within the Orthopedics Shoulder Surgery Department at University of Iowa Hospitals and Clinics (UIHC). Eligible patients indicated for arthroscopic rotator cuff repair and open subpectoral biceps tenodesis will be enrolled, consented and randomized, in a 1:1 scheme, into 2 study arms. Arm 1 will consist of arthroscopic rotator cuff repair without biceps tendon autograft. Arm 2 will consist of arthroscopic rotator cuff repair with biceps tendon autograft. Outcomes of interest are American Shoulder and Elbow Surgeons Score (ASES), at 1 year and 2 years postoperatively. Exploratory outcomes are SANE, VAS Pain and active range of motion, and healing signs on imaging studies at minimum 6-months postoperatively. Participants in both arms will undergo a shoulder MRI without contrast at 6 months post-operatively. This MRI is the same type of MRI perform as diagnosis or control as standard of care practices.

Tipo de estudo

Intervencional

Inscrição (Estimado)

80

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Não

Descrição

Inclusion Criteria:

  • Patients > 18 years of age who speak English, indicated for arthroscopic rotator cuff repair and open subpectoral biceps tenodesis.
  • Supraspinatus (+/- anterior infraspinatus tendon) full thickness tears.
  • Medium (1-3cm) and large (3-5) cm tears. Classification according to anterior to posterior dimensions: small <1cm, medium 1-3 cm, large 3-5 cm, massive >5cm or 2 tendons.
  • Patte Grade 1 and 2. Patte Classification: grade 1, tear at insertion; grade 2, retracted to humeral head; grade 3, retracted to glenoid or medial to glenoid.
  • Goutallier grade 0-2 fatty infiltration on pre-operative MRI.
  • Repairable upper border subscapularis tendon tear.
  • Patients undergoing concomitant biceps tenodesis.

Exclusion Criteria:

  • Pregnant women, non-English speakers and prisoners.
  • Patients with prior surgery on the ipsilateral shoulder.
  • Worker's compensation status.
  • Adhesive capsulitis.
  • Patient with glenohumeral osteoarthritis, as graded by the modified Samilson and Prieto Classification (grades 1-3).
  • Partial thickness rotator cuff tears.
  • Any cuff tears requiring medialization of the footprint
  • Patients undergoing concomitant distal clavicle resection.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Dobro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Comparador Ativo: Cuff repair without patch autograft
Arthroscopic rotator cuff repair without patch augmentation
Standard of care technique. Active comparator
Experimental: Cuff repair with patch augmentation
Arthroscopic rotator cuff repair with patch augmentation
This is a standard of care practice surgical technique. This arm will undergo arthroscopic rotator cuff repair with the use of called "Biceps Smash" technique which may provide improved tendon thickness and biology with limited morbidity and in a cost effective approach

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
ASES Score
Prazo: 1 year post-operative
American Shoulder and Elbow Surgeons Score. From 0-100. Higher is better
1 year post-operative

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Rotator cuff healing
Prazo: 6 months post-operative
Signs of cuff healing in MRI
6 months post-operative

Outras medidas de resultado

Medida de resultado
Descrição da medida
Prazo
SANE Score
Prazo: 1 year post-operative
From 0-100, how good the shoulder feels. Higher is better
1 year post-operative
VAS Pain Score
Prazo: 1 year post-operative
0-10. Higher is worse
1 year post-operative
ROM
Prazo: 1 year post-operative
Range of motion
1 year post-operative

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Estimado)

1 de junho de 2026

Conclusão Primária (Estimado)

30 de junho de 2027

Conclusão do estudo (Estimado)

30 de setembro de 2027

Datas de inscrição no estudo

Enviado pela primeira vez

7 de abril de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

30 de abril de 2026

Primeira postagem (Real)

5 de maio de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

5 de maio de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

30 de abril de 2026

Última verificação

1 de abril de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • 202512509

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever