Using Glucose Sensors to Prevent Hypoglycemia
Paradigm Real Time Continuous Glucose Monitoring Device for the Prevention of Hypoglycemia
Hypoglycemia is the most common complication of Type 1 diabetes particularly in those who strive for good glycemic control. In some patients there is a loss of awareness of hypoglycaemia so that the first manifestation of hypoglycaemia may be confusion or coma. Such a situation may carry risks that the patient may harm him or her self. Medtronic has recently developed a continuous glucose sensor that determines the glucose level every 3 minutes using a subcutaneous sensor and transmits the information to a remote device (Paradigm RT) that may be worn or left close by eg on a bedside table. The device may be programmed to alarm for a rapidly falling glucose or for low glucose levels.
We propose to use this in 16 patients with severe hypoglycemia as evidenced by a high HYPO score and see if we can decrease the number of hypoglycemic reactions and document this improvement with a better HYPO score.
調査の概要
詳細な説明
Sixteen patients with Type 1 diabetes (as defined by: onset under the age of 25, lean at time of onset, continuous insulin use, and/or history of ketoacidosis and C-peptide negative), with a HYPO score over the seventy-fifth percentile (>423), will be approached and offered the study.
The study will be conducted over a three month time-frame. The first month will be a run-in period for participants to collect four weeks of glucose readings and information about their hypoglycemic events. These records will be used to calculate the baseline modified HYPO score. Patients will be screened during the first month for thyroid disease, celiac disease and Addison's disease.
During the second month they will meet with the study nurse for an intensive instruction period on the use of the Paradigm RT sensor. They will spend this month practicing to use the sensor and confirming they can use it adequately.
During the final month they will wear the sensor and collect glucose and hypoglycemia records for calculation of the final modified HYPO score.
The end point will be the change from the baseline modified HYPO score to the final four week HYPO score and this would be used to identify any improvement.
研究の種類
入学 (予想される)
段階
- フェーズ 3
連絡先と場所
研究場所
-
-
Alberta
-
Edmonton、Alberta、カナダ、T6G 2B7
- University of Alberta Hospital
-
Edmonton、Alberta、カナダ、T6G 2S2
- University of Alberta
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Type 1 Diabetes Mellitus confirmed by C-peptide <0.10 nmol/L
- age 18 - 70 yrs.
- HYPO score >423
- normal TSH, serum cortisol and anti-transglutaminase (ATTG)
Exclusion Criteria:
- current diagnosis of cancer
- planning a pregnancy
- Inability to give informed consent
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:非ランダム化
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:B
|
Use glucose sensor to prevent episodes of severe hypoglycemia
他の名前:
|
|
介入なし:A
Run in period
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
時間枠 |
|---|---|
|
Decrease in HYPO score
時間枠:3 months
|
3 months
|
二次結果の測定
結果測定 |
時間枠 |
|---|---|
|
Number of episodes of severe hypoglycemia
時間枠:3 months
|
3 months
|
|
Number of patients who decide to continue using the device
時間枠:3 months
|
3 months
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Edmond A Ryan, MD、University of Alberta
出版物と役立つリンク
研究記録日
主要日程の研究
研究開始
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (見積もり)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。