In clinical application, especially in head-and-neck surgeries, the operators often change the position of children's head-neck for easy operating. Flexing the head resulted in the ETT moving towards the carina, and extension resulted in the tube being displaced in the opposite direction. Head and neck movement change the length of trachea as well: extending the head resulted in the extension of trachea, while flexing resulted in the opposite. Serious complications following from head and neck movement, such as accidental extubation and endobronchial intubation, threat children's life.
In pediatric anesthesia, insertion depth (cm) of orotracheal intubation equals to age/2+12, according to classic intubation formulae. The ETT will be put in the depth calculated by the classic formulae under general anesthesia. The distance of ETT-tip displacement and the length change of trachea will be measured as the head and neck placed as follows: fully extended, neutral position, or fully flexed. These three head and neck positions imitate the head-neck movement during those head-and-neck surgeries.
研究の種類
入学 (実際)
連絡先と場所
研究場所
-
-
Beijing
-
Beijing、Beijing、中国、102218
- Department of Anesthesia, Beijing Tsinghua Chang Gung Hospital
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
説明
Inclusion Criteria:
- subject has elective head-and-neck surgery schedule
- subject will have orotracheal intubation under general anesthesia
Exclusion Criteria:
- subject has malformations of the trachea or bronchus on chest X-ray
- subject has spinal deformity
- subject has difficulties in neck flexion or extension
- subject has neck pain
研究計画
研究はどのように設計されていますか?
デザインの詳細
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Distance of trachea carina (TC) to endotracheal tube (ETT) tip
時間枠:10min (time that the measurement need)
|
Measure the distance between trachea carina to the tip of ETT in three different neck-head positions: fully flexion, neutral positon and fully extension.
|
10min (time that the measurement need)
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Distance of tracheal length
時間枠:10min (time that the measurement need)
|
Tracheal length equals the distance between trachea carina (TC) to posterior vocal commissure.
Measure Tracheal length in three different neck-head positions: fully flexion, neutral positon and fully extension.
|
10min (time that the measurement need)
|
|
Serious complication of unexpected displacement of the endotracheal tube: accidental extubation
時間枠:intraoperative
|
When the operator put the child's neck into extension position, accidental extubation may occur, which can lead to hypoxia and asphyxia.
|
intraoperative
|
|
Serious complication of unexpected displacement of the endotracheal tube: endobronchial intubation.
時間枠:intraoperative
|
When the operator put the child's neck into flexion position, accidental endobronchial intubation may occur, which can lead to one-lung ventilation and pulmonary edema.
|
intraoperative
|
協力者と研究者
捜査官
- 主任研究者:SIYI YAN, MD、Beijing Tsinghua Chang Gung Hospital
出版物と役立つリンク
一般刊行物
- Dronen S, Chadwick O, Nowak R. Endotracheal tip position in the arrested patient. Ann Emerg Med. 1982 Feb;11(2):116-7. doi: 10.1016/s0196-0644(82)80328-4. No abstract available.
- McCoy EP, Russell WJ, Webb RK. Accidental bronchial intubation. An analysis of AIMS incident reports from 1988 to 1994 inclusive. Anaesthesia. 1997 Jan;52(1):24-31. doi: 10.1111/j.1365-2044.1997.007-az007.x.
- Mariano ER, Ramamoorthy C, Chu LF, Chen M, Hammer GB. A comparison of three methods for estimating appropriate tracheal tube depth in children. Paediatr Anaesth. 2005 Oct;15(10):846-51. doi: 10.1111/j.1460-9592.2005.01577.x.
- Lau N, Playfor SD, Rashid A, Dhanarass M. New formulae for predicting tracheal tube length. Paediatr Anaesth. 2006 Dec;16(12):1238-43. doi: 10.1111/j.1460-9592.2006.01982.x.
- Gamble JJ, McKay WP, Wang AF, Yip KA, O'Brien JM, Plewes CE. Three-finger tracheal palpation to guide endotracheal tube depth in children. Paediatr Anaesth. 2014 Oct;24(10):1050-5. doi: 10.1111/pan.12452. Epub 2014 Jun 23.
- Bloch EC, Ossey K, Ginsberg B. Tracheal intubation in children: a new method for assuring correct depth of tube placement. Anesth Analg. 1988 Jun;67(6):590-2. No abstract available.
- Weiss M, Knirsch W, Kretschmar O, Dullenkopf A, Tomaske M, Balmer C, Stutz K, Gerber AC, Berger F. Tracheal tube-tip displacement in children during head-neck movement--a radiological assessment. Br J Anaesth. 2006 Apr;96(4):486-91. doi: 10.1093/bja/ael014. Epub 2006 Feb 7.
- Jin-Hee K, Ro YJ, Seong-Won M, Chong-Soo K, Seong-Deok K, Lee JH, Jae-Hyon B. Elongation of the trachea during neck extension in children: implications of the safety of endotracheal tubes. Anesth Analg. 2005 Oct;101(4):974-977. doi: 10.1213/01.ane.0000169330.92707.1e.
- Kim JT, Kim HJ, Ahn W, Kim HS, Bahk JH, Lee SC, Kim CS, Kim SD. Head rotation, flexion, and extension alter endotracheal tube position in adults and children. Can J Anaesth. 2009 Oct;56(10):751-6. doi: 10.1007/s12630-009-9158-y. Epub 2009 Jul 29.
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
キーワード
その他の研究ID番号
- 12015C1043
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
IPD 共有時間枠
IPD 共有サポート情報タイプ
- STUDY_PROTOCOL
- SAP
- ICF
- CSR
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。