Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Inhibition of Myopia Progression With Optical Devices

7 de julho de 2026 atualizado por: Barcsay-Veres Amarilla, Semmelweis University

This observational study aims to determine whether optical devices designed to slow myopia progression and/or environmental factors can prevent myopia progression in the pediatric and adolescent myopic population.

The study aims to answer the following questions:

  1. How does myopia progression change with age while wearing myopia progression control glasses?
  2. How does myopia progression change while wearing myopia progression-control glasses when environmental factors, such as time spent outdoors and place of residence, are taken into account?
  3. How does myopia progression change at different ages while wearing myopia progression control glasses given a family history of myopia? This will be a self-controlled observational study. Participants who are myopic after cycloplegic refraction will be prescribed DIMS glasses. DIMS stands for "defocus incorporated multiple segments," a specialized optical technology used in spectacle lenses to slow nearsightedness progression in children.

Patients will keep a diary of their subjective symptoms and environmental factors, e.g., time spent outdoors and screen time.

Patients will visit the clinic once every six months for checkups and the following tests:

  • Best corrected visual acuity test
  • Stereopsis
  • Automatic refractometry
  • Bulbar axial length measurement

In a follow-up study, researchers will compare myopia progression with environmental and baseline factors to learn about the long-term effects of DIMS lenses on myopia progression.

Visão geral do estudo

Descrição detalhada

As an observational study we aim to examine the effects of D.I.M.S. lens's daily wear on myopia progression in relation to the environmental factors.

Our pediatric and adolescent myopic population is selected as follows:

Inclusion Criteria:

  • Participants must be between 6 and 15 years of age at the start of myopia progression treatment
  • Caucasian ethnicity
  • Refractive error measured under cycloplegia, expressed as spherical equivalent: between -0.50 Dsph and -10.0 Dsph
  • Wearing myopia-control glasses during waking hours
  • Willing to Participate in follow-up examinations up to 24 weeks

Exclusion criteria:

  • pathological myopia (e.g., myopia onset before age 6, Stickler syndrome)
  • preterm infants born before 32 weeks of gestation
  • previous eye-opening surgery (e.g., lens extraction)
  • Traumatic eye injury
  • Known connective tissue disorder (e.g., Marfan syndrome)
  • Irregular or improper use of progressive-lens glasses
  • Failure to attend the follow-up examinations scheduled

In the self-controlled observational study the myopic participants are wearing during day time DIMS glasses. DIMS stands for "defocus incorporated multiple segments," a specialized optical technology used in spectacle lenses to slow nearsightedness progression in children. DIMS glasses not only correct the refractive errror but also provide a circular defocus zone to avoid periferial retinal defocus.

Patients will keep a diary of their subjective symptoms and environmental factors, e.g., time spent outdoors and screen time, subjective symptoms.

Patients will visit the clinic once every six months for checkups and the following tests:

  • Best corrected visual acuity test
  • Stereopsis
  • Automatic refractometry
  • Bulbar axial length measurement These measurements and tests are part of the regular ophthalmological follow-up examinations.

The study aims to answer the following questions:

  1. How does myopia progression change with age while wearing myopia progression control glasses?
  2. How does myopia progression change while wearing myopia progression-control glasses when environmental factors, such as time spent outdoors and place of residence, are taken into account?
  3. How does myopia progression change at different ages while wearing myopia progression control glasses given a family history of myopia? Statistical analysis plan includes non-parametric t-test, one way and two way ANOVA tests.

Tipo de estudo

Observacional

Inscrição (Estimado)

50

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Estude backup de contato

Locais de estudo

      • Budapest, Hungria, 1085
        • Recrutamento
        • Semmelweis University Ophthalmology Department
        • Contato:
        • Contato:
        • Subinvestigador:
          • Otto A Maneschg, PhD
        • Subinvestigador:
          • Amarilla Barcsay-Veres, PhD

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Filho

Aceita Voluntários Saudáveis

Não

Método de amostragem

Amostra de Probabilidade

População do estudo

Participants (between 6 and 15 years of age) are wearing myopia progression treatment , namely D.I.M.S. lenses while they are awake. The wear these glasses to correct refractive error and to slow down myopia progression.

At enrollment the refractive error measured under cycloplegia, expressed as spherical equivalent must be: between -0.50 Dsph and -10.0 Dsph.

Descrição

Inclusion Criteria:

  • • Participants must be between 6 and 15 years of age at the start of myopia progression treatment

    • Caucasian ethnicity
    • Refractive error measured under cycloplegia, expressed as spherical equivalent: between -0.50 Dsph and -10.0 Dsph
    • Wearing myopia-control glasses while awake
    • Participation in follow-up examinations every 6 months

Exclusion Criteria:

  • • Pathological myopia (e.g., myopia onset before age 6, Stickler syndrome)

    • Premature birth before the 32nd week of gestation
    • Previous eye-opening surgery (e.g., lens removal)
    • Traumatic eye injury
    • Known connective tissue disorder (e.g., Marfan syndrome)
    • Irregular or improper use of progressive-lens glasses
    • Failure to attend the follow-up examinations scheduled every 6 months

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

Coortes e Intervenções

Grupo / Coorte
Intervenção / Tratamento
Myopic cohort

Inclusion Criteria:

  • Participants must be between 6 and 15 years of age at the start of myopia progression treatment
  • Caucasian ethnicity
  • Refractive error measured under cycloplegia, expressed as spherical equivalent: between -0.50 Dsph and -10.0 Dsph
  • Wearing myopia-control glasses while awake
  • Participation in follow-up examinations every 6 months

Exclusion criteria:

  • Pathological myopia (e.g., myopia onset before age 6, Stickler syndrome)
  • Premature birth before the 32nd week of gestation
  • Previous eye-opening surgery (e.g., lens removal)
  • Traumatic eye injury
  • Known connective tissue disorder (e.g., Marfan syndrome)
  • Irregular or improper use of progressive-lens glasses
  • Failure to attend the follow-up examinations scheduled every 6 months
DIMS (Defocus Incorporated Multiple Segments) lenses wearing while awake
D.I.M.S. lenses are worn like normal glasses to correct myopia and, beyond that, their special design is intended to slow myopia progression via defocus lenslets. There is targeted myopic defocus produced by the mid-peripheral lenslets with positive power to inhibit eye length growth.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Best corrected visual acuity test
Prazo: up to 24 week
Zero is equivalent to no vision and 1.0 indicates the best visual acuity in decimal scale. Distance and near visual acuity is measured under standard conditions
up to 24 week
Bulbar axial length measurement
Prazo: up to 24 week
It is defined as the distance from the anterior surface of the cornea to the retinal pigment epithelium, measured in millimeters using optical device. An increase in axial length is characteristic of the elongation of the eye.
up to 24 week

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Stereopsis
Prazo: up to 24 week
stereopsis test (depth perception test) measures how well the eyes create three-dimensional vision. The precision of depth perception is measured in seconds of arc (arcsec) using a test plate. If stereoscopic vision is present, the smaller the angle, the more refined the stereopsis.
up to 24 week

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Investigadores

  • Investigador principal: Zoltan Zs Nagy, Professor, Semmelweis University Ophthalmology Department

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

2 de junho de 2026

Conclusão Primária (Estimado)

31 de maio de 2027

Conclusão do estudo (Estimado)

31 de maio de 2027

Datas de inscrição no estudo

Enviado pela primeira vez

27 de junho de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

7 de julho de 2026

Primeira postagem (Real)

13 de julho de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

13 de julho de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

7 de julho de 2026

Última verificação

1 de julho de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • SE-RKEB 222/2026

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

INDECISO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Sim

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever