Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Validity and Reliability of Mixed Reality-Based Functional Mobility Tests in Type 2 Diabetes

11 juin 2026 mis à jour par: Mehmet Kaan ALTUNOK, Selcuk University

Validity and Reliability of the Mixed Reality Adaptation of the 6-Minute Walk, Timed Up and Go, and Five-Repetition Sit-to-Stand Tests in Individuals With Type 2 Diabetes Mellitus

Type 2 Diabetes Mellitus (T2DM) is a multifaceted metabolic disease associated not only with impaired glycemic control but also with reductions in muscle strength, balance, functional mobility, and walking performance. Individuals with T2DM may experience impairments in lower extremity function, postural control, and overall functional performance, which can negatively affect activities of daily living and quality of life. Therefore, the assessment of functional performance using reliable and valid methods is important for clinical monitoring and rehabilitation planning.

The 6-Minute Walk Test (6MWT), Timed Up and Go Test (TUG), and Five-Repetition Sit-to-Stand Test (5xSTS) are widely used clinical assessments for evaluating walking capacity, functional mobility, lower extremity function, and physical performance in individuals with T2DM. Previous studies have demonstrated that these tests provide reliable and clinically meaningful measurements in this population.

In recent years, virtual and mixed reality technologies have provided opportunities to conduct assessments in a more objective, standardized, and user-friendly manner. These technologies also offer important advantages, including real-time data collection, enhanced user interaction, and potential integration into future remote assessment applications. However, evidence regarding the measurement properties of mixed reality-based adaptations of commonly used functional performance tests in individuals with T2DM remains limited.

The aim of this study is to evaluate the validity and reliability of mixed reality-based adaptations of the 6-Minute Walk Test, Timed Up and Go Test, and Five-Repetition Sit-to-Stand Test developed using the Meta Quest 3 platform. In addition, convergent validity will be examined by investigating the relationships between outcomes obtained from the mixed reality-based assessments and measures of knee extensor muscle strength and handgrip strength.

The findings of this study are expected to contribute to the development of innovative, safe, standardized, and digital approaches for assessing functional performance in individuals with Type 2 Diabetes Mellitus. Furthermore, the results may provide a scientific foundation for future digital health applications and remote assessment strategies.

Aperçu de l'étude

Type d'étude

Observationnel

Inscription (Estimé)

75

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

Lieux d'étude

    • Selcuklu
      • Konya, Selcuklu, Turquie (Türkiye), 42130
        • Recrutement
        • Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation
        • Contact:

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Non

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Adults aged 18-65 years diagnosed with Type 2 Diabetes Mellitus who are able to ambulate independently, are clinically stable, and are eligible to participate in conventional and mixed reality-based functional performance assessments.

La description

Inclusion Criteria:

  • Diagnosed with Type 2 Diabetes Mellitus by a physician,
  • Aged between 18 and 65 years,
  • Ability to ambulate independently without the use of an assistive device,
  • No participation in a structured exercise program within the previous 6 months,
  • Cognitive ability sufficient to understand and follow test instructions,
  • Visual, auditory, and vestibular functions sufficient to tolerate mixed reality applications,
  • Ability to read, understand, and follow instructions in Turkish,
  • Willingness to participate voluntarily in the study and provision of written informed consent.

Exclusion Criteria:

  • Presence of proliferative diabetic retinopathy or severe non-proliferative diabetic retinopathy,
  • Advanced peripheral neuropathy, active foot ulcer, Charcot foot, or significant sensory loss that may compromise safe test performance,
  • Presence of peripheral arterial disease,
  • Advanced renal failure, requirement for dialysis, or nephropathy that may compromise exercise safety,
  • Myocardial infarction within the previous 6 months,
  • Unstable ischemic heart disease or uncontrolled angina,
  • Resting blood pressure greater than 160/100 mmHg,
  • Presence of severe musculoskeletal, neurological, or vestibular disorders that may interfere with safe test performance,
  • High risk of balance loss or spatial disorientation in the mixed reality environment due to visual, auditory, or balance impairments,
  • Cognitive, behavioral, or compliance-related problems that may prevent completion of the study procedures.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Cohortes et interventions

Groupe / Cohorte
Intervention / Traitement
Individuals with Type 2 Diabetes Mellitus
Adults aged 18-65 years diagnosed with Type 2 Diabetes Mellitus who will undergo conventional and mixed reality-based assessments of functional performance, including the 6-Minute Walk Test, Timed Up and Go Test, and Five-Repetition Sit-to-Stand Test. Additional assessments of knee extensor muscle strength and handgrip strength will be performed to evaluate convergent validity.
Participants will perform mixed reality-based adaptations of the 6-Minute Walk Test (6MW-MR), Timed Up and Go Test (TUG-MR), and Five-Repetition Sit-to-Stand Test (5xSTS-MR) developed for the Meta Quest 3 platform. The mixed reality environment digitally replicates the conventional test setups and provides standardized visual guidance while allowing participants to interact safely with the real environment. Test outcomes will be automatically recorded by the system and compared with conventional clinical assessments to evaluate validity. The mixed reality-based tests will be repeated one week later to assess test-retest reliability.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
6-Minute Walk Test - Mixed Reality (6MW-MR)
Délai: Baseline and 1-week follow-up
Functional exercise capacity and walking endurance will be assessed using a mixed reality-based adaptation of the 6-Minute Walk Test. Walking distance will be recorded in meters, with greater distances indicating better performance. Validity will be evaluated by comparison with the conventional 6-Minute Walk Test, and reliability will be assessed using repeated measurements performed one week apart.
Baseline and 1-week follow-up
Timed Up and Go Test - Mixed Reality (TUG-MR)
Délai: Baseline and 1-week follow-up
Functional mobility will be assessed using a mixed reality-based adaptation of the Timed Up and Go Test. Test completion time will be recorded in seconds, with shorter times indicating better functional mobility. Validity and reliability will be evaluated through comparison with the conventional Timed Up and Go Test and repeated measurements.
Baseline and 1-week follow-up
Five-Repetition Sit-to-Stand Test - Mixed Reality (5xSTS-MR)
Délai: Baseline and 1-week follow-up
Lower extremity functional performance will be assessed using a mixed reality-based adaptation of the Five-Repetition Sit-to-Stand Test. Test duration will be recorded in seconds, with shorter times indicating better performance. Validity and reliability will be evaluated through comparison with the conventional Five-Repetition Sit-to-Stand Test and repeated measurements.
Baseline and 1-week follow-up

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Participant Satisfaction
Délai: Baseline
Participant satisfaction with conventional and mixed reality-based assessments will be evaluated using a 10-point visual analog scale ranging from 1 to 10, with higher scores indicating greater satisfaction.
Baseline
6-Minute Walk Test - Conventional
Délai: Baseline
Walking distance measured during the conventional 6-Minute Walk Test will be used as a reference measure for concurrent validity analyses. Greater distances indicate better functional exercise capacity.
Baseline
Timed Up and Go Test - Conventional
Délai: Baseline
The conventional Timed Up and Go Test will be administered to assess functional mobility and will serve as a reference measure for validity analyses. Test completion time will be recorded in seconds, with shorter times indicating better functional mobility.
Baseline
Five-Repetition Sit-to-Stand Test - Conventional
Délai: Baseline
The conventional Five-Repetition Sit-to-Stand Test will be used as a reference measure for validity analyses. Test completion time will be recorded in seconds, with shorter times indicating better lower extremity functional performance.
Baseline
Knee Extensor Muscle Strength
Délai: Baseline
Knee extensor muscle strength will be measured using a handheld digital dynamometer. Maximum voluntary contraction values will be recorded, with higher values indicating greater muscle strength. Outcomes will be analyzed for convergent validity with mixed reality-based test results.
Baseline
Handgrip Strength
Délai: Baseline
Handgrip strength will be assessed using a hand dynamometer. The highest value obtained from repeated trials will be recorded, with higher values indicating greater muscle strength. Outcomes will be analyzed for convergent validity with mixed reality-based test results.
Baseline

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Les enquêteurs

  • Chaise d'étude: Gülşah ÖZSOY, Assist. Prof. Dr., Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Konya, Türkiye
  • Chaise d'étude: Zehra KORKUT, Assist. Prof. Dr., Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Konya, Türkiye
  • Chaise d'étude: İsmail ÖZSOY, Assoc. Prof. Dr., Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Konya, Türkiye
  • Chaise d'étude: Mehmet A GÜLER, PhD, Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Konya, Türkiye
  • Chaise d'étude: İhsan KODAK, Assist. Prof. Dr., Kırşehir Ahi Evran University, School of Physical Therapy and Rehabilitation, Kırşehir, Türkiye
  • Chaise d'étude: Yasemin GEDİKLİ ERTÜRK, PhD (c) in PT, Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Konya, Türkiye
  • Chaise d'étude: Selma Ö ÇELİKDELEN, Assist. Prof. Dr., Konya City Hospital

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Publications générales

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

10 juin 2026

Achèvement primaire (Estimé)

30 décembre 2026

Achèvement de l'étude (Estimé)

10 mai 2027

Dates d'inscription aux études

Première soumission

11 juin 2026

Première soumission répondant aux critères de contrôle qualité

11 juin 2026

Première publication (Réel)

16 juin 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

16 juin 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

11 juin 2026

Dernière vérification

1 juin 2026

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner