Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Assessment of Pulmonary Perfusion and Hemodynamic Measurements by Electrical Impedance Tomography in Patients Undergoing Pulmonary Thromboendarterectomy.

4 mai 2026 mis à jour par: University of Sao Paulo General Hospital

Chronic thromboembolic pulmonary hypertension (CTEPH) is a condition in which old blood clots block the blood vessels in the lungs, making it harder for the heart to pump blood through the lungs. Surgery called pulmonary thromboendarterectomy can remove these clots and improve blood flow, but doctors need reliable ways to evaluate lung blood flow before and after surgery.

This study will evaluate a bedside imaging method called electrical impedance tomography (EIT), which can measure how blood flows through different regions of the lungs without radiation or invasive procedures. Patients undergoing surgery for CTEPH will be monitored with EIT before and after surgery, and the results will be compared with standard lung perfusion imaging.

The goal of this study is to determine whether EIT can provide useful information about lung blood flow and changes after surgery, and whether it could serve as a complementary bedside tool to help monitor patients with CTEPH.

Aperçu de l'étude

Description détaillée

Chronic thromboembolic pulmonary hypertension (CTEPH) results from persistent obstruction of the pulmonary arteries by organized thromboembolic material and is a potentially curable cause of pulmonary hypertension. Pulmonary thromboendarterectomy is the treatment of choice for eligible patients and leads to significant improvement in pulmonary perfusion and hemodynamics.

Assessment of regional pulmonary perfusion is essential in the management of CTEPH. While perfusion SPECT/CT is commonly used for this purpose, it cannot be performed at the bedside and involves exposure to ionizing radiation. Electrical impedance tomography (EIT) is a non-invasive, radiation-free imaging technique that allows bedside assessment of lung ventilation and pulmonary perfusion through analysis of pulsatility-related impedance changes.

In this prospective diagnostic study, pulmonary perfusion assessed by EIT will be evaluated in patients undergoing pulmonary thromboendarterectomy and compared with perfusion SPECT/CT. EIT measurements will be obtained in the perioperative period, and perfusion changes will be analyzed using quantitative indices derived from impedance signals. The study focuses on the feasibility and performance of EIT as a bedside method for assessing pulmonary perfusion changes associated with surgical treatment of CTEPH.

Type d'étude

Interventionnel

Inscription (Estimé)

36

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

Sauvegarde des contacts de l'étude

  • Nom: Jaomar JC Salazar, MD
  • Numéro de téléphone: +5511966477244
  • E-mail: jaomar@usp.br

Lieux d'étude

    • São Paulo
      • São Paulo, São Paulo, Brésil, 05403-900
        • Recrutement
        • Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da USP
        • Contact:
        • Contact:
          • Jaomar JC Salazar, MD
          • Numéro de téléphone: +5511966477244
          • E-mail: jaomar@usp.br

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Non

La description

Inclusion Criteria:

- Patients diagnosed with chronic thromboembolic pulmonary hypertension (CTEPH) followed at the Pulmonology Service of InCor-HCFMUSP and scheduled for pulmonary thromboendarterectomy at InCor-FMUSP.

Exclusion Criteria:

  • Age under 18 years
  • Pregnancy
  • Structural heart disease (atrial septal defect, ventricular septal defect, or valvular heart disease)
  • Cardiac arrhythmias
  • Use of a cardiac pacemaker or other implantable electronic device
  • Skin lesions on the thoracic region at the site of EIT electrode belt placement
  • Absence of central venous access on the day of the preoperative protocol evaluation
  • Difficulty understanding the procedures to be performed
  • Refusal to participate in the study (non-signing of the Informed Consent Form)
  • Refusal by the attending medical team

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Diagnostique
  • Répartition: N / A
  • Modèle interventionnel: Affectation à un seul groupe
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Diagnostic Imaging Ar.
Patients with chronic thromboembolic pulmonary hypertension undergoing pulmonary thromboendarterectomy will be evaluated using electrical impedance tomography (EIT) for assessment of regional pulmonary perfusion in the preoperative and postoperative periods. EIT-derived perfusion indices will be analyzed and compared with imaging-based thrombus burden and pulmonary perfusion assessed by SPECT-CT.
Non-invasive, radiation-free bedside assessment of pulmonary perfusion using Electrical Impedance Tomography (EIT). EIT will be performed using the Enlight 2100 system (Timpel Medical®, Brazil) in the preoperative and postoperative periods of pulmonary thromboendarterectomy. Pulmonary perfusion will be assessed through analysis of pulsatility signals and first-pass kinetics following hypertonic saline bolus injection, generating regional perfusion maps and quantitative indices, including the wasted ventilatory index. Data will be analyzed offline.
Pulmonary perfusion assessment performed using single-photon emission computed tomography (SPECT) with technetium-99m-labeled macroaggregated albumin, fused with non-contrast chest computed tomography (CT) acquired during both inspiratory and expiratory phases. The fusion of functional perfusion images from SPECT with anatomical images from CT allows regional assessment of pulmonary perfusion and thromboembolic burden. This examination will be performed in the preoperative period and during postoperative follow-up and will serve as a reference imaging modality for comparison with Electrical Impedance Tomography-derived perfusion measures.
Pulmonary thromboendarterectomy performed according to standard institutional clinical practice for the treatment of chronic thromboembolic pulmonary hypertension. This surgical procedure is conducted solely for clinical indication and is not investigational. Imaging and monitoring assessments included in this study do not alter the surgical technique or perioperative clinical management.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Evaluation of perfusion maps obtained by Electrical Impedance Tomography (EIT) in the pre- and postoperative period using the wasted ventilation index..
Délai: From the preoperative period to the immediate postoperative period during intensive care unit stay (on the day of surgery).
Change in pulmonary perfusion assessed by Electrical Impedance Tomography (EIT) using the Enlight 2100 system (Timpel Medical®, Brazil), quantified by the wasted ventilatory index derived from regional perfusion maps, comparing preoperative and postoperative measurements in patients undergoing pulmonary thromboendarterectomy.
From the preoperative period to the immediate postoperative period during intensive care unit stay (on the day of surgery).

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Comparison of pulmonary perfusion assessed by Electrical Impedance Tomography and SPECT-CT.
Délai: From the preoperative period to the postoperative follow-up (up to 6 months after surgery).
Comparison of changes in regional pulmonary perfusion assessed by Electrical Impedance Tomography (EIT) and by SPECT-CT imaging, expressed as percentage variation between preoperative and postoperative evaluations in patients undergoing pulmonary thromboendarterectomy.
From the preoperative period to the postoperative follow-up (up to 6 months after surgery).
Incidence of adverse events related to Electrical Impedance Tomography perfusion assessment.
Délai: From the preoperative period to hospital discharge, up to approximately 30 days
Incidence and type of adverse events related to pulmonary perfusion assessment using Electrical Impedance Tomography, including events associated with the use of hypertonic saline injection.
From the preoperative period to hospital discharge, up to approximately 30 days

Autres mesures de résultats

Mesure des résultats
Description de la mesure
Délai
Quality of life assessed by SF-36 questionnaire after pulmonary thromboendarterectomy.
Délai: Up to 6 months after surgery.
Quality of life assessed using the Short Form-36 (SF-36) questionnaire during outpatient follow-up after pulmonary thromboendarterectomy. Scores range from 0 to 100, where higher scores indicate better quality of life.
Up to 6 months after surgery.
Correlation between EIT-derived pulsatility and hemodynamic parameter.
Délai: From the preoperative period to the immediate postoperative period (during intensive care unit stay).
Correlation between changes in pulsatility (ΔZsys) assessed by Electrical Impedance Tomography and hemodynamic parameters, including stroke volume, cardiac output, and mean pulmonary artery pressure, measured using thermodilution via pulmonary artery catheter.
From the preoperative period to the immediate postoperative period (during intensive care unit stay).
Change in plasma sodium concentration after hypertonic saline injection
Délai: From baseline (before saline injection) to up to 2 hours after injection during hospitalization.
Change in plasma sodium concentration measured before and after hypertonic saline injection used for Electrical Impedance Tomography perfusion assessment, expressed in mEq/L.
From baseline (before saline injection) to up to 2 hours after injection during hospitalization.

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Publications générales

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

25 février 2025

Achèvement primaire (Estimé)

1 décembre 2026

Achèvement de l'étude (Estimé)

1 décembre 2026

Dates d'inscription aux études

Première soumission

10 février 2026

Première soumission répondant aux critères de contrôle qualité

4 mai 2026

Première publication (Réel)

11 mai 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

11 mai 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

4 mai 2026

Dernière vérification

1 mai 2026

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner