In Vitro Detection of Tissue Abnormality
調査の概要
詳細な説明
Intraoperative real-time margin assessment of breast conserving surgeries can reduce the need for repeat operations due to cancer involved margins. Repeat operations result in excessive removal of benign tissue, increased risk for infection, slower healing and inferior cosmetic results. In the current standard of care, the status of the margins is determined by pathology only several days after surgery. An intraoperative assessment of the margins enables complete tumor excision in a single surgery.
The proposed randomized controlled study will evaluate the benefits of adding the ClearEdge imaging device to the Standard of Care (SoC) of margins assessment in breast conserving surgeries. The study will assess whether there is an improvement in the detection of cancer involved margins by measuring whether removal at the time of primary surgical treatment can reduce the need for repeat surgeries as compared to the SoC, which does not use the device.
ClearEdge is a CE marked device already been used in several hospitals in the UK. It was used in a prospective single arm and 2 phases clinical study. It was demonstrated that surgeons successfully used the device to identify cancer involved margins and that it can reduce the need for repeat surgeries by meeting the margins depth criteria to require repeat operations. European Journal of Oncology Surgery. 2016; 42 (12): 1834-1840. In addition, the device was clinically evaluated by several hospitals.
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
California
-
San Francisco、California、アメリカ、94117
- St. Mary's
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Patients aged 25-80 who are scheduled for surgical excision of tissue.
Exclusion Criteria:
- No prior history of surgery at location of current surgery.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Device image reading
Tissue images generated by the device are read by surgeons to determine if the tissue area under test has abnormal component or not.
When Images generated by the device are read by surgeons as abnormal an additional margin of tissue is removed.
The new margin is also imaged by the device to ensure complete tumor excision.
|
Measurements are obtained with test device on excised tissue.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
•Accuracy of LS BioPath TOUCH device compared to pathology
時間枠:1 week after surgery
|
Assess percentage of FP and FN of test device results compared to pathology results
|
1 week after surgery
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Michael Lagios, MD、St. Mary's Medical Center
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
- LSB-01
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。