Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Squat Jump Performance and Chiropractic Ankle Manipulation

14 juin 2026 mis à jour par: Jeanmarie R. Burke, PhD, Northeast College of Health Sciences

The Effects of Chiropractic Ankle Manipulation on Athletic Performance of College-Aged Recreational Athletes: Randomized Controlled Trial

The goal of this clinical trial is to learn if chiropractic ankle manipulation can improve squat jump performance. It will also learn about the relationship among chiropractic ankle manipulation, ankle range of motion, and squat jump performance. The main questions it aims to answer are:

  • Does chiropractic ankle manipulation increase squat jump height?
  • Is there a relationship among chiropractic ankle manipulation, ankle range of motion, and squat jump performance?

Researchers will compare squat jump performance between subjects who receive chiropractic ankle manipulations with control subjects to see if ankle chiropractic manipulation works to improve squat jump performance.

Participants will:

  • Visit the research laboratory for one testing session to measure ankle range of motion and squat jump performance, before and after their randomly assigned intervention arm
  • Receive either a chiropractic ankle manipulations or rest quietly as the control condition during the testing session.

Aperçu de l'étude

Type d'étude

Interventionnel

Inscription (Estimé)

60

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

Lieux d'étude

    • New York
      • Seneca Falls, New York, États-Unis, 13148
        • Recrutement
        • Biomechanics Laboratory at Northeast College of Health Sciences
        • Contact:

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte

Accepte les volontaires sains

Oui

La description

Inclusion Criteria

  • age range from 18 to 35 years old; and
  • participating in recreational exercise, three times a week for at least 30 minutes. Recreational exercise includes ball sports (e.g. soccer, basketball, volleyball, etc.), racket sports (e.g. tennis, pickle ball, racket ball, etc.), strength/combat sports (e.g. weight lifting, boxing, martial arts, kickboxing, etc.), endurance sports (running, cycling, rock climbing, etc.), snow/ice sports (downhill or cross-county skiing, snow shoeing, hockey, etc.), interval training (e.g., high-intensity interval training), sprint interval training, repeated sprint training etc.) or moderate-intensity aerobic activities (step classes, dance classes, hiking, etc.)

Exclusion Criteria

  • professional or amateur ranked athlete;
  • participation in water sports (swimming, water aerobics, kayaking, water skiing, etc.) to meet the recreational exercise inclusion criteria
  • acute or chronic musculoskeletal injury / condition of the feet, ankles, knees, and/or hips;
  • acute or chronic musculoskeletal injury / condition of the spine;
  • pregnancy or there is a possibility of pregnancy.
  • any diagnosed medical condition; and
  • any prescribed medications with the exceptions of birth control, anxiety, or attention-deficit/hyperactivity disorder (ADHD) medications.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Double

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Chiropractic Ankle Manipulation

LEM - Lower Extremity Manipulation:

Subjects assigned to the LEM Intervention Group will receive a short lever, high velocity, low-amplitude distractive (caudal) thrust directed at the talocrural joint. The treating chiropractor will deliver the LEM to the right ankle then the left ankle. LEM is an adjustment for long axis distraction of the tibiotalar joint with the goal to improve dorsiflexion of the ankle joint.

The lower extremity manipulation (LEM) procedure is a short lever, high velocity, low-amplitude distractive (caudal) thrust directed at the talocrural joint. The treating chiropractor will deliver the LEM to the right ankle then the left ankle. LEM is an adjustment for long axis distraction of the tibiotalar joint with the goal to improve dorsiflexion of the ankle joint.
Autres noms:
  • Lower Extremity Manipulation
Aucune intervention: Control
Subjects assigned to the Control Group will rest quietly, supine (face up), on the chiropractic treatment table for five (5) minutes.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Squat Jump Height
Délai: Baseline on Day 1 to Immediately after Intervention on Day 1

Subjects will be instructed to jump upwards from the starting squat position as high as possible. Subjects will perform 3 to 6 jumps with 3 consecutive jump heights being within 5% of each other to ensure maximum jump height is achieved. There will be a one-minute rest between jumps.

  • Starting position. Subjects will assume the starting squat position with their hips at 90°, knees at 120°, and ankles at 85° as positioned by the PI. An adjustable plyometric jump box will be used to standardize the starting position. Hands will be resting across their chest with the trunk and head positioned straight ahead.
  • Squat Jump: Subjects will be instructed to jump as high as possible and land in a comfortable position. Hands will remain across the chest for the duration of

The Optojump photoelectric cell system (OptoJump) will be used to record jump height. OptoJump demonstrates strong concurrent validity and excellent test-retest reliability for the estimation of vertical jump height

Baseline on Day 1 to Immediately after Intervention on Day 1
Range of Motion of Ankle Dorsiflexion
Délai: Baseline on Day 1 to Immediately after Treatment on Day 1 and at End of Test Session on Day 1

Knee-to-wall ankle dorsiflexion test:

  • Ankle dorsiflexion ROM (distance from wall - cm) is the maximum distance of the big toe from the wall while maintaining contact between the wall and the knee with the heel on the ground.
  • The subject will repeat the Knee-to-wall ankle dorsiflexion test three times at this maximum distance to allow the PI to record three goniometer measurements of ankle dorsiflexion ROM (degrees°).
Baseline on Day 1 to Immediately after Treatment on Day 1 and at End of Test Session on Day 1

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Leg Muscle Power (W/Kg)
Délai: Baseline on Day 1 to Immediately after Intervention on Day 1
Squat Jump Muscle Parameter: The Optojump will calculate an estimate of leg muscle power (W/Kg). The reliability and concurrent validity of OptoJump to measure jump height suggests that the evidence-base biomechanical formula to calculate the estimate of leg muscle power by OptoJump is reliable with face validity.
Baseline on Day 1 to Immediately after Intervention on Day 1
Contraction Velocity of Leg Muscles (mm/s), Force-Velocity Curve
Délai: Baseline on Day 1 to Immediately after Intervention on Day 1

Squat Jump Muscle Parameter: The Gyko inertial sensor system (Gyko) will measure the velocity of the jump to calculate an estimate of the contraction velocity of leg muscles, force-velocity curve.

The reliability and concurrent validity of Gyko to measure jump height and in-turn estimate muscle function parameters is limited in the literature. The control group in the current study will allow us to address concurrent validity and reliability of Gyko to measure jump height. Jump height measured by Optojump is the gold-standard field base device. Comparison of Gyko to Optojump measurements of jump heights will determine concurrent validity of Gyko to estimate jump height. The use of evidence-base biomechanical formulas to calculate an estimate of contraction velocity of leg muscles during SQJ's depends on recording reliable and valid measurements of jump heights; and in turn, establish the reliability and face validity of Gyko to estimate muscle function parameters.

Baseline on Day 1 to Immediately after Intervention on Day 1
Rate of Force Development of Leg Muscles (N/s), Slope of the Force - Velocity Curve
Délai: Baseline on Day 1 to Immediately after Intervention on Day 1
Squat Jump Muscle Parameter: The Gyko inertial sensor system (Gyko) will measure the velocity of the jump to calculate an estimate of the rate of force development of leg muscles, slope of the force - velocity curve The reliability and concurrent validity of Gyko to measure jump height and in-turn estimate muscle function parameters is limited in the literature. The control group in the current study will allow us to address concurrent validity and reliability of Gyko to measure jump height. Jump height measured by Optojump is the gold-standard field base device. Comparison of Gyko to Optojump measurements of jump heights will determine concurrent validity of Gyko to estimate jump height. The use of evidence-base biomechanical formulas to calculate an estimate of the rate of force development of leg muscles during SQJ's depends on recording reliable and valid measurements of jump heights; and in turn, establish the reliability and face validity of Gyko to estimate muscle function.
Baseline on Day 1 to Immediately after Intervention on Day 1

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Estimé)

1 juin 2026

Achèvement primaire (Estimé)

1 mai 2027

Achèvement de l'étude (Estimé)

1 mai 2027

Dates d'inscription aux études

Première soumission

31 mai 2026

Première soumission répondant aux critères de contrôle qualité

7 juin 2026

Première publication (Réel)

11 juin 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

16 juin 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

14 juin 2026

Dernière vérification

1 mai 2026

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • 26-02

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner