- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07637695
Silicone Barrier Spray Versus Zinc Oxide Ointment for Incontinence-Associated Dermatitis
Effectiveness of Structured Skin Care Using Silicone Barrier Spray Compared With Zinc Oxide Ointment for Incontinence-Associated Dermatitis in Long-Term Care Residents: A Randomized Controlled Trial
Incontinence-associated dermatitis (IAD) is a common skin condition among long-term care residents and is caused by prolonged exposure to urine or feces. IAD can lead to skin irritation, discomfort, impaired skin integrity, and an increased risk of secondary complications. Structured skin care, including cleansing and barrier protection, is recommended for the prevention and management of IAD.
This randomized controlled trial evaluated the effectiveness of a silicone barrier spray compared with zinc oxide ointment as part of a structured skin care program for residents with mild IAD in a long-term care facility. Participants were randomly assigned to receive either silicone barrier spray or zinc oxide ointment following routine skin cleansing. Clinical severity of IAD and skin barrier function were assessed at baseline, Day 7, and Day 14 using standardized clinical and biophysical measurements, including IAD severity score, skin hydration, transepidermal water loss, skin pH, and skin temperature. The study aimed to determine whether silicone barrier spray provides comparable or improved outcomes compared with conventional zinc oxide ointment in the management of mild IAD.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Incontinence-associated dermatitis (IAD) is a common form of moisture-associated skin damage resulting from prolonged exposure of the skin to urine and/or feces. The condition is particularly prevalent among residents of long-term care facilities because of advanced age, reduced mobility, cognitive impairment, chronic illness, and urinary or fecal incontinence. IAD is associated with erythema, discomfort, pain, impaired skin barrier function, and an increased risk of secondary complications, including pressure injuries and skin infections.
Maintenance of skin barrier integrity is a fundamental component of IAD prevention and treatment. Current international guidelines recommend structured skin care programs consisting of routine cleansing, moisturization, and barrier protection. Zinc oxide-based ointments are among the most commonly used barrier products because they provide effective protection against moisture and irritants. However, zinc oxide formulations may be difficult to apply and remove, can leave residue on the skin, and may increase friction during repeated cleansing procedures.
Silicone-based barrier films represent an alternative approach to skin protection. These products form a transparent, breathable, water-resistant layer on the skin surface and may reduce friction while preserving epidermal barrier function. Sprayable silicone barrier formulations may provide additional practical advantages, including rapid application, uniform coverage, reduced physical contact with damaged skin, and improved ease of use for caregivers. Such characteristics may be particularly valuable in long-term care settings where frequent skin care interventions are required.
Despite increasing clinical use of silicone-based barrier products, direct randomized comparisons between sprayable silicone barrier films and traditional zinc oxide ointments remain limited. Furthermore, objective evaluations of skin barrier recovery using biophysical measurements have not been extensively investigated in long-term care populations with IAD.
The purpose of this study was to compare the effectiveness of a silicone barrier spray and zinc oxide ointment when incorporated into a structured skin care program for long-term care residents with mild incontinence-associated dermatitis. In addition to evaluating clinical improvement, the study investigated changes in skin barrier function using objective biophysical assessments. The findings of this study are intended to provide evidence to support clinical decision-making regarding barrier protection strategies and to improve skin care practices for vulnerable older adults residing in long-term care facilities.
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
Taoyuan City
-
Longtan, Taoyuan City, Taïwan, 325
- Taoyuan Armed Forces General Hospital
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Enfant
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
La description
Inclusion Criteria:
- Resident of a long-term care facility.
- Diagnosis of mild incontinence-associated dermatitis (IAD), classified as GLOBIAD Category 1.
- Ability to provide informed consent personally or through a legally authorized representative.
- Willingness to participate in the study and comply with study procedures.
Exclusion Criteria:
- Incontinence-associated dermatitis (IAD) classified as GLOBIAD Category 2.
- Presence of skin erosion, skin loss, open wounds, or active skin infection in the assessment area.
- Known allergy or hypersensitivity to silicone-based barrier products or zinc oxide preparations.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Seul
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Silicone Barrier Spray
Participants received a silicone-based barrier spray after structured skin cleansing and moisturizing care throughout the 14-day study period.
|
A silicone-based skin barrier spray (Brava® Skin Barrier Spray, Coloplast A/S, Denmark) was applied to the perineal skin after each cleansing episode as part of a structured skin care regimen.
The spray forms a transparent, breathable, water-resistant protective film designed to reduce moisture-related skin damage and friction while maintaining skin barrier integrity.
Participants received the intervention throughout the 14-day study period following routine cleansing and moisturizing care.
|
|
Comparateur actif: Zinc Oxide Ointment
Participants received zinc oxide ointment after structured skin cleansing and moisturizing care throughout the 14-day study period.
|
A traditional zinc oxide-based barrier ointment applied to the perineal skin after routine cleansing and moisturizing care.
The ointment forms a protective barrier that helps reduce skin exposure to moisture, irritants, and friction associated with urinary and fecal incontinence.
The intervention was administered as part of a structured skin care protocol throughout the 14-day study period.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Change in Incontinence-Associated Dermatitis Severity Score
Délai: Baseline (Day 1), Day 7, and Day 14
|
Clinical severity of incontinence-associated dermatitis assessed using the modified Ghent Global Incontinence-Associated Dermatitis Monitoring Tool (GLOBIAD-M).
Scores ranged from 0 (normal skin) to 2 (more severe dermatitis), with lower scores indicating improvement in skin condition.
|
Baseline (Day 1), Day 7, and Day 14
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Skin Hydration
Délai: Baseline (Day 1), Day 7, and Day 14
|
Skin hydration measured using stratum corneum capacitance at affected skin sites.
|
Baseline (Day 1), Day 7, and Day 14
|
|
Transepidermal Water Loss (TEWL)
Délai: Baseline (Day 1), Day 7, and Day 14
|
Skin barrier function assessed by measuring transepidermal water loss (g/m²/h) using a closed-chamber evaporimeter.
|
Baseline (Day 1), Day 7, and Day 14
|
|
Skin pH
Délai: Baseline (Day 1), Day 7, and Day 14
|
Skin surface pH measured at affected skin sites using a flat-surface electrode device.
|
Baseline (Day 1), Day 7, and Day 14
|
|
Skin Temperature
Délai: Baseline (Day 1), Day 7, and Day 14
|
Skin temperature measured at affected skin sites using a skin assessment device.
|
Baseline (Day 1), Day 7, and Day 14
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Po Jen Hsiao, MD, PhD, Taoyuan Armed Forces General Hospital
- Chaise d'étude: Hsieh Chih Tsai, PhD, National Taiwan University of Science and Technology
- Directeur d'études: Po Chung Chen, MD, MS, Taoyuan Armed Forces General Hospital
Publications et liens utiles
Publications générales
- Bernatchez SF, Mengistu GE, Ekholm BP, Sanghi S, Theiss SD. Reducing Friction on Skin at Risk: The Use of 3M Cavilon No Sting Barrier Film. Adv Wound Care (New Rochelle). 2015 Dec 1;4(12):705-710. doi: 10.1089/wound.2015.0628.
- Holroyd S, Graham K. Prevention and management of incontinence-associated dermatitis using a barrier cream. Br J Community Nurs. 2014 Dec;Suppl Wound Care:S32-8. doi: 10.12968/bjcn.2014.19.Sup6.S32.
- McNichol LL, Ayello EA, Phearman LA, Pezzella PA, Culver EA. Incontinence-Associated Dermatitis: State of the Science and Knowledge Translation. Adv Skin Wound Care. 2018 Nov;31(11):502-513. doi: 10.1097/01.ASW.0000546234.12260.61.
- Van den Bussche K, Verhaeghe S, Van Hecke A, Beeckman D. The Ghent Global IAD Monitoring Tool (GLOBIAD-M) to monitor the healing of incontinence-associated dermatitis (IAD): Design and reliability study. Int Wound J. 2018 Aug;15(4):555-564. doi: 10.1111/iwj.12898. Epub 2018 May 24.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- TYAFGH-D-112032
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Description du régime IPD
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .