- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07846553
Artificial Intelligence Versus Anesthesiology Residents in Chest X-Ray Interpretation
Comparison of the Diagnostic Performance of an Artificial Intelligence System and Anesthesiology Residents in Interpreting Posteroanterior Chest Radiographs
This observational study will compare how accurately anesthesiology residents and an artificial intelligence system (hChestXR) identify abnormalities on chest X-rays. Approximately 35 volunteer anesthesiology residents at Kayseri City Hospital will review the same set of 150 anonymized posteroanterior chest radiographs selected from the hospital imaging archive. The set will include normal images and images showing findings such as infiltration, atelectasis, and pleural effusion. Two radiologists will independently assess the images and resolve disagreements by consensus to establish the reference standard. Residents will not see the radiologists' assessments or the artificial intelligence results while interpreting the images. The study will measure diagnostic accuracy and other measures of diagnostic performance. No additional imaging, treatment, or change in patient care is planned.
Aperçu de l'étude
Statut
Les conditions
Description détaillée
This single-center, cross-sectional, observational diagnostic accuracy study will be coordinated by the Department of Anesthesiology and Reanimation at Kayseri City Hospital. Volunteer resident assessments will be collected prospectively using retrospectively selected chest radiographs. The observational model is classified as Other because this is a comparative multi-reader, multi-case assessment of a fixed image set, without longitudinal follow-up.
A dataset of 150 posteroanterior chest radiographs will be selected from the hospital PACS to represent normal findings, common thoracic abnormalities, and a limited number of atypical or diagnostically challenging cases. The distribution of findings will be balanced to avoid marked overrepresentation or underrepresentation of particular abnormalities. All patient-identifying information will be removed before assessment.
Two radiologists will independently evaluate each radiograph. Disagreements will be resolved through joint review and consensus. Their final assessments will serve as the reference standard. The same radiographs will be analyzed by the hChestXR artificial intelligence system and independently interpreted by approximately 35 anesthesiology residents who provide informed consent. Residents will record suspected findings using a predefined multiple-choice assessment form and will be blinded to the radiologist and artificial intelligence assessments. Resident training year will also be recorded.
Diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value will be calculated overall and by finding. Comparisons between resident and hChestXR performance will account for the paired image assessments and the multi-reader, multi-case structure of the data. McNemar testing will be used for appropriate paired comparisons, and analyses will account for variability across readers and radiographs. Agreement with the radiologist reference standard will be evaluated using Cohen's kappa. A multi-reader, multi-case approach will consider individual resident performance and variability across readers interpreting the same image set. Analyses will use SPSS version 31.0, with p < 0.05 considered statistically significant.
An a priori sample size calculation was performed to determine the number of resident readers. Assuming an absolute difference of 15 percentage points in diagnostic accuracy between anesthesiology residents and hChestXR, a standard deviation of 25 percentage points in reader-level accuracy, a two-sided significance level of 0.05, and 90% power, the required minimum sample size was 32 residents (standardized effect size, Cohen's d = 0.60). To allow for incomplete assessments or participant withdrawal, at least 35 anesthesiology residents are planned for enrollment. The 150 radiographs constitute the image dataset and are distinct from the enrolled resident participants.
The study involves no patient intervention. Resident assessment data will be coded and de-identified for analysis, and identifying information will remain confidential. The planned study period is October 15, 2026, through November 15, 2026. Ethics approval was granted by the Kayseri City Hospital Non-Interventional Clinical Research Ethics Committee on August 26, 2026 (decision number 1081).
Type d'étude
Inscription (Estimé)
Contacts et emplacements
Coordonnées de l'étude
- Nom: Çiğdem Ünal Kantekin, MD
- Numéro de téléphone: +90 505 443 30 56
- E-mail: drcgdm@hotmail.com
Sauvegarde des contacts de l'étude
- Nom: Yusuf Yılmaz, MD
- Numéro de téléphone: +90 555 538 30 94
- E-mail: doktoryusufyilmaz@gmail.com
Lieux d'étude
-
-
-
Kayseri, Turquie (Türkiye), 38080
- Kayseri City Hospital
-
Contact:
- Çiğdem Ünal Kantekin, MD
- Numéro de téléphone: +90 505 443 30 56
- E-mail: drcgdm@hotmail.com
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
Approximately 35 adult anesthesiology and reanimation residents working at Kayseri City Hospital who volunteer and provide written informed consent. Enrollment refers to resident readers, not to the 150 retrospectively selected, anonymized chest radiographs used as the assessment dataset.
La description
Inclusion Criteria:
- An anesthesiology and reanimation resident working at Kayseri City Hospital.
- Voluntarily agrees to participate in the study.
- Provides written informed consent.
- Agrees to evaluate the posteroanterior chest radiographs presented in the study.
Exclusion Criteria:
- Failure to complete the 150-radiograph assessment.
- Withdrawal of consent before completion of the assessment.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Modèles d'observation: OTHER
- Perspectives temporelles: CROSS_SECTIONAL
Cohortes et interventions
Groupe / Cohorte |
|---|
|
Anesthesiology Residents
Approximately 35 volunteer anesthesiology and reanimation residents at Kayseri City Hospital will independently interpret 150 anonymized posteroanterior chest radiographs using a predefined multiple-choice form. Residents will be blinded to radiologist assessments and hChestXR outputs. Their diagnostic performance will be compared with hChestXR analysis of the same images, using the consensus of two radiologists as the reference standard. The artificial intelligence system is an image-level comparator, not a separate participant cohort. No treatment is assigned and no patient care is changed. |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Diagnostic Accuracy for Detection of Thoracic Abnormalities
Délai: During completion of the 150-radiograph assessment, within the 1-month study period
|
Percentage of correctly classified image-finding pairs, calculated as (true positives + true negatives) / all evaluated image-finding classifications × 100, using the consensus of two radiologists as the reference standard. Accuracy will be calculated for each resident and for hChestXR overall and separately for each predefined thoracic finding. |
During completion of the 150-radiograph assessment, within the 1-month study period
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Sensitivity for Detection of Thoracic Abnormalities
Délai: During completion of the 150-radiograph assessment, within the 1-month study period
|
Percentage of reference-positive classifications correctly identified: true positives / (true positives + false negatives) × 100. Sensitivity will be calculated for residents and hChestXR overall and by finding, using the consensus of two radiologists as the reference standard. |
During completion of the 150-radiograph assessment, within the 1-month study period
|
|
Specificity for Detection of Thoracic Abnormalities
Délai: During completion of the 150-radiograph assessment, within the 1-month study period
|
Percentage of reference-negative classifications correctly identified: true negatives / (true negatives + false positives) × 100. Specificity will be calculated for residents and hChestXR overall and by finding, using the consensus of two radiologists as the reference standard. |
During completion of the 150-radiograph assessment, within the 1-month study period
|
|
Positive Predictive Value
Délai: During completion of the 150-radiograph assessment, within the 1-month study period
|
Percentage of positive classifications confirmed by the radiologist reference standard: true positives / (true positives + false positives) × 100. Calculated for residents and hChestXR overall and by finding within the constructed study dataset. |
During completion of the 150-radiograph assessment, within the 1-month study period
|
|
Negative Predictive Value
Délai: During completion of the 150-radiograph assessment, within the 1-month study period
|
Percentage of negative classifications confirmed by the radiologist reference standard: true negatives / (true negatives + false negatives) × 100. Calculated for residents and hChestXR overall and by finding within the constructed study dataset. |
During completion of the 150-radiograph assessment, within the 1-month study period
|
|
Agreement With the Radiologist Reference Standard
Délai: During completion of the 150-radiograph assessment, within the 1-month study period
|
Agreement of resident interpretations and hChestXR classifications with the consensus radiologist reference standard will be assessed using Cohen's kappa. Cohen's kappa will be calculated separately for each resident and for hChestXR, with resident results summarized across readers. Kappa ranges from -1 to 1; 1 indicates perfect agreement, 0 agreement expected by chance, and negative values less agreement than expected by chance. Individual reader results will be evaluated within the multi-reader, multi-case framework. |
During completion of the 150-radiograph assessment, within the 1-month study period
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Çiğdem Ünal Kantekin, MD, Kayseri City Hospital
Publications et liens utiles
Publications générales
- Nam JG, Park S, Hwang EJ, Lee JH, Jin KN, Lim KY, Vu TH, Sohn JH, Hwang S, Goo JM, Park CM. Development and Validation of Deep Learning-based Automatic Detection Algorithm for Malignant Pulmonary Nodules on Chest Radiographs. Radiology. 2019 Jan;290(1):218-228. doi: 10.1148/radiol.2018180237. Epub 2018 Sep 25.
- Colquitt J, Jordan M, Court R, Loveman E, Parr J, Ghosh I, Auguste P, Patel M, Stinton C. Artificial intelligence software for analysing chest X-ray images to identify suspected lung cancer: an evidence synthesis early value assessment. Health Technol Assess. 2024 Aug;28(50):1-75. doi: 10.3310/LKRT4721.
- Rajpurkar P, Irvin J, Ball RL, Zhu K, Yang B, Mehta H, Duan T, Ding D, Bagul A, Langlotz CP, Patel BN, Yeom KW, Shpanskaya K, Blankenberg FG, Seekins J, Amrhein TJ, Mong DA, Halabi SS, Zucker EJ, Ng AY, Lungren MP. Deep learning for chest radiograph diagnosis: A retrospective comparison of the CheXNeXt algorithm to practicing radiologists. PLoS Med. 2018 Nov 20;15(11):e1002686. doi: 10.1371/journal.pmed.1002686. eCollection 2018 Nov.
- Eisen LA, Berger JS, Hegde A, Schneider RF. Competency in chest radiography. A comparison of medical students, residents, and fellows. J Gen Intern Med. 2006 May;21(5):460-5. doi: 10.1111/j.1525-1497.2006.00427.x.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- KCH-PAAG-AI-2026-1081
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Description du régime IPD
Individual participant data will not be shared with third parties, in accordance with the confidentiality provisions of the study protocol. Data will be used for scientific analyses, and findings will be disseminated in aggregate through presentations and publications.
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .