Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Validity and Reliability of Mixed Reality-Based Functional Mobility Tests in Type 2 Diabetes

11 juni 2026 bijgewerkt door: Mehmet Kaan ALTUNOK, Selcuk University

Validity and Reliability of the Mixed Reality Adaptation of the 6-Minute Walk, Timed Up and Go, and Five-Repetition Sit-to-Stand Tests in Individuals With Type 2 Diabetes Mellitus

Type 2 Diabetes Mellitus (T2DM) is a multifaceted metabolic disease associated not only with impaired glycemic control but also with reductions in muscle strength, balance, functional mobility, and walking performance. Individuals with T2DM may experience impairments in lower extremity function, postural control, and overall functional performance, which can negatively affect activities of daily living and quality of life. Therefore, the assessment of functional performance using reliable and valid methods is important for clinical monitoring and rehabilitation planning.

The 6-Minute Walk Test (6MWT), Timed Up and Go Test (TUG), and Five-Repetition Sit-to-Stand Test (5xSTS) are widely used clinical assessments for evaluating walking capacity, functional mobility, lower extremity function, and physical performance in individuals with T2DM. Previous studies have demonstrated that these tests provide reliable and clinically meaningful measurements in this population.

In recent years, virtual and mixed reality technologies have provided opportunities to conduct assessments in a more objective, standardized, and user-friendly manner. These technologies also offer important advantages, including real-time data collection, enhanced user interaction, and potential integration into future remote assessment applications. However, evidence regarding the measurement properties of mixed reality-based adaptations of commonly used functional performance tests in individuals with T2DM remains limited.

The aim of this study is to evaluate the validity and reliability of mixed reality-based adaptations of the 6-Minute Walk Test, Timed Up and Go Test, and Five-Repetition Sit-to-Stand Test developed using the Meta Quest 3 platform. In addition, convergent validity will be examined by investigating the relationships between outcomes obtained from the mixed reality-based assessments and measures of knee extensor muscle strength and handgrip strength.

The findings of this study are expected to contribute to the development of innovative, safe, standardized, and digital approaches for assessing functional performance in individuals with Type 2 Diabetes Mellitus. Furthermore, the results may provide a scientific foundation for future digital health applications and remote assessment strategies.

Studie Overzicht

Studietype

Observationeel

Inschrijving (Geschat)

75

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studiecontact

Studie Locaties

    • Selcuklu
      • Konya, Selcuklu, Turkije (Türkiye), 42130
        • Werving
        • Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation
        • Contact:

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

Nee

Bemonsteringsmethode

Niet-waarschijnlijkheidssteekproef

Studie Bevolking

Adults aged 18-65 years diagnosed with Type 2 Diabetes Mellitus who are able to ambulate independently, are clinically stable, and are eligible to participate in conventional and mixed reality-based functional performance assessments.

Beschrijving

Inclusion Criteria:

  • Diagnosed with Type 2 Diabetes Mellitus by a physician,
  • Aged between 18 and 65 years,
  • Ability to ambulate independently without the use of an assistive device,
  • No participation in a structured exercise program within the previous 6 months,
  • Cognitive ability sufficient to understand and follow test instructions,
  • Visual, auditory, and vestibular functions sufficient to tolerate mixed reality applications,
  • Ability to read, understand, and follow instructions in Turkish,
  • Willingness to participate voluntarily in the study and provision of written informed consent.

Exclusion Criteria:

  • Presence of proliferative diabetic retinopathy or severe non-proliferative diabetic retinopathy,
  • Advanced peripheral neuropathy, active foot ulcer, Charcot foot, or significant sensory loss that may compromise safe test performance,
  • Presence of peripheral arterial disease,
  • Advanced renal failure, requirement for dialysis, or nephropathy that may compromise exercise safety,
  • Myocardial infarction within the previous 6 months,
  • Unstable ischemic heart disease or uncontrolled angina,
  • Resting blood pressure greater than 160/100 mmHg,
  • Presence of severe musculoskeletal, neurological, or vestibular disorders that may interfere with safe test performance,
  • High risk of balance loss or spatial disorientation in the mixed reality environment due to visual, auditory, or balance impairments,
  • Cognitive, behavioral, or compliance-related problems that may prevent completion of the study procedures.

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

Cohorten en interventies

Groep / Cohort
Interventie / Behandeling
Individuals with Type 2 Diabetes Mellitus
Adults aged 18-65 years diagnosed with Type 2 Diabetes Mellitus who will undergo conventional and mixed reality-based assessments of functional performance, including the 6-Minute Walk Test, Timed Up and Go Test, and Five-Repetition Sit-to-Stand Test. Additional assessments of knee extensor muscle strength and handgrip strength will be performed to evaluate convergent validity.
Participants will perform mixed reality-based adaptations of the 6-Minute Walk Test (6MW-MR), Timed Up and Go Test (TUG-MR), and Five-Repetition Sit-to-Stand Test (5xSTS-MR) developed for the Meta Quest 3 platform. The mixed reality environment digitally replicates the conventional test setups and provides standardized visual guidance while allowing participants to interact safely with the real environment. Test outcomes will be automatically recorded by the system and compared with conventional clinical assessments to evaluate validity. The mixed reality-based tests will be repeated one week later to assess test-retest reliability.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
6-Minute Walk Test - Mixed Reality (6MW-MR)
Tijdsspanne: Baseline and 1-week follow-up
Functional exercise capacity and walking endurance will be assessed using a mixed reality-based adaptation of the 6-Minute Walk Test. Walking distance will be recorded in meters, with greater distances indicating better performance. Validity will be evaluated by comparison with the conventional 6-Minute Walk Test, and reliability will be assessed using repeated measurements performed one week apart.
Baseline and 1-week follow-up
Timed Up and Go Test - Mixed Reality (TUG-MR)
Tijdsspanne: Baseline and 1-week follow-up
Functional mobility will be assessed using a mixed reality-based adaptation of the Timed Up and Go Test. Test completion time will be recorded in seconds, with shorter times indicating better functional mobility. Validity and reliability will be evaluated through comparison with the conventional Timed Up and Go Test and repeated measurements.
Baseline and 1-week follow-up
Five-Repetition Sit-to-Stand Test - Mixed Reality (5xSTS-MR)
Tijdsspanne: Baseline and 1-week follow-up
Lower extremity functional performance will be assessed using a mixed reality-based adaptation of the Five-Repetition Sit-to-Stand Test. Test duration will be recorded in seconds, with shorter times indicating better performance. Validity and reliability will be evaluated through comparison with the conventional Five-Repetition Sit-to-Stand Test and repeated measurements.
Baseline and 1-week follow-up

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Participant Satisfaction
Tijdsspanne: Baseline
Participant satisfaction with conventional and mixed reality-based assessments will be evaluated using a 10-point visual analog scale ranging from 1 to 10, with higher scores indicating greater satisfaction.
Baseline
6-Minute Walk Test - Conventional
Tijdsspanne: Baseline
Walking distance measured during the conventional 6-Minute Walk Test will be used as a reference measure for concurrent validity analyses. Greater distances indicate better functional exercise capacity.
Baseline
Timed Up and Go Test - Conventional
Tijdsspanne: Baseline
The conventional Timed Up and Go Test will be administered to assess functional mobility and will serve as a reference measure for validity analyses. Test completion time will be recorded in seconds, with shorter times indicating better functional mobility.
Baseline
Five-Repetition Sit-to-Stand Test - Conventional
Tijdsspanne: Baseline
The conventional Five-Repetition Sit-to-Stand Test will be used as a reference measure for validity analyses. Test completion time will be recorded in seconds, with shorter times indicating better lower extremity functional performance.
Baseline
Knee Extensor Muscle Strength
Tijdsspanne: Baseline
Knee extensor muscle strength will be measured using a handheld digital dynamometer. Maximum voluntary contraction values will be recorded, with higher values indicating greater muscle strength. Outcomes will be analyzed for convergent validity with mixed reality-based test results.
Baseline
Handgrip Strength
Tijdsspanne: Baseline
Handgrip strength will be assessed using a hand dynamometer. The highest value obtained from repeated trials will be recorded, with higher values indicating greater muscle strength. Outcomes will be analyzed for convergent validity with mixed reality-based test results.
Baseline

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Studie stoel: Gülşah ÖZSOY, Assist. Prof. Dr., Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Konya, Türkiye
  • Studie stoel: Zehra KORKUT, Assist. Prof. Dr., Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Konya, Türkiye
  • Studie stoel: İsmail ÖZSOY, Assoc. Prof. Dr., Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Konya, Türkiye
  • Studie stoel: Mehmet A GÜLER, PhD, Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Konya, Türkiye
  • Studie stoel: İhsan KODAK, Assist. Prof. Dr., Kırşehir Ahi Evran University, School of Physical Therapy and Rehabilitation, Kırşehir, Türkiye
  • Studie stoel: Yasemin GEDİKLİ ERTÜRK, PhD (c) in PT, Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Konya, Türkiye
  • Studie stoel: Selma Ö ÇELİKDELEN, Assist. Prof. Dr., Konya City Hospital

Publicaties en nuttige links

De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.

Algemene publicaties

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

10 juni 2026

Primaire voltooiing (Geschat)

30 december 2026

Studie voltooiing (Geschat)

10 mei 2027

Studieregistratiedata

Eerst ingediend

11 juni 2026

Eerst ingediend dat voldeed aan de QC-criteria

11 juni 2026

Eerst geplaatst (Werkelijk)

16 juni 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

16 juni 2026

Laatste update ingediend die voldeed aan QC-criteria

11 juni 2026

Laatst geverifieerd

1 juni 2026

Meer informatie

Termen gerelateerd aan deze studie

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren