Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Measuring Knee Laxity and Pivot Shift in ACL-Deficient Patients

30 juin 2026 mis à jour par: Arthroresearch LLC

Objective Quantification of Knee Laxity Using a Robotic Knee Testing System and Correlation With Clinical Pivot Shift Grade in ACL-Deficient Patients

The goal of this observational study is to learn whether the Robotic Knee Testing system can measure knee looseness in adults with an anterior cruciate ligament, or ACL, tear.

The main question it aims to answer is whether measurements from the Robotic Knee Testing system are related to the doctor's pivot shift exam grade.

Participants will complete one study visit before ACL reconstruction. During the visit, both knees will be tested in the Robotic Knee Testing system. Researchers may also review existing medical information and imaging.

Aperçu de l'étude

Statut

Pas encore de recrutement

Description détaillée

This study includes two parts. In Phase 1, researchers will adjust the Robotic Knee Testing system settings to identify testing conditions that are safe, tolerable, and able to reproduce knee motion similar to the pivot shift exam.

During Phase 1, the device will test how knee motion changes when the leg is placed in different positions. Researchers will evaluate whether tibial internal rotation and knee flexion angle change varus-valgus knee motion. They will also evaluate whether varus-valgus knee position and knee flexion angle change internal-external tibial rotation. These tests are intended to help identify device settings that may reproduce the coupled motion seen during a clinical pivot shift exam.

The robotic torque-motion curves will also be reviewed for abrupt changes, discontinuities, or "jumps." These findings may represent the knee moving from a stable position into an unstable position.

In Phase 2, participants will be tested using the finalized device settings from Phase 1. The device will apply controlled anterior-posterior, internal-external rotation, and varus-valgus movements while measuring knee motion in six degrees of freedom. Researchers will compare the robotic measurements with the pivot shift grade documented by the treating orthopedic surgeon.

When available, existing MRI or X-ray images may also be reviewed to evaluate whether knee bone structure is related to robotic laxity measurements or pivot shift severity. No additional imaging will be performed for this study.

Type d'étude

Observationnel

Inscription (Estimé)

25

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

Sauvegarde des contacts de l'étude

Lieux d'étude

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Non

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Study participants will be selected from patients being treated for ACL injury by orthopedic providers in the Atlanta metropolitan area. Participants will generally be identified through orthopedic clinic schedules, clinical referrals, or patients scheduled for ACL reconstruction.

La description

Inclusion Criteria:

  • Adults aged 18-65 years
  • Confirmed ACL tear by MRI or arthroscopic diagnosis
  • Able to provide informed consent

Exclusion Criteria:

  • Prior major surgery on the affected knee
  • Multi-ligament knee injury
  • Active infection or inflammatory arthropathy
  • Inability to tolerate passive motion testing
  • Pregnant or planning to become pregnant during the study period
  • Unable to provide informed consent

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Clinician-graded pivot shift
Délai: Before ACL reconstruction, during the preoperative clinical exam and/or examination under anesthesia.
Clinician-graded pivot shift from 0 to 3, obtained from the treating orthopedic surgeon's preoperative clinical exam and/or examination under anesthesia before ACL reconstruction.
Before ACL reconstruction, during the preoperative clinical exam and/or examination under anesthesia.
Association Between RKT Knee Motion Measurements and Clinician-Graded Pivot Shift Grade
Délai: RKT testing at the preoperative study visit and pivot shift grading before ACL reconstruction
Relationship between Robotic Knee Testing measurements of tibiofemoral motion and clinician-graded pivot shift grade from 0 to 3. RKT measurements may include tibial translation and rotation during robotic testing.
RKT testing at the preoperative study visit and pivot shift grading before ACL reconstruction

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
RKT Torque-Motion Hysteresis Curve Features
Délai: During RKT testing at the preoperative study visit before ACL reconstruction
Torque-displacement and torque-rotation curves from robotic testing will be evaluated for features such as slope changes, curve area, discontinuities, or "jumps" that may reflect knee instability.
During RKT testing at the preoperative study visit before ACL reconstruction
Effect of Knee Position on RKT Motion Measurements
Délai: During RKT testing at the preoperative study visit before ACL reconstruction
RKT measurements will be compared across different testing conditions, including tibial internal rotation angle, varus-valgus knee position, knee flexion angle, and preset torque thresholds, to identify settings associated with pivot-shift-like motion.
During RKT testing at the preoperative study visit before ACL reconstruction
Association Between Bone Morphology and Knee Instability Measurements
Délai: Existing imaging reviewed after enrollment and before data analysis
Existing MRI or X-ray images may be reviewed to assess bone morphology, including posterior tibial slope and femoral-tibial plateau geometry, and compare these measures with RKT measurements and pivot shift grade.
Existing imaging reviewed after enrollment and before data analysis

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Les enquêteurs

  • Chercheur principal: Shaun K Stinton, PhD, Arthroresearch LLC

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Estimé)

7 juillet 2026

Achèvement primaire (Estimé)

1 juillet 2027

Achèvement de l'étude (Estimé)

1 juillet 2027

Dates d'inscription aux études

Première soumission

30 juin 2026

Première soumission répondant aux critères de contrôle qualité

30 juin 2026

Première publication (Réel)

7 juillet 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

7 juillet 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

30 juin 2026

Dernière vérification

1 juin 2026

Plus d'information

Termes liés à cette étude

Termes MeSH pertinents supplémentaires

Autres numéros d'identification d'étude

  • 15940

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner