Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Relationship Between Metrnl Expression, IL-1β, and TNF-α in Patients With Peri-Implantitis

7 novembre 2026 mis à jour par: Pinar Eser Tuna, Ataturk University

Association of Metrnl Expression With IL-1β and TNF-α in Patients With Peri-Implantitis: Potential as a Novel Biomarker

Peri-implantitis is an inflammatory disease affecting the tissues around dental implants and may lead to progressive bone loss and implant failure. Current diagnosis is mainly based on clinical and radiographic findings, which may not fully reflect the underlying inflammatory activity. Therefore, there is a need for biological markers that may provide additional information about disease-related changes.

This observational study aims to compare the levels of Meteorin-like protein (Metrnl) and selected inflammatory cytokines in peri-implant crevicular fluid obtained from individuals with peri-implantitis and individuals with healthy implants. The study will evaluate Metrnl, interleukin-1 beta (IL-1β), tumor necrosis factor-alpha (TNF-α), and interleukin-10 (IL-10). It will also examine the relationships between Metrnl and these inflammatory markers.

The study hypothesis is that Metrnl levels differ between healthy peri-implant tissues and peri-implantitis and are associated with pro-inflammatory and anti-inflammatory cytokine levels. The findings may help clarify the possible role of Metrnl in peri-implant inflammation and its potential as a biomarker for distinguishing peri-implant health from peri-implantitis.

Aperçu de l'étude

Statut

Complété

Les conditions

Description détaillée

Peri-implantitis is a biofilm-associated inflammatory disease characterized by inflammation of the peri-implant mucosa and progressive loss of supporting bone. Although clinical and radiographic parameters, including probing depth, bleeding on probing, suppuration, and radiographic bone loss, are central to diagnosis, these measures primarily reflect established tissue changes and may not fully characterize the underlying local immune-inflammatory response. Analysis of biomarkers in peri-implant crevicular fluid may therefore provide complementary information about the biological processes associated with peri-implant health and disease.

Meteorin-like protein (Metrnl) is an immunoregulatory protein involved in inflammatory regulation, macrophage polarization, and tissue repair. Experimental and clinical evidence suggests that Metrnl may interact with both pro-inflammatory and anti-inflammatory pathways. However, its possible role in peri-implantitis has not been sufficiently investigated.

This observational study will include individuals with peri-implantitis and individuals with healthy peri-implant tissues. Participants will be classified according to clinical and radiographic findings. Clinical periodontal and peri-implant parameters will be recorded to characterize the study groups. Peri-implant crevicular fluid samples will be collected from selected implant sites, and the concentrations of Metrnl, interleukin-1 beta (IL-1β), tumor necrosis factor-alpha (TNF-α), and interleukin-10 (IL-10) will be analyzed.

The primary objective is to compare Metrnl levels between the peri-implantitis and peri-implant health groups. Secondary objectives are to compare IL-1β, TNF-α, and IL-10 levels between the groups and to evaluate the relationships between Metrnl and these pro-inflammatory and anti-inflammatory cytokines. The study will also explore the ability of Metrnl and the evaluated cytokines to distinguish peri-implant health from peri-implantitis.

The study hypothesis is that Metrnl levels differ between peri-implant health and peri-implantitis and are associated with the local inflammatory cytokine profile. Evaluation of these relationships may provide new information about the role of Metrnl in the immunoinflammatory mechanisms of peri-implantitis and its potential value as a biomarker.

Type d'étude

Observationnel

Inscription (Réel)

68

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Erzurum
      • Erzurum, Erzurum, Turquie (Türkiye), 25080
        • Atatürk University

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Oui

Sexes éligibles pour l'étude

Tout

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

The study population will consist of adults with at least one functioning dental implant who are evaluated at the Department of Periodontology, Faculty of Dentistry, Atatürk University. Participants will be classified into two groups according to clinical and radiographic findings: individuals with peri-implantitis and individuals with peri-implant health. Peri-implant clinical parameters and peri-implant crevicular fluid biomarker levels will be evaluated and compared between the groups.

La description

Inclusion Criteria:

  • Individuals aged 18 years or older
  • Individuals without systemic disease
  • Individuals with at least one healthy implant or one implant affected by peri-implantitis
  • At least 1 year having elapsed since placement of the prosthetic restoration on the relevant implant

Exclusion Criteria:

  • Pregnant or lactating individuals.
  • Current smokers.
  • Use of antibiotics or corticosteroids within the previous 6 months.
  • Presence of an implant-supported removable prosthesis.
  • Periodontal or peri-implant treatment within the previous 6 months.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Modèles d'observation: CASE_CONTROL
  • Perspectives temporelles: CROSS_SECTIONAL

Cohortes et interventions

Groupe / Cohorte
Peri-Implantitis Group

Individuals diagnosed with peri-implantitis based on clinical and radiographic criteria. Peri-implant crevicular fluid samples will be collected, and Metrnl, IL-1β, TNF-α, and IL-10 levels will be evaluated.

Peri-Implant Health Group

Individuals with clinically and radiographically healthy peri-implant tissues. Peri-implant crevicular fluid samples will be collected, and Metrnl, IL-1β, TNF-α, and IL-10 levels will be evaluated.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Metrnl Concentration in Peri-Implant Crevicular Fluid
Délai: At enrollment

Meteorin-like protein (Metrnl) concentration in peri-implant crevicular fluid will be quantified using a commercially available enzyme-linked immunosorbent assay (ELISA) kit (Shanghai Sunred Biological Technology Co., Ltd., Shanghai, China), according to the manufacturer's instructions, and expressed in ng/mL. Metrnl concentrations will be compared between the peri-implantitis and peri-implant health groups using an independent-samples t test for normally distributed data or a Mann-Whitney U test for non-normally distributed data.

At enrollment

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
IL-1β Concentration in Peri-Implant Crevicular Fluid
Délai: At enrollment

Interleukin-1 beta (IL-1β) concentration in peri-implant crevicular fluid will be quantified using a commercially available enzyme-linked immunosorbent assay (ELISA) kit (Shanghai Sunred Biological Technology Co., Ltd., Shanghai, China), according to the manufacturer's instructions, and expressed in pg/mL. IL-1β concentrations will be compared between the peri-implantitis and peri-implant health groups using an independent-samples t test for normally distributed data or a Mann-Whitney U test for non-normally distributed data.

At enrollment
TNF-α Concentration in Peri-Implant Crevicular Fluid
Délai: At enrollment

Tumor necrosis factor-alpha (TNF-α) concentration in peri-implant crevicular fluid will be quantified using a commercially available enzyme-linked immunosorbent assay (ELISA) kit (Shanghai Sunred Biological Technology Co., Ltd., Shanghai, China), according to the manufacturer's instructions, and expressed in pg/mL. TNF-α concentrations will be compared between the peri-implantitis and peri-implant health groups using an independent-samples t test for normally distributed data or a Mann-Whitney U test for non-normally distributed data.

At enrollment
IL-10 Concentration in Peri-Implant Crevicular Fluid
Délai: At enrollment

Interleukin-10 (IL-10) concentration in peri-implant crevicular fluid will be quantified using a commercially available enzyme-linked immunosorbent assay (ELISA) kit (Shanghai Sunred Biological Technology Co., Ltd., Shanghai, China), according to the manufacturer's instructions, and expressed in pg/mL. IL-10 concentrations will be compared between the peri-implantitis and peri-implant health groups using an independent-samples t test for normally distributed data or a Mann-Whitney U test for non-normally distributed data.

At enrollment

Autres mesures de résultats

Mesure des résultats
Description de la mesure
Délai
Correlation Between Metrnl and IL-1β Concentrations in Peri-Implant Crevicular Fluid
Délai: At enrollment

The correlation between Metrnl concentration (ng/mL) and IL-1β concentration (pg/mL) in peri-implant crevicular fluid will be evaluated. Both biomarkers will be quantified using commercially available enzyme-linked immunosorbent assay (ELISA) kits (Shanghai Sunred Biological Technology Co., Ltd., Shanghai, China) according to the manufacturer's instructions. The correlation will be quantified using a Pearson or Spearman correlation coefficient, as appropriate based on data distribution.

At enrollment
Area Under the ROC Curve for Metrnl in Distinguishing Peri-Implantitis From Peri-Implant Health
Délai: At enrollment

Metrnl concentration in peri-implant crevicular fluid will be quantified using a commercially available enzyme-linked immunosorbent assay (ELISA) kit (Shanghai Sunred Biological Technology Co., Ltd., Shanghai, China) and expressed in ng/mL. Its diagnostic ability to distinguish peri-implantitis from peri-implant health will be evaluated using receiver operating characteristic (ROC) curve analysis. Diagnostic performance will be quantified by the area under the ROC curve (AUC), a unitless measure ranging from 0 to 1.

At enrollment
Correlation Between Metrnl and TNF-α Concentrations in Peri-Implant Crevicular Fluid
Délai: At enrollment

The correlation between Metrnl concentration (ng/mL) and TNF-α concentration (pg/mL) in peri-implant crevicular fluid will be evaluated. Both biomarkers will be quantified using commercially available enzyme-linked immunosorbent assay (ELISA) kits (Shanghai Sunred Biological Technology Co., Ltd., Shanghai, China) according to the manufacturer's instructions. The correlation will be quantified using a Pearson or Spearman correlation coefficient, as appropriate based on data distribution.

At enrollment
Correlation Between Metrnl and IL-10 Concentrations in Peri-Implant Crevicular Fluid
Délai: At enrollment

The correlation between Metrnl concentration (ng/mL) and IL-10 concentration (pg/mL) in peri-implant crevicular fluid will be evaluated. Both biomarkers will be quantified using commercially available enzyme-linked immunosorbent assay (ELISA) kits (Shanghai Sunred Biological Technology Co., Ltd., Shanghai, China) according to the manufacturer's instructions. The correlation will be quantified using a Pearson or Spearman correlation coefficient, as appropriate based on data distribution.

At enrollment

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Les enquêteurs

  • Directeur d'études: Recep Orbak, DDS, PhD, Ataturk University

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

7 juillet 2026

Achèvement primaire (Réel)

1 août 2026

Achèvement de l'étude (Réel)

2 août 2026

Dates d'inscription aux études

Première soumission

6 juillet 2026

Première soumission répondant aux critères de contrôle qualité

9 juillet 2026

Première publication (Réel)

13 juillet 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

12 novembre 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

7 novembre 2026

Dernière vérification

1 novembre 2026

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • 758
  • 15367 (Autre subvention/numéro de financement: Atatürk University Scientific Research Projects Coordination Unit)

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner