Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

A Study of Full-Spectrum Screen Lighting for Reducing Screen-Related Eye Fatigue and Dry Eye

20 lipca 2026 zaktualizowane przez: Zhongshan Ophthalmic Center, Sun Yat-sen University

A Randomized Controlled Trial of the Effects of Full-Spectrum Screen Bar Lighting on Visual Fatigue and Dry Eye After a Standardized Screen Task

This study will evaluate whether full-spectrum screen bar lighting can reduce eye fatigue and dry eye symptoms after a standardized screen task. Prolonged screen use is common in daily work and study and may cause blurred vision, eye soreness, dryness, headache, and reduced attention. Light environment may be one way to improve visual comfort during screen use, but more controlled clinical evidence is needed.

In this randomized, parallel-group controlled study, 112 healthy adult participants will be assigned to either a full-spectrum screen bar lighting group or a brightness-matched control group without screen bar lighting. Participants in both groups will complete an approximately 2-hour standardized screen task in a controlled laboratory environment. The study will compare changes before and after the task in objective and subjective measures of visual fatigue and dry eye, including critical flicker fusion frequency, visual fatigue questionnaire scores, eye movement and blinking parameters, pupil parameters, tear film-related measurements, and dry eye symptom scores. Safety and discomfort during the study will also be recorded.

Przegląd badań

Szczegółowy opis

Prolonged use of electronic screens is increasingly common in work, study, and daily life and may lead to visual fatigue and dry eye-related symptoms. These symptoms may include blurred vision, eye soreness, dryness, headache, and reduced attention. Although behavioral strategies such as taking breaks and adjusting viewing distance are commonly recommended, their effectiveness may be limited by individual adherence. Optimizing the lighting environment during screen use may provide a standardized and practical approach to improving visual comfort.

This is a single-center, randomized, parallel-group controlled study designed to evaluate the effects of full-spectrum screen bar lighting during a standardized screen task. Eligible healthy adult participants with regular daily screen exposure will be randomly assigned in a 1:1 ratio to either a full-spectrum screen bar lighting group or a brightness-matched control group without screen bar lighting. Both groups will complete the same approximately 2-hour standardized screen task in a controlled laboratory environment. The task may include computer-based text processing, screen reading, or viewing specified video materials, with the task content, duration, and completion requirements kept consistent between groups.

Assessments will be performed before and immediately after the standardized screen task. The study will evaluate changes in objective and subjective measures of visual fatigue, ocular behavioral parameters, and dry eye-related indicators. These include critical flicker fusion frequency, visual fatigue questionnaire scores, eye movement, blinking and pupil parameters, tear film-related measurements, conjunctival redness, and dry eye symptom scores. Safety will be assessed by recording any discomfort or adverse events, such as glare discomfort, eye dryness, tearing, conjunctival redness, headache, nausea, or dizziness.

This study is expected to provide clinical evidence on whether full-spectrum screen bar lighting can help reduce screen-related visual fatigue and dry eye symptoms, and may support the development of lighting strategies for visual health in daily screen-use environments.

Typ studiów

Interwencyjne

Zapisy (Szacowany)

112

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Lokalizacje studiów

    • Guangdong
      • Guangzhou, Guangdong, Chiny, 510060
        • Zhongshan Ophthalmic Center

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

  • Dorosły

Akceptuje zdrowych ochotników

Tak

Opis

Inclusion Criteria:

  1. Age 18 to 35 years, male or female.
  2. Average daily electronic screen exposure of at least 4 hours.
  3. Near visual acuity at 40 cm of 0.5 or better, and able to complete the study 1. tasks and measurements stably.
  4. Able and willing to provide written informed consent.

Exclusion Criteria:

  1. Presence of ocular inflammation or ocular disease.
  2. History of severe systemic disease, neurological disease, or psychiatric disorder.
  3. Pregnancy or lactation.
  4. Use of dry eye or visual fatigue treatments, or contact lens wear, within 1 month before the study.
  5. History of ocular surgery within the past 6 months.
  6. Daily use of lenses with blue-light blocking, photochromic, polarized, filtering, or similar optical functions.
  7. Professional background in ophthalmology or optical products.
  8. Intake of caffeine or other stimulants within 4 hours before the study.
  9. Best-corrected visual acuity (BCVA) less than 0.8.
  10. Anisometropia of 1.00 diopter or greater, or astigmatism of ±2.00 diopters or greater.
  11. Intraocular pressure (IOP) less than 5 mmHg or greater than 21 mmHg.
  12. Non-invasive tear breakup time (NIBUT) less than 5 seconds in either eye.
  13. Ocular Surface Disease Index (OSDI) score of 33 or greater.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Zapobieganie
  • Przydział: Randomizowane
  • Model interwencyjny: Przydział równoległy
  • Maskowanie: Pojedynczy

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Eksperymentalny: Full-Spectrum Screen Bar Lighting
Participants assigned to this arm will complete an approximately 2-hour standardized screen task in a controlled laboratory environment using a full-spectrum screen bar light (MB23001032H-1B) as task lighting. The screen task may include computer-based text processing, screen reading, or viewing specified video materials. Task content, duration, and completion requirements will be kept consistent with the control arm.
The full-spectrum screen bar light will be used as task lighting during an approximately 2-hour standardized screen task in a controlled laboratory environment. Participants will complete computer-based text processing, screen reading, or viewing of specified video materials to simulate prolonged near-screen use.
Komparator placebo: Brightness-Matched Control
Participants assigned to this arm will complete the same approximately 2-hour standardized screen task in the same controlled laboratory environment without using a full-spectrum screen bar light or any additional screen bar lighting. Screen brightness will be adjusted to match the brightness condition of the full-spectrum screen bar lighting arm. Task content, duration, and completion requirements will be kept consistent with the experimental arm.
Participants will complete the standardized screen task without using a screen bar light. Screen brightness will be adjusted to match the brightness condition of the full-spectrum screen bar lighting arm. The task type, content, duration, and completion requirements will be the same as those in the experimental arm.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Change in Critical Flicker Fusion Frequency
Ramy czasowe: Baseline and immediately after completion of the approximately 2-hour standardized screen task
Critical flicker fusion frequency (CFF) will be measured in Hz using the Handy Flicker HF-III device. The outcome will be calculated as the post-task CFF value minus the baseline CFF value. This measure will be used as an objective indicator of visual fatigue after the standardized screen task.
Baseline and immediately after completion of the approximately 2-hour standardized screen task

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Change in Computer Vision Syndrome Questionnaire Score
Ramy czasowe: Baseline and immediately after completion of the approximately 2-hour standardized screen task
The Computer Vision Syndrome Questionnaire (CVS-Q) will be used to assess subjective visual fatigue symptoms. The outcome will be calculated as the post-task total score minus the baseline total score.
Baseline and immediately after completion of the approximately 2-hour standardized screen task
Change in EyeFatigue Tracker Ocular Behavioral Parameters
Ramy czasowe: Baseline and immediately after completion of the approximately 2-hour standardized screen task
Ocular behavioral parameters will be recorded using the EyeFatigue Tracker system during a standardized 1-minute reading task. The assessment will include eye movement, blink, and pupil-related parameters. Change values will be calculated as post-task values minus baseline values.
Baseline and immediately after completion of the approximately 2-hour standardized screen task
Change in Keratograph 5M Ocular Surface Assessment
Ramy czasowe: Baseline and immediately after completion of the approximately 2-hour standardized screen task
Objective ocular surface and dry eye-related parameters will be measured using the Keratograph 5M system. The assessment will include non-invasive tear breakup time, tear meniscus height, and conjunctival redness. Change values will be calculated as post-task values minus baseline values.
Baseline and immediately after completion of the approximately 2-hour standardized screen task
Change in Eye Dryness Score on the 0-100 Visual Analog Scale
Ramy czasowe: Baseline and immediately after completion of the approximately 2-hour standardized screen task
Eye dryness will be assessed using the Eye Dryness Score on a 0-100 visual analog scale. Participants will indicate the severity of eye dryness by placing a mark on a 100-mm horizontal line, where 0 represents no eye dryness and 100 represents the most severe eye dryness. Higher scores indicate worse symptoms. The change score will be calculated as the score immediately after the standardized screen task minus the baseline score. A positive change indicates worsening of eye dryness, whereas a negative change indicates improvement.
Baseline and immediately after completion of the approximately 2-hour standardized screen task

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Publikacje i pomocne linki

Osoba odpowiedzialna za wprowadzenie informacji o badaniu dobrowolnie udostępnia te publikacje. Mogą one dotyczyć wszystkiego, co jest związane z badaniem.

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Szacowany)

20 lipca 2026

Zakończenie podstawowe (Szacowany)

31 grudnia 2026

Ukończenie studiów (Szacowany)

31 grudnia 2026

Daty rejestracji na studia

Pierwszy przesłany

9 lipca 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

9 lipca 2026

Pierwszy wysłany (Rzeczywisty)

15 lipca 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

22 lipca 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

20 lipca 2026

Ostatnia weryfikacja

1 lipca 2026

Więcej informacji

Terminy związane z tym badaniem

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIE

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Badania kliniczne na Wyschnięte oko

Badania kliniczne na Full-spectrum screen bar light

Subskrybuj