Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

A Study of Full-Spectrum Screen Lighting for Reducing Screen-Related Eye Fatigue and Dry Eye

16 septembre 2026 mis à jour par: Zhongshan Ophthalmic Center, Sun Yat-sen University

A Randomized Controlled Trial of the Effects of Full-Spectrum Screen Bar Lighting on Visual Fatigue and Dry Eye After a Standardized Screen Task

This study will evaluate whether full-spectrum screen bar lighting can reduce eye fatigue and dry eye symptoms after a standardized screen task. Prolonged screen use is common in daily work and study and may cause blurred vision, eye soreness, dryness, headache, and reduced attention. Light environment may be one way to improve visual comfort during screen use, but more controlled clinical evidence is needed.

In this randomized, parallel-group controlled study, 112 healthy adult participants will be assigned to either a full-spectrum screen bar lighting group or a brightness-matched control group without screen bar lighting. Participants in both groups will complete an approximately 2-hour standardized screen task in a controlled laboratory environment. The study will compare changes before and after the task in objective and subjective measures of visual fatigue and dry eye, including critical flicker fusion frequency, visual fatigue questionnaire scores, eye movement and blinking parameters, pupil parameters, tear film-related measurements, and dry eye symptom scores. Safety and discomfort during the study will also be recorded.

Aperçu de l'étude

Description détaillée

Prolonged use of electronic screens is increasingly common in work, study, and daily life and may lead to visual fatigue and dry eye-related symptoms. These symptoms may include blurred vision, eye soreness, dryness, headache, and reduced attention. Although behavioral strategies such as taking breaks and adjusting viewing distance are commonly recommended, their effectiveness may be limited by individual adherence. Optimizing the lighting environment during screen use may provide a standardized and practical approach to improving visual comfort.

This is a single-center, randomized, parallel-group controlled study designed to evaluate the effects of full-spectrum screen bar lighting during a standardized screen task. Eligible healthy adult participants with regular daily screen exposure will be randomly assigned in a 1:1 ratio to either a full-spectrum screen bar lighting group or a brightness-matched control group without screen bar lighting. Both groups will complete the same approximately 2-hour standardized screen task in a controlled laboratory environment. The task may include computer-based text processing, screen reading, or viewing specified video materials, with the task content, duration, and completion requirements kept consistent between groups.

Assessments will be performed before and immediately after the standardized screen task. The study will evaluate changes in objective and subjective measures of visual fatigue, ocular behavioral parameters, and dry eye-related indicators. These include critical flicker fusion frequency, visual fatigue questionnaire scores, eye movement, blinking and pupil parameters, tear film-related measurements, conjunctival redness, and dry eye symptom scores. Safety will be assessed by recording any discomfort or adverse events, such as glare discomfort, eye dryness, tearing, conjunctival redness, headache, nausea, or dizziness.

This study is expected to provide clinical evidence on whether full-spectrum screen bar lighting can help reduce screen-related visual fatigue and dry eye symptoms, and may support the development of lighting strategies for visual health in daily screen-use environments.

Type d'étude

Interventionnel

Inscription (Estimé)

112

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Guangdong
      • Guangzhou, Guangdong, Chine, 510060
        • Zhongshan Ophthalmic Center

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte

Accepte les volontaires sains

Oui

La description

Inclusion Criteria:

  1. Age 18 to 35 years, male or female.
  2. Average daily electronic screen exposure of at least 4 hours.
  3. Near visual acuity at 40 cm of 0.5 or better, and able to complete the study 1. tasks and measurements stably.
  4. Able and willing to provide written informed consent.

Exclusion Criteria:

  1. Presence of ocular inflammation or ocular disease.
  2. History of severe systemic disease, neurological disease, or psychiatric disorder.
  3. Use of dry eye or visual fatigue treatments, or contact lens wear, within 1 month before the study.
  4. History of ocular surgery within the past 6 months.
  5. Daily use of lenses with blue-light blocking, photochromic, polarized, filtering, or similar optical functions.
  6. Professional background in ophthalmology or optical products.
  7. Intake of caffeine or other stimulants within 4 hours before the study.
  8. Best-corrected visual acuity (BCVA) less than 0.8.
  9. Anisometropia of 1.00 diopter or greater, or astigmatism of ±2.00 diopters or greater.
  10. Intraocular pressure (IOP) less than 5 mmHg or greater than 21 mmHg.
  11. Non-invasive tear breakup time (NIBUT) less than 5 seconds in either eye.
  12. Ocular Surface Disease Index (OSDI) score of 33 or greater.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: La prévention
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Seul

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Full-Spectrum Screen Bar Lighting
Participants assigned to this arm will complete an approximately 2-hour standardized screen task in a controlled laboratory environment using a full-spectrum screen bar light (MB23001032H-1B) as task lighting. The screen task may include computer-based text processing, screen reading, or viewing specified video materials. Task content, duration, and completion requirements will be kept consistent with the control arm.
The full-spectrum screen bar light will be used as task lighting during an approximately 2-hour standardized screen task in a controlled laboratory environment. Participants will complete computer-based text processing, screen reading, or viewing of specified video materials to simulate prolonged near-screen use.
Comparateur placebo: Brightness-Matched Control
Participants assigned to this arm will complete the same approximately 2-hour standardized screen task in the same controlled laboratory environment without using a full-spectrum screen bar light or any additional screen bar lighting. Screen brightness will be adjusted to match the brightness condition of the full-spectrum screen bar lighting arm. Task content, duration, and completion requirements will be kept consistent with the experimental arm.
Participants will complete the standardized screen task without using a screen bar light. Screen brightness will be adjusted to match the brightness condition of the full-spectrum screen bar lighting arm. The task type, content, duration, and completion requirements will be the same as those in the experimental arm.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Change in Critical Flicker Fusion Frequency
Délai: Baseline and immediately after completion of the approximately 2-hour standardized screen task
Critical flicker fusion frequency (CFF) will be measured in Hz using the Handy Flicker HF-III device. The outcome will be calculated as the post-task CFF value minus the baseline CFF value. This measure will be used as an objective indicator of visual fatigue after the standardized screen task.
Baseline and immediately after completion of the approximately 2-hour standardized screen task

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Change in Computer Vision Syndrome Questionnaire Score
Délai: Baseline and immediately after completion of the approximately 2-hour standardized screen task
The Computer Vision Syndrome Questionnaire (CVS-Q) will be used to assess subjective visual fatigue symptoms. The outcome will be calculated as the post-task total score minus the baseline total score.
Baseline and immediately after completion of the approximately 2-hour standardized screen task
Change in EyeFatigue Tracker Ocular Behavioral Parameters
Délai: Baseline and immediately after completion of the approximately 2-hour standardized screen task
Ocular behavioral parameters will be recorded using the EyeFatigue Tracker system during a standardized 1-minute reading task. The assessment will include eye movement, blink, and pupil-related parameters. Change values will be calculated as post-task values minus baseline values.
Baseline and immediately after completion of the approximately 2-hour standardized screen task
Change in Keratograph 5M Ocular Surface Assessment
Délai: Baseline and immediately after completion of the approximately 2-hour standardized screen task
Objective ocular surface and dry eye-related parameters will be measured using the Keratograph 5M system. The assessment will include non-invasive tear breakup time, tear meniscus height, and conjunctival redness. Change values will be calculated as post-task values minus baseline values.
Baseline and immediately after completion of the approximately 2-hour standardized screen task
Change in Eye Dryness Score on the 0-100 Visual Analog Scale
Délai: Baseline and immediately after completion of the approximately 2-hour standardized screen task
Eye dryness will be assessed using the Eye Dryness Score on a 0-100 visual analog scale. Participants will indicate the severity of eye dryness by placing a mark on a 100-mm horizontal line, where 0 represents no eye dryness and 100 represents the most severe eye dryness. Higher scores indicate worse symptoms. The change score will be calculated as the score immediately after the standardized screen task minus the baseline score. A positive change indicates worsening of eye dryness, whereas a negative change indicates improvement.
Baseline and immediately after completion of the approximately 2-hour standardized screen task

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Estimé)

22 septembre 2026

Achèvement primaire (Estimé)

1 avril 2027

Achèvement de l'étude (Estimé)

1 avril 2027

Dates d'inscription aux études

Première soumission

9 juillet 2026

Première soumission répondant aux critères de contrôle qualité

9 juillet 2026

Première publication (Réel)

15 juillet 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

18 septembre 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

16 septembre 2026

Dernière vérification

1 septembre 2026

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner