Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Micro-nanoplastic Exposure and Coronary Microcirculatory Dysfunction as Well as Cardiovascular Outcomes

19 août 2026 mis à jour par: Beijing Anzhen Hospital

Association of Micro-Nanoplastic Exposure With Coronary Microvascular Dysfunction and Subsequent Cardiovascular Outcomes: A Prospective Cohort Study

With strict quality control procedures applied throughout microplastic testing, this study will assess the association between baseline circulating micro-nanoplastic exposure and coronary microvascular dysfunction, as well as subsequent long-term cardiovascular outcomes.

Aperçu de l'étude

Description détaillée

Using a prospective cohort study design, this study will enroll patients with clinical indications scheduled for invasive coronary angiography and coronary functional assessment. With a two-tiered framework of "pre-intervention baseline exposure assessment + procedural contamination quantification", it will be the first study to systematically evaluate the dose-response relationship between circulating microplastics and nanoplastics (MNPs) levels and coronary microvascular dysfunction (CMD). Through 2 years of follow-up, the effect of MNPs on the long-term prognosis of patients with CMD will also be assessed.

Multi-modal omics technologies including pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS), laser direct infrared spectroscopy (LDIR), and scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM-EDS) will be applied for the qualitative and quantitative detection of MNPs. The index of microcirculatory resistance (IMR) and coronary flow reserve (CFR), measured via the invasive thermodilution method recommended by the European Society of Cardiology (ESC), will be used to define and evaluate CMD.

The core innovations of this protocol are twofold:

The key blood samples for exposure measurement are strictly collected before any medical procedures are performed after admission, to maximally eliminate the confounding bias from iatrogenic interference in baseline MNPs exposure quantification.

A three-level blank quality control system (procedural blank, environmental blank, device blank) is established to realize full-process monitoring and quantification of iatrogenic contamination.

The entire study design strictly adheres to current technical recommendations and industry consensus in clinical practice, and demonstrates high feasibility, reproducibility, and reliability.

Type d'étude

Observationnel

Inscription (Estimé)

184

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Non

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Patients older than 18 years old, with clinical indications for planned invasive coronary angiography and coronary functional assessment.

La description

Inclusion Criteria:

  • Age ≥ 18;
  • Patients with clinical indications for undergoing invasive coronary angiography and coronary functional assessment (including fractional flow reserve [FFR], CFR, and IMR);
  • Voluntarily sign the written informed consent form.

Exclusion Criteria:

  • The surgeon (or attending physician) determines that the patient is not suitable for or cannot tolerate a coronary physiological examination;
  • Intraoperative coronary angiography reveals a stenosis of>90% in any non-left main coronary artery lumen or a stenosis of>50% in the left main coronary artery lumen;
  • Left ventricular ejection fraction <35% or cardiogenic shock or cardiac arrest;
  • Previous history of invasive procedures/treatments;
  • Active inflammatory diseases;
  • Connective tissue disease;
  • History of malignant tumors;
  • Expected lifespan <2 years;
  • Pregnancy or lactation;
  • Subjects who refuse to comply with the pollution control measures set in this study;
  • Currently participating in other interventional clinical trials.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Cohortes et interventions

Groupe / Cohorte
Intervention / Traitement
Micro-nanoplastic Exposure and CVOT
According to the baseline circulating MNPs exposure level of the patients, participants will be categorized into the high-exposure group and low-exposure group using the median value as the cutoff point.
In this prospective cohort study, the investigators plan to perform a low-contamination protocol for the detection of circulating micro-nanoplastic particles in eligible subjects prior to the administration of invasive coronary angiography and concomitant coronary microvascular function assessment, so as to clarify the impact of micro-nanoplastic exposure status on coronary microvascular function and long-term prognosis.
Using a catheter to perform invasive coronary functional assessment, including flow fraction reserve(FFR), coronary flow reserve (CFR) and index of microcirculation resistance (IMR)

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Baseline Peripheral Circulatory MNPs Concentration(μg/g, particles/ml)
Délai: baseline
Using multi-modal omics methodologies (Py-GC/MS, LDIR, and SEM-EDS), the investigators will evaluate the correlation between the total baseline peripheral circulatory concentration of MNPs and the baseline concentration of each specific particle type (reported as mass concentration in μg/g and particle count in particles/mL) in peripheral circulating blood and coronary sinus blood, and baseline coronary microvascular function
baseline
Coronary Microvascular Function
Délai: baseline
Using invasive functional examinations (Coronary Flow Reverse, CFR and Index of Microcirculatory Resistance, IMR) to evaluate coronary microvascular function. Coronary Microvascular Dysfunction (CMD) is diagnosed by CFR<2.0 and IMR≥25.
baseline

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Baseline Intracoronary MNPs Concentration(μg/g, particles/ml)
Délai: Baseline
Using multi-modal omics methodologies (Py-GC/MS, LDIR, and SEM-EDS), the investigators will evaluate the correlation between the total baseline intracoronary concentration of MNPs and the baseline concentration of each specific particle type (reported as mass concentration in μg/g and particle count in particles/mL) in both peripheral circulating blood and coronary sinus blood, and baseline coronary microvascular function.
Baseline
2 years Follow-up MACE
Délai: 2 years
Major Adverse Cardiovascular Events (MACE) is defined as a composition endpoint including all-cause death, non-fatal stroke, non-fatal myocardial infarction, hospitalization due to unstable angina, or heart failure events
2 years

Autres mesures de résultats

Mesure des résultats
Description de la mesure
Délai
Baseline Peripheral MNPs Subpopulations
Délai: Baseline
Using multi-modal omics methodologies (Py-GC/MS, LDIR, SEM-EDS), the investigators will evaluate the correlations between CMD and multiple variables of MNPs in both peripheral circulating blood and coronary sinus blood, including MNP particle counts, morphological characteristics of each specific particle type (particle size, shape, polymer type, surface charge, etc.)
Baseline
Baseline Intracoronary MNPs Subpopulations
Délai: Baseline
Using multi-modal omics methodologies (Py-GC/MS, LDIR, SEM-EDS), the investigators will evaluate the correlations between CMD and multiple variables of MNPs in both peripheral circulating blood and coronary sinus blood, including MNP particle counts, morphological characteristics of each specific particle type (particle size, shape, polymer type, surface charge, etc.)
Baseline
Baseline Circulatory Inflammation Biomarkers
Délai: Baseline
Circulatory Inflammation Biomarkers includes interleukin-6 (IL-6), high-sensitivity C-reactive protein (hsCRP), procalcitonin (PCT), among other related molecular indicators.
Baseline

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Estimé)

1 janvier 2027

Achèvement primaire (Estimé)

31 décembre 2029

Achèvement de l'étude (Estimé)

31 décembre 2029

Dates d'inscription aux études

Première soumission

26 juillet 2026

Première soumission répondant aux critères de contrôle qualité

31 juillet 2026

Première publication (Réel)

6 août 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

21 août 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

19 août 2026

Dernière vérification

1 juillet 2026

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • MNPs-CMD

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner