Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

USAGE OF ARITIFICIAL INTELLIGENCE IN AIDING WITH COLONIC SESSILE SERRATED LESIONS DETECTION AND DIAGNOSIS (AI-SSL) (AI-SSLD)

10 juin 2026 mis à jour par: Chew Wei Da, National Healthcare Group, Singapore

USAGE OF ARITIFICIAL INTELLIGENCE IN AIDING WITH COLONIC SESSILE SERRATED LESIONS DETECTION AND DIAGNOSIS (AI-SSLD)

The aim of this study is to is to evaluate if a real-time Computer Aided Detection (CADe) system can help improve the detection of SSL(sessile serrated lesions) versus a conventional colonoscopy (CC) using white light examination(WLE).

Aperçu de l'étude

Statut

Recrutement

Intervention / Traitement

Description détaillée

The serrated pathway is believed to account for 30% of all colorectal cancers (CRC). However, as detection rates vary widely among endoscopists and pathologists, there is uncertainty about the prevalence of these lesions [1]. Prevalence varies with study location, diagnostic criteria and examination quality. Relatively little is known about the epidemiology of these lesions (prevalence, location, family history) and risk of malignant transformation (timing, associated factors). A systematic review reported prevalence of sessile serrated lesions (SSL) was 3.9% in Europe and 5.1% in the US.

In Asia, only few reports on Sessile Serrated lesion (SSL) have been published. In a CRC screening study from Hong Kong recruiting 6,011 subjects, 486 (8.1%) subjects were reported to have HPs and only 85 (1.4%) SSL [2]. A study from Japan recruiting 5,218 asymptomatic subjects for CRC screening reported detection rates of serrated lesions of 23.3% and of right-sided serrated lesions of 7.6% respectively [3]. In this study, high-quality video endoscopes with narrow-band imaging (NBI) and magnification were used with 0.4% indigo carmine dye to enhance the detection of flat lesions. On the other hand, In Australia, the prevalence of SSL in Chinese (2%) was lower when compared with Caucasian (7%) subjects [4]. Studies have shown that SSLs are associated with CRC, especially those on the right colon and in the elderly age group, and hence should be detected and remove.[5] In addition to the potential for malignant transformation of SSL, individuals with these lesions are reportedly at higher risk of development of synchronous and metachronous CRC and advanced colorectal neoplasia (ACN) at other sites. [6-8]

Training for endoscopists and pathologists to identify SSL will likely increase detection rates, improve the prevalence of estimates of these lesions and hence reduce the incidence of interval post-colonoscopy colorectal cancer [9] The high variability between studies on the SSL prevalence, is at least partly explained by varying detection rates of serrated lesions between endoscopists, as this rate appears highly operator dependent.

Currently, CADe has been shown to improve adenoma detection rate by around 30%.[10] With the existing algorithm, SSL detection has not been improved irrespective of endoscopist experience, system type or healthcare setting. [11] This is because focus has always been put on adenomatous polyps. SSLs are sessile or flat lesions measuring average size 5-7mm and can be easily missed during conventional colonoscopy as they are usually normal to pale in color They may exhibit distinct endoscopic features such as overlying mucus cap, cloud-like surface, ring of debris or stool around the lesion and obscured mucosal vasculature During narrow-band imaging endoscopy, they have a cloud-like appearance, irregular shape, and dark spots inside the crypts. Better bowel preparation, longer withdrawal time, and careful examination of the right colon (with repeated anterograde examination or retroflexion in the caecum) improved detection of SSL [12]. Electronic chromoendoscopy such as NBI may marginally improve the detection of SSL but is currently not recommended as mandatory practice, because clear scientific evidence is lacking.

Usage of CADe system has been shown in several studies to improve polyp detection rate even amongst junior endoscopists but however most of the CADE system is trained to focus on adenomatous polyp. This AI algorithm has been trained to detect SSL. If proven to be effective in a real-world setting, this will improve outcomes of patients undergoing colonoscopies and reduce the risk of interval colon cancers post colonoscopies.

We hypothesise that usage of CADe system can improve SSL detection significantly from 2% with conventional White Light endoscopy to 6.5%.

Type d'étude

Interventionnel

Inscription (Estimé)

628

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

Sauvegarde des contacts de l'étude

Lieux d'étude

      • Singapore, Singapour, 308433
      • Singapore, Singapour
      • Singapore, Singapour
        • Pas encore de recrutement
        • Changi General Hospital
        • Contact:
          • Clinical Research Coordinator
          • Numéro de téléphone: 6569365716
          • E-mail: ctru@cgh.com.sg
        • Contact:
        • Chercheur principal:
          • Tiing Leong Ang, Phd

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Oui

La description

Inclusion Criteria:

Adult (40 - 80 years) Undergoing colonoscopy for screening, surveillance, or diagnostic indications. Complete colonoscopy with satisfactory Boston Bowel Prep Scale of 6 or higher. Provide informed consent to participate in the study

Exclusion Criteria:

Personal or family history of colorectal cancer Personal or family history of colonic polyposis syndromes Personal or family history of inflammatory bowel disease Prior colorectal surgery Contraindications to colonoscopy (intestinal obstruction, medical conditions that will make the risk of colonoscopy too high) Contraindications to polypectomy (ongoing anticoagulation / double antiplatelet therapy that cannot be stopped for the colonoscopy) Inability to give consent Incomplete colonoscopy/ Unable to retrieve specimen for pathology Poor bowel preparation (Boston Bowel Prep Scale <6) Pregnant Women

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Dépistage
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Seul

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Comparateur actif: AI-assisted colonoscopy
A real-time Computer Aided Detection (CADe) system can help improve the detection of SSL versus a conventional colonoscopy (CC) using white light examination(WLE).
Aucune intervention: Conventional Colonoscopy
Conventional Colonoscopy using white light

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Délai
SSL per colonoscopy (SPC) using White Light Endoscopy alone vs enhancement by CADe system.
Délai: up to a year
up to a year

Mesures de résultats secondaires

Mesure des résultats
Délai
1) Adenoma per colonoscopy (APC) using White Light Endoscopy alone vs enhancement by CADe system. 2) Polyp per colonoscopy (PPC) using White Light Endoscopy alone vs enhancement by CADe system. 3) Difference in the SPC, APC, PPC for each proceduralist
Délai: up to a year
up to a year

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Les enquêteurs

  • Chaise d'étude: Joseph JY Sung, PHD, Nanyang Technological University

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Publications générales

  • 1.Meester RGS, van Herk M, Lansdorp-Vogelaar I, et al. Prevalence and clinical features of sessile serrated polyps: a systematic review. Gastroenterology 2020;159:105-118.e25 2.Lui, R. N. et al. Prevalence and risk factors for sessile serrated lesions in an average risk colorectal cancer screening population. J. Gastroenterol. Hepatol. 36, 1656-1662 (2021) 3.Sekiguchi M, Matsuda T Prevalence of serrated lesions, risk factors, and their association with synchronous advanced colorectal neoplasia in asymptomatic screened individuals. J Gastroenterol Hepatol. 2020 Nov;35(11):1938-1944 doi: 10.1111/jgh.15116. Epub 2020 Jun 10 4.Sung JJY, Chiu HM Third Asia-Pacific consensus recommendations on colorectal cancer screening and postpolypectomy surveillance. Gut. 2022 Nov;71(11):2152-2166. doi: 10.1136/gutjnl-2022-327377. Epub 2022 Aug 24 5.Song M, Emilsson L, Bozorg SR, et al. Risk of colorectal cancer incidence and mortality after polypectomy: a Swedish recordlinkage study. Lancet Gastroenterol Hepatol 2020;5:537-547. 6.Gao Q, Tsoi KK, Hirai HW, et al. Serrated polyps and the risk of synchronous colorectal advanced neoplasia: a systematic review and meta-analysis. Am J Gastroenterol. 2015; 110: 501-9. 7.He X, Hang D, Wu K, et al. Long-term Risk of Colorectal Cancer After Removal of Conventional Adenomas and Serrated Polyps. Gastroenterology. 2020; 158: 852-61. 8.Ng SC, Sung JJ. Association between serrated polyps and the risk of synchronous advanced colorectal neoplasia in average-risk individuals. Aliment Pharmacol Ther. 2015 Jan;41(1):108-15. doi: 10.1111/apt.13003. Epub 2014 Oct 22. PMID: 25339583. 9.David E F W M van Toledo et al, Serrated polyp detection and risk of interval post-colonoscopy colorectal cancer: a population-based study, The Lancet Gastroenterology & Hepatology, Volume 7, Issue 8, 2022, Pages 747-754 10.Repici A, Hassan C. Efficacy of Real-Time Computer-Aided Detection of Colorectal Neoplasia in a Randomized Trial. Gastroenterology. 2020 Aug;159(2)

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

21 mai 2026

Achèvement primaire (Estimé)

1 mai 2027

Achèvement de l'étude (Estimé)

3 mai 2027

Dates d'inscription aux études

Première soumission

10 juin 2026

Première soumission répondant aux critères de contrôle qualité

10 juin 2026

Première publication (Réel)

16 juin 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

16 juin 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

10 juin 2026

Dernière vérification

1 juin 2026

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • 2025-1940

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

INDÉCIS

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner