Digital vs Conventional VFR in Post-Orthodontic Retention
Comparison of Periodontal Health Parameters Using Conventional Versus Digital Vacuum Formed Retainer (VFR).
This study is comparing two ways of making a retainer, the clear, removable kind worn after braces to see whether the way it's made affects gum health. One type is made using a digital scan of the teeth, and the other is made the traditional way, using a plaster mold. The study will look at how each type affects plaque buildup, gum swelling, and the depth of the space between the tooth and gum over a six-month period.
About 52 people who have just finished braces on both their upper and lower teeth will take part. Participants will be assigned to one of two groups: one group will receive a digitally made retainer, and the other will receive a traditionally made retainer.
Retainer Fitting Before the study begins, each participant's retainer is custom-made for their teeth, either from a digital scan or a plaster mold, depending on which group they're in. Participants will wear their retainer for 22 hours a day, taking it out only to eat and brush their teeth.
Daily Care Throughout the study, participants will follow the same tooth-brushing and gum-care routine, so that any differences seen between the two groups can be linked to the retainer itself rather than to differences in oral hygiene. Participants will be asked to avoid using mouthwash while wearing the retainer.
Check-Up Visits
Participants will attend four check-ups over six months:
Before the retainer is placed (baseline) One month after placement Three months after placement Six months after placement
At each visit, a dentist will check the teeth and gums for plaque buildup, gum swelling or bleeding, and pocket depth (the space between the tooth and gum) using a small measuring tool called a probe.
Follow-Up The final check-up at six months marks the end of the study for each participant. Participants can leave the study at any time if they choose.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Orthodontic retention is essential to prevent relapse following active orthodontic treatment, and vacuum-formed retainers (VFRs) are widely used due to their aesthetics and ease of fabrication.
Conventional VFRs are fabricated over a plaster model derived from alginate impressions, while digital VFRs are fabricated over a 3D-printed model generated from an intraoral scan.
This randomized clinical trial compares periodontal health outcomes; Plaque Index, Gingival Index, and Periodontal Pocket Depth, between the two fabrication methods.
Fifty-two participants (26 per arm) aged 15-30 years who have completed non-extraction fixed orthodontic treatment on both arches within the last month will be enrolled via non-probability consecutive sampling. Group A will receive digitally fabricated VFRs; Group B will receive conventionally fabricated VFRs, both made of 1.5 mm PETG material. Participants will wear retainers 22 hours daily and follow standardized oral hygiene instructions.
Periodontal parameters will be assessed on index teeth 16, 21, 31, and 46 at baseline (T0) and at 1, 3, and 6 months (T1-T3) post-placement. Gingival Index will follow the Loe and Silness method; Plaque Index will follow the Silness and Loe method; pocket depth will be measured with a UNC-15 probe at six sites per tooth.
Data will be analyzed in SPSS v27 using independent-sample t-tests/Mann-Whitney U tests for between-group comparisons and paired t-tests for within-group change from baseline, with stratification for age and gender as effect modifiers.
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
- Nom: Dr Syed Riaz Hashim Principal Investigator
- Numéro de téléphone: +92 3312763463
- E-mail: syed.hashim@zu.edu.pk
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Enfant
- Adulte
Accepte les volontaires sains
La description
INCLUSION CRITERIA
- Patients aged 15-30 years
- Patients with good oral and general health
- Patients in which both the arches were treated with fixed orthodontic treatment on a non-extraction basis completed within the last 1 month
- Patients with minimum 24 permanent teeth present
EXCLUSION CRITERIA
- Patients that are medically compromised due to a systemic disease
- Patients having periodontal disease before debonding
- Patients with severe and uncontrolled caries
- Patients having cleft palate or any other severe facial deformity
- Patients using drugs that have direct or indirect effect on the periodontal health such as phenytoin, cyclosporine etc.
- Patients that have a habit of chronic smoking
- Pregnant patients
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Autre
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Group A - Digital VFR
Participants receive a vacuum-formed retainer thermoformed over a 3D-printed model generated from intraoral scanning, worn 22 hours/day for 6 months.
|
PETG, 1.5 mm, fabricated via intraoral scan and 3D-printed model
|
|
Comparateur actif: Group B - Conventional VFR
Participants receive a vacuum-formed retainer thermoformed over a plaster model generated from alginate impressions, worn 22 hours/day for 6 months.
|
PETG, 1.5 mm, fabricated via alginate impression and plaster model
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Plaque Index
Délai: Baseline (T0), 1 month (T1), 3 months (T2), 6 months (T3).
|
(Silness and Loe method) 4-point scale (0-3) scored on four surfaces (facial, lingual, mesial, distal) of index teeth 16, 21, 31, 46
|
Baseline (T0), 1 month (T1), 3 months (T2), 6 months (T3).
|
|
Gingival Index
Délai: Baseline (T0), 1 month (T1), 3 months (T2), 6 months (T3).
|
(Loe and Silness method) 4-point scale (0-3) assessing inflammation and bleeding on four surfaces of index teeth 16, 21, 31, 46
|
Baseline (T0), 1 month (T1), 3 months (T2), 6 months (T3).
|
|
Periodontal Pocket Depth
Délai: Baseline (T0), 1 month (T1), 3 months (T2), 6 months (T3)
|
measured in mm with a UNC-15 probe at six sites per index tooth (mesiofacial, midfacial, distofacial, mesiolingual, midlingual, distolingual); deepest site recorded
|
Baseline (T0), 1 month (T1), 3 months (T2), 6 months (T3)
|
Collaborateurs et enquêteurs
Parrainer
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- ZU-ORTHO-VFR-2026-001
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .