- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07698977
Inhibition of Myopia Progression With Optical Devices
This observational study aims to determine whether optical devices designed to slow myopia progression and/or environmental factors can prevent myopia progression in the pediatric and adolescent myopic population.
The study aims to answer the following questions:
- How does myopia progression change with age while wearing myopia progression control glasses?
- How does myopia progression change while wearing myopia progression-control glasses when environmental factors, such as time spent outdoors and place of residence, are taken into account?
- How does myopia progression change at different ages while wearing myopia progression control glasses given a family history of myopia? This will be a self-controlled observational study. Participants who are myopic after cycloplegic refraction will be prescribed DIMS glasses. DIMS stands for "defocus incorporated multiple segments," a specialized optical technology used in spectacle lenses to slow nearsightedness progression in children.
Patients will keep a diary of their subjective symptoms and environmental factors, e.g., time spent outdoors and screen time.
Patients will visit the clinic once every six months for checkups and the following tests:
- Best corrected visual acuity test
- Stereopsis
- Automatic refractometry
- Bulbar axial length measurement
In a follow-up study, researchers will compare myopia progression with environmental and baseline factors to learn about the long-term effects of DIMS lenses on myopia progression.
Aperçu de l'étude
Statut
Description détaillée
As an observational study we aim to examine the effects of D.I.M.S. lens's daily wear on myopia progression in relation to the environmental factors.
Our pediatric and adolescent myopic population is selected as follows:
Inclusion Criteria:
- Participants must be between 6 and 15 years of age at the start of myopia progression treatment
- Caucasian ethnicity
- Refractive error measured under cycloplegia, expressed as spherical equivalent: between -0.50 Dsph and -10.0 Dsph
- Wearing myopia-control glasses during waking hours
- Willing to Participate in follow-up examinations up to 24 weeks
Exclusion criteria:
- pathological myopia (e.g., myopia onset before age 6, Stickler syndrome)
- preterm infants born before 32 weeks of gestation
- previous eye-opening surgery (e.g., lens extraction)
- Traumatic eye injury
- Known connective tissue disorder (e.g., Marfan syndrome)
- Irregular or improper use of progressive-lens glasses
- Failure to attend the follow-up examinations scheduled
In the self-controlled observational study the myopic participants are wearing during day time DIMS glasses. DIMS stands for "defocus incorporated multiple segments," a specialized optical technology used in spectacle lenses to slow nearsightedness progression in children. DIMS glasses not only correct the refractive errror but also provide a circular defocus zone to avoid periferial retinal defocus.
Patients will keep a diary of their subjective symptoms and environmental factors, e.g., time spent outdoors and screen time, subjective symptoms.
Patients will visit the clinic once every six months for checkups and the following tests:
- Best corrected visual acuity test
- Stereopsis
- Automatic refractometry
- Bulbar axial length measurement These measurements and tests are part of the regular ophthalmological follow-up examinations.
The study aims to answer the following questions:
- How does myopia progression change with age while wearing myopia progression control glasses?
- How does myopia progression change while wearing myopia progression-control glasses when environmental factors, such as time spent outdoors and place of residence, are taken into account?
- How does myopia progression change at different ages while wearing myopia progression control glasses given a family history of myopia? Statistical analysis plan includes non-parametric t-test, one way and two way ANOVA tests.
Type d'étude
Inscription (Estimé)
Contacts et emplacements
Coordonnées de l'étude
- Nom: Zoltan Zs Nagy, Professor
- Numéro de téléphone: +3614591500
- E-mail: szem.titkarsag@gmail.com
Sauvegarde des contacts de l'étude
- Nom: Amarilla Barcsay-Veres
- Numéro de téléphone: +3614591500
- E-mail: veres.amarilla@semmelweis.hu
Lieux d'étude
-
-
-
Budapest, Hongrie, 1085
- Recrutement
- Semmelweis University Ophthalmology Department
-
Contact:
- Zoltan Zs Nagy, Professor
- Numéro de téléphone: +3614591500
- E-mail: szem.titkarsag@semmelweis.hu
-
Contact:
- Amarilla Barcsay-Veres, PhD
- Numéro de téléphone: +3614591500
- E-mail: veres.amarilla@semmelweis.hu
-
Sous-enquêteur:
- Otto A Maneschg, PhD
-
Sous-enquêteur:
- Amarilla Barcsay-Veres, PhD
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Enfant
Accepte les volontaires sains
Méthode d'échantillonnage
Population étudiée
Participants (between 6 and 15 years of age) are wearing myopia progression treatment , namely D.I.M.S. lenses while they are awake. The wear these glasses to correct refractive error and to slow down myopia progression.
At enrollment the refractive error measured under cycloplegia, expressed as spherical equivalent must be: between -0.50 Dsph and -10.0 Dsph.
La description
Inclusion Criteria:
• Participants must be between 6 and 15 years of age at the start of myopia progression treatment
- Caucasian ethnicity
- Refractive error measured under cycloplegia, expressed as spherical equivalent: between -0.50 Dsph and -10.0 Dsph
- Wearing myopia-control glasses while awake
- Participation in follow-up examinations every 6 months
Exclusion Criteria:
• Pathological myopia (e.g., myopia onset before age 6, Stickler syndrome)
- Premature birth before the 32nd week of gestation
- Previous eye-opening surgery (e.g., lens removal)
- Traumatic eye injury
- Known connective tissue disorder (e.g., Marfan syndrome)
- Irregular or improper use of progressive-lens glasses
- Failure to attend the follow-up examinations scheduled every 6 months
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Cohortes et interventions
Groupe / Cohorte |
Intervention / Traitement |
|---|---|
|
Myopic cohort
Inclusion Criteria:
Exclusion criteria:
|
DIMS (Defocus Incorporated Multiple Segments) lenses wearing while awake
D.I.M.S. lenses are worn like normal glasses to correct myopia and, beyond that, their special design is intended to slow myopia progression via defocus lenslets.
There is targeted myopic defocus produced by the mid-peripheral lenslets with positive power to inhibit eye length growth.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Best corrected visual acuity test
Délai: up to 24 week
|
Zero is equivalent to no vision and 1.0 indicates the best visual acuity in decimal scale.
Distance and near visual acuity is measured under standard conditions
|
up to 24 week
|
|
Bulbar axial length measurement
Délai: up to 24 week
|
It is defined as the distance from the anterior surface of the cornea to the retinal pigment epithelium, measured in millimeters using optical device.
An increase in axial length is characteristic of the elongation of the eye.
|
up to 24 week
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Stereopsis
Délai: up to 24 week
|
stereopsis test (depth perception test) measures how well the eyes create three-dimensional vision.
The precision of depth perception is measured in seconds of arc (arcsec) using a test plate.
If stereoscopic vision is present, the smaller the angle, the more refined the stereopsis.
|
up to 24 week
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Zoltan Zs Nagy, Professor, Semmelweis University Ophthalmology Department
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- SE-RKEB 222/2026
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .