- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07697729
Relationship Between Metrnl Expression, IL-1β, and TNF-α in Patients With Peri-Implantitis
Association of Metrnl Expression With IL-1β and TNF-α in Patients With Peri-Implantitis: Potential as a Novel Biomarker
Peri-implantitis is an inflammatory disease affecting the tissues around dental implants and may lead to progressive bone loss and implant failure. Current diagnosis is mainly based on clinical and radiographic findings, which may not fully reflect the underlying inflammatory activity. Therefore, there is a need for biological markers that may provide additional information about disease-related changes.
This observational study aims to compare the levels of Meteorin-like protein (Metrnl) and selected inflammatory cytokines in peri-implant crevicular fluid obtained from individuals with peri-implantitis and individuals with healthy implants. The study will evaluate Metrnl, interleukin-1 beta (IL-1β), tumor necrosis factor-alpha (TNF-α), and interleukin-10 (IL-10). It will also examine the relationships between Metrnl and these inflammatory markers.
The study hypothesis is that Metrnl levels differ between healthy peri-implant tissues and peri-implantitis and are associated with pro-inflammatory and anti-inflammatory cytokine levels. The findings may help clarify the possible role of Metrnl in peri-implant inflammation and its potential as a biomarker for distinguishing peri-implant health from peri-implantitis.
Visão geral do estudo
Status
Condições
Descrição detalhada
Peri-implantitis is a biofilm-associated inflammatory disease characterized by inflammation of the peri-implant mucosa and progressive loss of supporting bone. Although clinical and radiographic parameters, including probing depth, bleeding on probing, suppuration, and radiographic bone loss, are central to diagnosis, these measures primarily reflect established tissue changes and may not fully characterize the underlying local immune-inflammatory response. Analysis of biomarkers in peri-implant crevicular fluid may therefore provide complementary information about the biological processes associated with peri-implant health and disease.
Meteorin-like protein (Metrnl) is an immunoregulatory protein involved in inflammatory regulation, macrophage polarization, and tissue repair. Experimental and clinical evidence suggests that Metrnl may interact with both pro-inflammatory and anti-inflammatory pathways. However, its possible role in peri-implantitis has not been sufficiently investigated.
This observational study will include individuals with peri-implantitis and individuals with healthy peri-implant tissues. Participants will be classified according to clinical and radiographic findings. Clinical periodontal and peri-implant parameters will be recorded to characterize the study groups. Peri-implant crevicular fluid samples will be collected from selected implant sites, and the concentrations of Metrnl, interleukin-1 beta (IL-1β), tumor necrosis factor-alpha (TNF-α), and interleukin-10 (IL-10) will be analyzed.
The primary objective is to compare Metrnl levels between the peri-implantitis and peri-implant health groups. Secondary objectives are to compare IL-1β, TNF-α, and IL-10 levels between the groups and to evaluate the relationships between Metrnl and these pro-inflammatory and anti-inflammatory cytokines. The study will also explore the ability of Metrnl and the evaluated cytokines to distinguish peri-implant health from peri-implantitis.
The study hypothesis is that Metrnl levels differ between peri-implant health and peri-implantitis and are associated with the local inflammatory cytokine profile. Evaluation of these relationships may provide new information about the role of Metrnl in the immunoinflammatory mechanisms of peri-implantitis and its potential value as a biomarker.
Tipo de estudo
Inscrição (Real)
Contactos e Locais
Locais de estudo
-
-
Erzurum
-
Erzurum, Erzurum, Turquia (Türkiye), 25080
- Atatürk University
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
The study population will consist of adults with at least one functioning dental implant who are evaluated at the Department of Periodontology, Faculty of Dentistry, Atatürk University. Participants will be classified into two groups according to clinical and radiographic findings: individuals with peri-implantitis and individuals with peri-implant health. Peri-implant clinical parameters and peri-implant crevicular fluid biomarker levels will be evaluated and compared between the groups.
Descrição
Inclusion Criteria:
- Individuals aged 18 years or older
- Individuals without systemic disease
- Individuals with at least one healthy implant or one implant affected by peri-implantitis
- At least 1 year having elapsed since placement of the prosthetic restoration on the relevant implant
Exclusion Criteria:
- Pregnant or lactating individuals.
- Current smokers.
- Use of antibiotics or corticosteroids within the previous 6 months.
- Presence of an implant-supported removable prosthesis.
- Periodontal or peri-implant treatment within the previous 6 months.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Modelos de observação: CASE_CONTROL
- Perspectivas de Tempo: CROSS_SECTIONAL
Coortes e Intervenções
Grupo / Coorte |
|---|
|
Peri-Implantitis Group
Individuals diagnosed with peri-implantitis based on clinical and radiographic criteria. Peri-implant crevicular fluid samples will be collected, and Metrnl, IL-1β, TNF-α, and IL-10 levels will be evaluated. |
|
Peri-Implant Health Group
Individuals with clinically and radiographically healthy peri-implant tissues. Peri-implant crevicular fluid samples will be collected, and Metrnl, IL-1β, TNF-α, and IL-10 levels will be evaluated. |
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Metrnl Concentration in Peri-Implant Crevicular Fluid
Prazo: At enrollment
|
Meteorin-like protein (Metrnl) concentration in peri-implant crevicular fluid will be quantified using a commercially available enzyme-linked immunosorbent assay (ELISA) kit (Shanghai Sunred Biological Technology Co., Ltd., Shanghai, China), according to the manufacturer's instructions, and expressed in ng/mL. Metrnl concentrations will be compared between the peri-implantitis and peri-implant health groups using an independent-samples t test for normally distributed data or a Mann-Whitney U test for non-normally distributed data. |
At enrollment
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
IL-1β Concentration in Peri-Implant Crevicular Fluid
Prazo: At enrollment
|
Interleukin-1 beta (IL-1β) concentration in peri-implant crevicular fluid will be quantified using a commercially available enzyme-linked immunosorbent assay (ELISA) kit (Shanghai Sunred Biological Technology Co., Ltd., Shanghai, China), according to the manufacturer's instructions, and expressed in pg/mL. IL-1β concentrations will be compared between the peri-implantitis and peri-implant health groups using an independent-samples t test for normally distributed data or a Mann-Whitney U test for non-normally distributed data. |
At enrollment
|
|
TNF-α Concentration in Peri-Implant Crevicular Fluid
Prazo: At enrollment
|
Tumor necrosis factor-alpha (TNF-α) concentration in peri-implant crevicular fluid will be quantified using a commercially available enzyme-linked immunosorbent assay (ELISA) kit (Shanghai Sunred Biological Technology Co., Ltd., Shanghai, China), according to the manufacturer's instructions, and expressed in pg/mL. TNF-α concentrations will be compared between the peri-implantitis and peri-implant health groups using an independent-samples t test for normally distributed data or a Mann-Whitney U test for non-normally distributed data. |
At enrollment
|
|
IL-10 Concentration in Peri-Implant Crevicular Fluid
Prazo: At enrollment
|
Interleukin-10 (IL-10) concentration in peri-implant crevicular fluid will be quantified using a commercially available enzyme-linked immunosorbent assay (ELISA) kit (Shanghai Sunred Biological Technology Co., Ltd., Shanghai, China), according to the manufacturer's instructions, and expressed in pg/mL. IL-10 concentrations will be compared between the peri-implantitis and peri-implant health groups using an independent-samples t test for normally distributed data or a Mann-Whitney U test for non-normally distributed data. |
At enrollment
|
Outras medidas de resultado
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Correlation Between Metrnl and IL-1β Concentrations in Peri-Implant Crevicular Fluid
Prazo: At enrollment
|
The correlation between Metrnl concentration (ng/mL) and IL-1β concentration (pg/mL) in peri-implant crevicular fluid will be evaluated. Both biomarkers will be quantified using commercially available enzyme-linked immunosorbent assay (ELISA) kits (Shanghai Sunred Biological Technology Co., Ltd., Shanghai, China) according to the manufacturer's instructions. The correlation will be quantified using a Pearson or Spearman correlation coefficient, as appropriate based on data distribution. |
At enrollment
|
|
Area Under the ROC Curve for Metrnl in Distinguishing Peri-Implantitis From Peri-Implant Health
Prazo: At enrollment
|
Metrnl concentration in peri-implant crevicular fluid will be quantified using a commercially available enzyme-linked immunosorbent assay (ELISA) kit (Shanghai Sunred Biological Technology Co., Ltd., Shanghai, China) and expressed in ng/mL. Its diagnostic ability to distinguish peri-implantitis from peri-implant health will be evaluated using receiver operating characteristic (ROC) curve analysis. Diagnostic performance will be quantified by the area under the ROC curve (AUC), a unitless measure ranging from 0 to 1. |
At enrollment
|
|
Correlation Between Metrnl and TNF-α Concentrations in Peri-Implant Crevicular Fluid
Prazo: At enrollment
|
The correlation between Metrnl concentration (ng/mL) and TNF-α concentration (pg/mL) in peri-implant crevicular fluid will be evaluated. Both biomarkers will be quantified using commercially available enzyme-linked immunosorbent assay (ELISA) kits (Shanghai Sunred Biological Technology Co., Ltd., Shanghai, China) according to the manufacturer's instructions. The correlation will be quantified using a Pearson or Spearman correlation coefficient, as appropriate based on data distribution. |
At enrollment
|
|
Correlation Between Metrnl and IL-10 Concentrations in Peri-Implant Crevicular Fluid
Prazo: At enrollment
|
The correlation between Metrnl concentration (ng/mL) and IL-10 concentration (pg/mL) in peri-implant crevicular fluid will be evaluated. Both biomarkers will be quantified using commercially available enzyme-linked immunosorbent assay (ELISA) kits (Shanghai Sunred Biological Technology Co., Ltd., Shanghai, China) according to the manufacturer's instructions. The correlation will be quantified using a Pearson or Spearman correlation coefficient, as appropriate based on data distribution. |
At enrollment
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Diretor de estudo: Recep Orbak, DDS, PhD, Ataturk University
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- 758
- 15367 (Número de outro subsídio/financiamento: Atatürk University Scientific Research Projects Coordination Unit)
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .